This paper proposes a novel current control scheme for vector-controlled induction machine (IM) drives in the overmodulation (OVM) range, with which the voltage utilization of the voltage-source inverter (VSI) can be maximized. In the OVM region, the original voltage reference is modified by changing its magnitude and angle, which causes the motor current to be distorted, resulting in a deterioration of the current control performance. To meet with this situation, the harmonic components in the feedback currents should be eliminated before being input to the PI current controllers. For this, a composite observer is applied to extract the fundamental and harmonic components from the distorted currents, which gives a good performance without a delay and the effect of a fundamental frequency variation. In addition, through a detailed analysis of the response of the PI current controllers in the OVM range, the effectiveness of using the composite observer is demonstrated. Simulation and experimental results for a 3-kW induction motor drive are shown to verify the validity of the proposed method.
Aziz, Mohd Junaidi Abdul;Klumpner, Christian;Clare, Jon
Journal of Power Electronics
/
v.12
no.2
/
pp.276-284
/
2012
AC/AC power conversion is widely used to feed AC loads with a variable voltage and/or a variable frequency from a constant voltage constant frequency power grid or to connect critical loads to an unreliable power supply while delivering a very balanced and accurate sinusoidal voltage system of constant amplitude and frequency. The load specifications will clearly impose the requirements for the inverter stage of the power converter, while wider ranges of choices are available for the rectifier. This paper investigates the utilization of a buck-type current source rectifier as the active front-end stage of an AC/AC converter for applications that require an adjustable DC-link voltage as well as elimination of the low-frequency common mode voltage. The proposed solution is to utilize a combination of two or more zero current vectors in the Space Vector Modulation (SVM) technique for Current Sources Rectifiers (CSR).
Most eco-friendly cars can adopt the concept of an integrated battery charger (IBC), which uses currently available motor drive systems. The IBC has a lot of strong points such as low cost and minimum space for the high voltage battery charger. On the other hand, it also has some defects caused by its structure. In this paper, the shortcomings of the conventional IBC for PHEVs with interior permanent magnet motors are discussed, and two advanced IBCs with improved performance are presented. Compared with the conventional IBC, the two advanced IBCs have plenty of strengths such as low common noise, high efficiency, simple sensing methods, etc. Then, the digital control algorithm is modified and a power loss calculation is carried out with simulation software. Finally, experimental results are provided to show the performance of the IBC systems.
The Transactions of the Korean Institute of Power Electronics
/
v.18
no.1
/
pp.110-116
/
2013
This paper proposes a current ripple reduction method to improve the control performance of B4 type inverter that is studied for cost-effective drive systems. B4 inverters employ only four switches and they have a center-tapped connection between the split dc-link capacitors and one phase of a three-phase motor or load. In the B4 topology, unbalanced three-phase voltages will be generated due to the dc-link voltage ripple. To solve this problem, this paper presents a voltage distortion compensation method that adjusts the voltage reference with the consideration of dc-link voltage ripple. The validity of the proposed method is verified by simulation and excremental results with an induction machine.
The Transactions of the Korean Institute of Electrical Engineers
/
v.36
no.4
/
pp.259-266
/
1987
In order to drive motor control system precisely, the motor is to be controlled by mmfs and current with sinusoidal waveforms. In this paper the Delta Modulation (DM) Technique is used for generating PWM pulse with sinusoidal waveform. However the motor currents yet contain odd harmonics due to leakage inductances, speed and exitation. To reduce harmonics, the parameter adaptive control method is introduced. That is, Req.C parameter of Delta Modulator is controlled adaptively by parameter adaptor. The adaptive signal is achieved by the difference between motor current and reference waveform, and this signal is converted to the voltage commend signal by adaptive mechanism. The test reslts show that this system is operated smoothly over a wide range of motor speed and motor current is controlled to be sinusoidal waveform adaptively.
The Transactions of the Korean Institute of Electrical Engineers
/
v.36
no.4
/
pp.267-272
/
1987
In this paper, field oriented control is applied to a 16 bit micro-processor Mc68000 controlled CSI fed induction motor servo drive. The control of induction motor using the principle of its is able to have the transient performance nearly to that of DC motors in the position control. The software and hardware for the Mc68000 is developed. The position control scheme consists of the field oriented control loop and te speed reference pattern generator. The digital computer simlation and experimental results are provided, close agreement between them is obtained.
The Transactions of the Korean Institute of Electrical Engineers
/
v.39
no.2
/
pp.164-174
/
1990
The improvement of linearized characteistics of induction motor control system with field oriented method is presented in this paper. A fully digitally controlled induction motor driver system based on the proposed linear control condition is described. The control system consists of IBM-PC/AT microcomputer, VSI PWM Inverter, and PI controller with softwave. By controlling the torque component, the rated flux component can be kept constant, even in the transient state. It is clearly confirmed by experiment that the improvement of the vector control condition is satisfactory. A simplified control model of an induction motor similar to the model for a separately excited DC motor drive system is obtained.
This paper is intended as an investigation of the interface between Neutral section insulators and pantograph interface. Neutral section insulators are installed at the boundary between AC catenary system and DC catenary system, which should provide electrical insolation between two different catenary systems and pass the trains without interruption. As the number of the pantographs installed on the train increased, which is necessary for the VVVF inverter drive trains introduced in recent years, there occurs an serious aspects of the interaction between pantographs and Neutral section insulators. These effects hinder the automatic switch operation of MCB(Main Circuit Breaker) after passing through the section insulators, and lead to the extra-ordinary wear of FRP insulator material of section insulators. Countermeasures in terms of the interface between the Neutral secton insulators and electric collection system of train are provided too.
This paper is proposed the optimal switching pattern of sleeted harmonic elimination (SHE PWM). It defined harmonic elimination band (HBE) to find the solution of Constant Voltage (CV), and sought all solutions which we are included HEB. Then, it calculated generalised klirr factor (GKF) by this solution and decided optimal switching pattern, used as initial conditions of newton raphson (NR) method to decide switching pattern at variable voltage (W). This strategy is applied to 1HP three phase induction motor. From the result, the validity of theoretical proposition can be verified.
Kim, Sang-Woo;Lee, Jae-Hun;Kim, Sang-Eun;Kim, Jong-Moo;Lee, Suk-Gyu
The Transactions of the Korean Institute of Electrical Engineers D
/
v.50
no.6
/
pp.266-271
/
2001
In this paper, a controller design for coreless linear synchronous motor is proposed. The designed controller is mainly composed of speed and current control, which are carried out by the high-speed digital signal processor(DSP). In addition the PWM inverter is controlled by space voltage PWM method. This system is implemented using by 32-bit DSP(TMS320C31), a high-integrated logic device(EPM940), and IPM(Intelligent Power Modules) for compact and powerful system design. The experimental results show the effective performance of controller for coreless linear synchronous motor.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.