• Title/Summary/Keyword: Inverter System

Search Result 2,790, Processing Time 0.03 seconds

Test bed for Advanced function of Smart Inverter and Results Based on Real-Time Simulation Platform (실시간 시뮬레이터 기반의 스마트 인버터 제어기능 시험 환경 구축 및 시험 결과)

  • Sim, Junbo;Ban, Minho;Lim, Hyeonok;Cho, Seong-Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.107-114
    • /
    • 2021
  • High penetration of renewable energy generators causes unnecessary investment for power system facilities. Especially with Korean government policies such as Renewable Energy 3020 and Inter-connection support Responsibility of KEPCO for 1 MW DERs, the applications of DER interconnection in distribution system have been increasing. To save the investment, smart control functions for DERs are required and the test bed for the inverters which have not been prepared are necessary to insure DER inter-connection stability. For this, test bed for advanced functions of a smart inverter has been constructed and the tests for necessary functions have been implemented. In this paper, the test bed and environment as well as specifications are introduced and the test results for the validation of the functions are analyzed.

A Study on the Frequency Control on the Induction Heating System Using Two Step Resonant Inverter (공진형 인버터를 이용한 2단 유도가열 시스템의 주파수제어에 관한 연구)

  • Yoo, Jae-Hoon;Shin, Dae-Cheul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.95-103
    • /
    • 2008
  • Proposed induction-heated system is innovative system which applied special high-frequency power circuit technique for thermal converse technique and IH(Induction-Heating) magnetic induction heating generated from induction-heated metallic package that is for distillation unit. In this occurs not burning, so that the working environment can be improved. This electromagnetic induction heating technique is used high frequency inverter. By using high frequency inverter high frequency alternative current (HFAC) in the range of [kHz] can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. In this paper are discussed action analysis and characteristics analysis of 1.5[kW]-Class half-bridge resonant inverter system and resonant metallic package. In addition, by using this system, how two step heating superheated steam generator is developed and application of system are also discussed.

A Single-Phase DC-AC Inverter Using Two Embedded Z-Source Converters (2대의 임베디드 Z-소스 컨버터를 이용한 단상 DC-AC 인버터)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1152-1162
    • /
    • 2011
  • In this paper, a single-phase DC-AC inverter using two embedded Z-source converters is proposed. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The output AC voltage of the inverter is obtained by the difference of output capacitor voltages of each converter. The output voltage of each converter take shape of the asymmetrical AC waveform centering zero voltage. Therefore, the proposed inverter can generate the same output voltage despite low VA rating L-C elements, compared to the conventional inverter using high DC voltage with AC ripple. To verify the validity of the proposed system, the PSIM simulation was achieved under the condition of rapid increase of DC source (110[V]${\rightarrow}$150[V]) and R-load (50[${\Omega}$]${\rightarrow}$300[${\Omega}$]). For controlling the voltage of the inverter system, the one-cycle controller was adopted. As results, the proposed inverter output the constant AC voltage (220[V]rms/60[Hz]) for all conditions. Also, the R-L load and nonlinear diode load were adopted for the proposed inverter loads, and we could know that the its output voltage characteristics were as good as the pure R-load. Finally, the RMS and THD of output AC voltage were examined for the different loads, input DC voltages and reference voltage signals.

High Precison Bearing Fault Detect System of Inverter Driven System Using Oversampled Current Signals (오버샘플된 전류신호를 사용한 인버터 구동형 전동기의 베어링 고장검출 시스템)

  • Kim, Nam-Hun;Kim, Min-Heui;Choi, Chang-Ho;Lee, Sang-Hoon;Choi, Keyng-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.506-508
    • /
    • 2007
  • In this paper, the induction motor bearing fault diagnosis system using current signals which are measured by over-sampling method is presented. In the case of inverter fed motor drive unlike line-driven motor drive, that make a lot of noise which can cause a wrong fault signals because of PWM(pulse width modulation) voltage. So, the current signals for fault diagnosis need very precise and high resolution information, which means this system demand additional hardware such as low pass filter, high resolution ADC system and so on to use fault diagnosis system. Therefore, the proposed over-sampling method is expected to contribute to low cost fault diagnosis system even though previous inverter fed motor drive without any additional hardware. In order to confirm the presented algorithms, various experiments for bearing faults are tested and the line current spectrum of each faulty situation using park transformation is compared with a FFT results.

