• 제목/요약/키워드: Internal plate with holes

검색결과 11건 처리시간 0.025초

해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료 (Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture)

  • 정형진
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

SAS 반응기의 구조 안전성 평가 연구 (Study for Accessment of Structural Stability of SAS Reactor)

  • 이은우;정의동;김윤춘;김종배
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.43-49
    • /
    • 1995
  • Sasol Advanced Synthol Reactor was divided into two chambers by grid plate perforated with diffuser holes. The reactor has high stress level beacuse of membrane stress due to internal pressure, thermal stress due to temperature difference and local stress due to structural discontinuity at the juncture of grid plate and shell. Moreover, geometric nonlinear behaviors may appear in the grid plate because of pressure difference between two chambers. In order to survey the stress level and geometric nonlinear behaviors around grid plate, heat transfer analysis, linear static analysis and geometric nonlinear analysis were performed using NISA II developed by EMRC. This paper demonstrates the result of accessment for linear static and geometric nonlinear analysis under various load combinations.

  • PDF

저주파수 하의 TLCD 시스템의 오리피스 형상 효과 (Orifice shape effect of the TLCD system under a low frequency)

  • 임희창
    • 한국가시화정보학회지
    • /
    • 제12권1호
    • /
    • pp.30-34
    • /
    • 2014
  • Bluff bodies under the external periodic force vibrate at their own natural or forced frequency. Rectangular bodies or similar structures such as high-rise towers and apartments, and recently a well-cited application - offshore floating bodies, usually needs to reduce these vibrations for stability and the mode control. Therefore, this study is aiming to reduce or control the vibration of a structure by a passive control method, i.e., TLCD (Tuned Liquid Column Damper). Controlling a moving body with a TLCD based on a variety of the orifice shape has been preliminary studied. In order to get a proper control, an optimized study is made on the design of the orifice shape, which has internal plates with the holes. The results show the force acting on the body due to the periodic movement highly depends on the number of holes on the plate and the height of the water level. Therefore, the optimum shape of the orifice and the height of the water level should be confirmed by a series of experiments.

내부유공판을 사용한 각형 CFT 기둥-보 단순인장 접합부의 실험적 연구 (An Experimental Study on Simple Tension Connections for Square CFT Column to Beam Using Internal Plate with Holes)

  • 이성희;정헌모;양일승;최성모
    • 한국강구조학회 논문집
    • /
    • 제21권6호
    • /
    • pp.575-583
    • /
    • 2009
  • 최근 건물이 고층화 됨에 따라 건물의 중량감소와 시공의 효율성 확보를 위해 기존 S, RC, SRC 이외에 새로운 구조시스템이 적용되고 있으며, 그중에서도 CFT 구조는 우수한 구조성능과 시공성으로 많은 건설현장에 적용되어 왔다. CFT 구조는 접합부 구성시 보 플랜지 하중을 기둥과 반대편 보에 원활히 전달하기 위한 다이아그램이 필요하며 특히 기둥 좌우에 춤이 다른 보가 접합될 때 보의 하부 플랜지 하중전달을 위한 다이아프램 구성과 콘크리트 충전성 확보에 어려움이 있었다. 본 연구에서는 하부 보 플랜지 하중을 기둥에 원활히 전달하기 위해 CFT 기둥 내부에 유공판을 세로로 접합하는 형식의 접합상세를 제안하였다. 이 접합형식은 CFT 기둥 내부에 콘크리트가 충전될 때 콘크리트가 내부 유공판의 구멍을 관통하여 채워짐으로써 보 플랜지 하중전달에 콘크리트의 앵커효과를 이용하는 방법이며 유공판이 수직으로 설치됨으로써 콘크리트 충전성도 향상시킬 수 있다. 제안된 접합부의 구조거동분석을 위해서 내부유공판의 설치방향, 콘크리트의 충전 유/무, 내부유공판의 두께, 전단구멍의 개수등을 변수로하여 5개의 실험체를 제작하고 실험체의 실험적연구를 진행하였다.

미세 배선 성형을 위한 전주용 동도금액의 특성 (Characteristics of Copper Plating Solutions for Electroforming of Microcircuit)

  • 박해덕;장도연;강성군
    • 한국재료학회지
    • /
    • 제11권10호
    • /
    • pp.820-832
    • /
    • 2001
  • In order to obtain the basic data on the optimum conditions of electroforming process for fabricating the micro wiring pattern for plate type micro- motor core, characteristics of plating bath and properties of deposits were studied with various copper plating baths which contain sulfate, fluoborate, pyrophosphate and cyanide salt, respectively. Cathodic polarization, throwing power, internal stress, texture and surface morphology of deposits were observed. Throwing power of plating solution is deeply related to the polarization curves and the values are in the range of +20∼20%. The order of values ate as follows- pyrophosphate, cyanide, sulfate and fluoborate bath. Internal stresses of deposits are tensile in all of the copper plating bath. Thickness of the deposits plated at the center of holes has the highest value in the pyrophosphate bath and K factor, ratio of height and width of deposit, is 1.44. It was confirmed that the pyrophosphate bath was the best one for the electroforming of wire pattern.

  • PDF

하악골 과두경부 골절에 있어서 후하악부 절개법을 이용한 관혈적 정복술의 유용성 (Outcome of Open Reduction Via Retromandibular Approach for Mandibular Subcondyle Fracture)

  • 이형철;강동희;구상환;박승하
    • Archives of Plastic Surgery
    • /
    • 제32권6호
    • /
    • pp.739-743
    • /
    • 2005
  • Subcondylar fractures have generally been treated by intermaxillary fixation except in cases where there is an absolute indication for open reduction. The reason behind a less aggressive surgical approach lies on the inherent difficulties in manipulating fragments in such a small area at the risk of damaging facial nerves or vessels such as the internal maxillary artery. However, long-term follow-up studies showed that conservative treatment of subcondylar fractures results in disturbances of occlusal function, deviation of the mandible, internal derangement of the temporomandibular joint, and ankylosis of the joint. We carried out open reduction of dislocated subcondylar fractures in 14 patients from 2000 to 2004 by a retromandibular approach. After the reduction of fractured bone, two H-shaped miniplates with 6 holes were fixed with screws at the anterior and posterior surfaces of the subcondyle. The retromandibular approach allowed good access and easy manipulation of the subcondyle. Immediate relief from malocclusion and correction of mandibular midline shifting were observed in all patients. Late temporomandibular dysfunction and ankylosis were not observed. Open reduction with plate osteosynthesis made it possible to avoid IMF in 7 of the 14 patients. The present study shows that open reduction through this retromandibular approach can produce good outcome in adult patients with subcondylar fracture.

확장표면을 적용한 액체식 제습기에서 제습액 분배 특성에 관한 실험적 연구 (Experimental Study on Liquid Desiccant Distribution Characteristics at a Dehumidifier with Extended Surface)

  • 이민수;장영수;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.645-649
    • /
    • 2009
  • Liquid desiccant cooling technology can supply cooling by using waste heat and solar heat which are hard to use effectively. For compact and efficient design of a dehumidifier, it is important to sustain sufficient heat and mass transfer surface area for water vapor diffusion from air to liquid desiccant on heat exchanger. In this study, the plate type heat exchanger is adopted which has extended surface, and hydrophilic coating and porous layer coating are adopted to enhance surface wettedness. PP(polypropylene) plate is coated by porous layer and PET(polyethylene terephthalate) non-woven fabric is coated by hydrophilic polymer. These coated surfaces have porous structure, so that falling liquid film spreads widely on the coated surface foaming thin liquid film by capillary force. The temperature of liquid desiccant increases during dehumidification process by latent heat absorption, which leads to loss of dehumidification capacity. Liquid desiccant is cooled by cooling water flowing in plate heat exchanger. On the plate side, the liquid desiccant can be cooled by internal cooling. However the liquid desiccant on extended surface should be moved and cooled at heat exchanger surface. Optimal mixing and distribution of liquid desiccant between extended surface and plate heat exchanger surface is essential design parameter. The experiment has been conducted to verify effective surface treatment and distribution characteristics by measuring wall side flow rate and visualization test. It is observed that hydrophilic and porous layer coating have excellent wettedness, and the distribution can be regulated by adopting holes on extended surface.