  • PDF

Half-bridge Cascaded Multilevel Inverter Based Series Active Power Filter

  • Karaarslan, Korhan;Arifoglu, Birol;Beser, Ersoy;Camur, Sabri
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.777-787
    • /
    • 2017
  • A new single phase half-bridge cascaded multilevel inverter based series active power filter (SAPF) is proposed. The main parts of the inverter are presented in detail. With the proposed inverter topology, any compensation voltage reference can be easily obtained. Therefore, the inverter acts as a harmonic source when the reference is a non-sinusoidal signal. A 31-level inverter based SAPF with the proposed topology, is manufactured and the voltage harmonics of the load connected to the point of common coupling (PCC) are compensated. There is no need for a parallel passive filter (PPF) since the main purpose of the paper is to represent the compensation capability of the SAPF without a PPF. It is aimed to compensate the voltage harmonics of the load fed by a non-sinusoidal supply using the proposed inverter. The validity of the proposed inverter based SAPF is verified by simulation as well as experimental study. The system efficiency is also measured in this study. Both simulation and experimental results show that the proposed multilevel inverter is suitable for SAPF applications.

An analysis on the characteristic of inverter by the different factor both transformer and inductor (변압기 및 인덕터 구성에 따른 특성 분석)

  • An, Gyo-Sang;Im, Hui-Cheon;Kim, Sin-Seop;Hwang, In-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1348-1350
    • /
    • 2002
  • This paper describes an efficient comparison of the different factor both transformer and inductor. And also the 3 kW class inverter was fabricated for the analysis of the Photovoltaic(PV) power system's performance. The result of the performance of the 3 kW inverter showed that the total harmonics distortion(THD) was 3.19%, the conversion efficiency of the inverter was above 90 % at an over half load, respectively.

  • PDF

Developing the High Efficient Inverter Using Piezo Electronic Transformer (압전트랜스를 이용한 고효율 CCFL 인버터 시스템 설계)

  • Lee, Young-Kyu;Joo, Sung-Jun;Lee, Byung-Hoon;Hong, Soon-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1199-1201
    • /
    • 2002
  • Today, the ceramic transformer becomes widely used for the TFT LCD backlight inverter system thanks to its high efficiency and small size. In this paper, a high efficient inverter system for cold cathode flourescent lamp (CCFL) including PLL controller for tuning the PWM frequency to the frequency that the efficiency of the inverter system becomes maximum is proposed. The control IC implementing this feature will be released by Interpion Co. Ltd. in May 2002.

  • PDF

A Characteristic of commercial frequency unity Resonant PWM Inverter. (상용 주파수용 단일 공진 PWM 인버터의 특성)

  • Kim, Jong-Hae;Bae, Sang-June;Kim, Kyung-Sik;Moon, Chang-Soo;Ahn, Hang-Mok
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.318-320
    • /
    • 1996
  • This paper describes a new dc/ac inverter system, which makes use of parallel loaded high frequency resonant inverter consisting of full bridge, for achieving sinusoidal ac waveform. Because current throughout switch at turn-on is always zero in proposed inverter, low stress and low switching loss is achieved. Operating characteristic of proposed system is analyzed in per unit system using computer simulation. Output voltage of it include low harmonics and almost close tn sine wave.

  • PDF

A Study on the Design and the Analysis of Hybrid Inverter (하이브리드 인버터 설계 및 특성해석에 관한 연구)

  • 오진석;김윤식;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.99-106
    • /
    • 1995
  • PWM(Pluse Width Modulation) induction motor drives are being used in greater numvers through a wide variety of industrial and commercial applications. In this paper, a new speed control algorithm (hybrid algorithm) for induction motor drives that uses regular sampled PWM and harmonic elimination PWM is presented. The hybrid algorithm in implemeted on the computer to obtain solutions from the calculation equations of the width of the pulses and the firing angles for the selected harmonic elimination. this paper describes the time delay effects and the suitable compensating methods moreover, optical transmission system for driving signals is proposed and is compared with general trnasmission system. The hybrid inverter was tested with induction motor, and these test results are shown that this hybrid inverter closely approximates and exhibits many of the desirable performance characteristic distortions and eliminated the objectionable harmonics. Finally, detailed experimental investigation of the proposed hybrid scheme in presented.

  • PDF

A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter System using the DSP320F240 (DSP320F240을 이용한 PWM-Inverter구동 시스템에서의 전도노이즈 저감을 위한 스위칭 기법)

  • Park Hyun Seok;Park Kyu Hyun;Kim Lee Hun;Han Sung Yong;Won Chung Yuen;Kim Young Real
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.355-359
    • /
    • 2002
  • Much attention has been given to EMI effects created in variable speed ac drive system. Zero switching states of inverter control invoke large common mode voltage. This paper focuses on the switching techniques to mitigate common mode voltage. This paper proposes a common-mode voltage reduction method based on sinusoidal pulse width modulation in three phase PWM inverter system. By using three carriers wave displaced by 120 degrees, it is possible to eliminate a common mode voltage pulse In one control period. Simulation and experimental results show that common mode voltages In the proposed technique are reduced more than conventional technique.

  • PDF