  • PDF

볼트의 크기 및 판두께의 차이에 따른 고장력볼트 이음부의 역학적 거동에 관한 연구 (Mechanical Behavior of High-tension Bolted Joints with Varying Bolt Size and Plate Thickness)

  • 이승용;최준혁;김성훈;박철우
    • 대한토목학회논문집
    • /
    • 제26권1A호
    • /
    • pp.67-74
    • /
    • 2006
  • 장대교량 건설의 증가와 강교량의 합리화 추세에 따라 최근 후판 강재의 사용이 늘어가고 있다. 후판 부재의 현장이음에서는 M30 고장력볼트와 같은 대형볼트의 사용이 불가피하나 현재 국내 시방기준에는 대형볼트의 사용에 대한 규정이 없는 실정이다. 따라서 본 연구에서는 대형볼트인 M30 고장력볼트의 사용성을 검토할 목적으로 볼트의 크기와 부재의 판두께를 변수로 하여 릴렉세이션과 미끄러짐 거동을 시험적으로 분석하였다. 또한, 유한요소해석을 통하여 판두께의 차이에 따른 내부압축응력을 분석하였으며, 이를 볼트축과 볼트구멍 내벽에 부착한 변형률게이지로부터 얻어진 응력분포와 비교하였다. 그 결과 M30 고장력볼트를 사용한 경우에도 릴렉세이션은 10%를 초과하지 않았으며, 미끄러짐 계수도 시방기준을 초과하는 충분한 내력을 확보하는 것으로 나타나 사용상에 문제가 없는 것으로 판단된다.

한국인의 종골 크기 (The Size of Calcaneus in Koreans)

  • 김진수;조훈기;황새민;이근우;양기원;이경태
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.143-149
    • /
    • 2013
  • Purpose: Open reduction and internal fixation of calcaneal fracture using plate has been used. While numerous plates have been manufactured, most of the conventional plates are designed for westerners, realistically the size is larger for Korean. The domestic products, on the other hand, often have the undesirable screw holes and path. Therefore, we measured the radiologic parameter of Korean calcaneus for providing the plate and screw hole placements. Materials and Methods: We measured the outer lines and angles with over the 20 years old 291 females and 322 males. A: Length of inferior plane of calcaneus, B: Length of anterior plane of calcaneus, C: Length from line A to sinus tarsi, D: Length from line A to posterior point of posterior facet, E: Length from line A to calcaneal tuberosity, F: Length of posterior facet, G: Length from anterior point of line A to C, H: Length from line C to line D, a: Angle between A and B, b: Gissane angle, c: Bohler angle, d: Calcaneal pitch angle using Marosis m-view$^{(R)}$. Results: Mean A, B, C, D, E, F, G, H were 63.6, 26.4, 23.2, 43.7, 40.5, 26.9, 12.8, 18.1 mm. Mean a, b, c, d angle were 105.8, 122.4, 32.4, $20.5^{\circ}$. Male's calcaneus is significantly bigger than female's (p<0.001). Conclusion: AP calcaneus length 63.6 mm, maximal height 43.7 mm is considered to be helpful in making the Korean calcaneal plate.

상하 이형 다이아프램으로 보강된 2심 냉간성형 각형 CFT 기둥-보 접합부의 실험적 연구 (Experimental Study on Two-Seam Cold Formed Square CFT Column to Beam Connections with Asymmetric Diaphragms)

  • 오헌근;김선희;최성모
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.35-45
    • /
    • 2013
  • 콘크리트 충전강관 기둥은 우수한 구조성능에도 불구하고 폐단면이라는 특성 상 내다이아프램 형태의 접합부 제작이 어려워 시공성에 다소 문제가 있다. 본 연구에서는 이러한 문제를 해결하기 위해 미리 내다이아프램이 설치된 ㄷ형태의 부재 두 개를 용접하여 각형강관을 제작하는 방법을 제안한다. 접합부의 상부 다이아프램은 수평플레이트를, 하부는 수직 플레이트를 사용하였다. 본 연구는 제시된 접합부의 구조적 성능을 평가하기 위해 접합부 상 하부를 6개의 단순인장 실험과 실대 크기인 2개의 T형 기둥-보 접합부에 대해 반복가력 실험을 수행하였다. 단순인장 실험에서의 주요변수는 상부 다이아프램의 형태와 가력방향이며 하부 다이아프램은 수직 플레이트의 두께와 구멍 개수이고, 실대형 접합부의 변수는 가력방향이다. 실험결과 모서리 절삭형태는 큰 영향이 없었으며 강축방향이 약축방향보다 초기강성이 16~24% 높았다. 수직 플레이트의 구멍개수와 두께가 증가함에 따라 최대내력이 각 약 5% 증가하였다. 실대형 T형 접합부의 가력축에 따른 내력 차이는 크지 않았으며 보의 전소성모멘트에 도달할 때까지 안정적인 거동을 나타냈다.