Abstract

The concrete-filled tube column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. It suggests that pipe should be produced by welding two sides together where two shapes are joined after a channel is pre-welded onto the three sides in order to form an internal diaphragm. The upper diaphragm of the connection used the horizontal plate and the lower diaphragm used the Vertical plate. This research performed 6 monotonic tension experiments describing the connection upside and downside in order to evaluate the structural capability of the offered connection. And the cyclic loading experiment was performed about 2 T-Type column to beam connections. As to the experimental result edge cutting geometry, there was no big effect. An increase in the number of holes of the plate ultimate strength was increased by 5% and The thickness of the plate increases, the maximum strength was increased by 4%. T-Type connections until it reaches the plastic moment showed a stable behavior.

콘크리트 충전강관 기둥은 우수한 구조성능에도 불구하고 폐단면이라는 특성 상 내다이아프램 형태의 접합부 제작이 어려워 시공성에 다소 문제가 있다. 본 연구에서는 이러한 문제를 해결하기 위해 미리 내다이아프램이 설치된 ㄷ형태의 부재 두 개를 용접하여 각형강관을 제작하는 방법을 제안한다. 접합부의 상부 다이아프램은 수평플레이트를, 하부는 수직 플레이트를 사용하였다. 본 연구는 제시된 접합부의 구조적 성능을 평가하기 위해 접합부 상 하부를 6개의 단순인장 실험과 실대 크기인 2개의 T형 기둥-보 접합부에 대해 반복가력 실험을 수행하였다. 단순인장 실험에서의 주요변수는 상부 다이아프램의 형태와 가력방향이며 하부 다이아프램은 수직 플레이트의 두께와 구멍 개수이고, 실대형 접합부의 변수는 가력방향이다. 실험결과 모서리 절삭형태는 큰 영향이 없었으며 강축방향이 약축방향보다 초기강성이 16~24% 높았다. 수직 플레이트의 구멍개수와 두께가 증가함에 따라 최대내력이 각 약 5% 증가하였다. 실대형 T형 접합부의 가력축에 따른 내력 차이는 크지 않았으며 보의 전소성모멘트에 도달할 때까지 안정적인 거동을 나타냈다.

Keywords

References

  1. 김창수, 박홍근, 최인락, 정경수, 김진호(2010) 800MPa 강재 및 100MPa 콘크리트를 적용한 매입형 합성기둥의 구조성능, 한국강구조학회 논문집, 한국강구조학회, 제22권, 제5호 pp.497-509. Kim, C.S., Park. H.G., Choi, I.R., Chung, K.S., and Kim, J.H. (2010) Structural Performance of Concrete-encased Steel Columns using 800MPa Steel and 100MPa Concrete, Journal of Korean Society of Steel Construction, KSSC, Vol. 22, No. 5, pp.497-509 (in Korean).
  2. 최인락, 정경수, 김진호, 홍건호(2012) 이종강관을 사용한 고강도 CFT 합성부재의 구조성능, 한국강구조학회 논문집, 한국강구조학회, 제24권, 제6호, pp.711-723. Choi, I.R., Chung, K.S., Kim, J.H., and Hong, G.H. (2012) Structural Performance of High-Strength Concrete-Fillef Steel Tube Steel Columns using Different Strength Steels, Journal of Korean Society of Steel Construction, KSSC, Vol. 24, No.6, pp.711-723 (in Korean). https://doi.org/10.7781/kjoss.2012.24.6.711
  3. 김규석, 심종석, 한덕전, 최성모(1996) 콘크리트 충전 각 형강관기둥-H형강보 접합부의 탄소성 거동에 관한 연구, 대한건축학회 논문집, 대한건축학회, 제16권, 제1호, pp.417-421. Kim, K.S., Shim, J.S., Han, D.J., and Cho, S.M. (1996) An Experimental Study on the Elasto-Plastic Behavior of Concrete-Filled Steel Square Tubular Column to H-Beam Connections, Journal of the Architectural Institute of Korea, AIK, Vol. 16, No. 1, pp.417-421 (in Korean).
  4. 최성모, 윤여상, 김요숙, 김진호(2003) 이형 하부다이아프램으로 보강된 각형 CFT 기둥-보 접합부의 내진성능에 관한 연구, 한국강구조학회 논문집, 한국강구조학회, 제15권, 제5호, pp.579-589. Choi, S.M., Yun, Y.S., Kim, Y.S., and Kim, J.H. (2003) A Study on Seismic Performance for CFT Square Column-to-Beam Connections Reinforced with Asymmetric Lower Diaphragms, Journal of Korean Society of Steel Construction, KSSC, Vol. 15, No. 5, pp.579-589 (in Korean).
  5. 이성희 정헌모 양일승 최성모(2009) 내부 유공판을 사용한 각형 CFT기둥-보 단순인장 접합부의 실험적 연구, 한국강구조학회 논문집, 한국강구조학회, 제21권, 제6호, pp.575-583. Lee, S.H., Jung, H.M., Yang, I.S., and Choi, S.M. (2009) An Experimental Study on Simple Tension Connections for Square CFT Column to Beam Using Internal Plate with Holes, Journal of Korean Society of Steel Construction, KSSC, Vol. 21, No. 6, pp.575-583 (in Korean).
  6. 박찬면, 이광호, 이성희, 박용욱, 최성모(2006) 2심으로 제작된 각형강관 내다이아프램 접합부 개발에 관한 연구, 2006년도 대한건축학회 학술발표대회 논문집, 대한건축학회, 제26권, 제1호, pp.289-292. Park, C.M., Lee, K.H., Lee, S.H., Park, Y.W., and Choi, S.M. (2006) Study on Square Tubular internal diaphragm connection development with two-seam, Proceeding of Annual Conference of the Architectural Institute of Korea, Vol. 26, No. 1, pp.289-292 (in Korean).
  7. 최성모(2006) 중약진 지역인 우리나라에 적합한 보-기둥 접합부 개발에 관한 연구 -CFT를 중심으로-, 연구보고서 pp.1-255. Choi, S.M. (2006) A Research on Column-to-Beam Conne ction suitable in region of weak or moderate earthquake -In CFT connection-, Research Report, pp.1-255 (in Korean).
  8. Choi, S.M., Sang, Y.Y., Kim, D.K., Kim, Y.S., and Kim, J.H., (2006) Experimental study on seismic performance of concrete filled tubular square column-to-beam connections with combined cross diaphragm, Steel & Composite Structure.
  9. 박민수, 김희동, 이명재(2011) 충전성을 개선한 원형 CFT구조의 기둥-보 접합부 구조적 거동, 한국강구조학회 논문집, 한국강구조학회, 제23호, 제6호, pp.737-745. Park, M.S., Kim, H.D., and Lee, M.J. (2011) Structural Behavior of Beam-to-Column Connections of Circular CFT Structures Improving Concrete Filling, Journal of Korean Society of Steel Construction, KSSC, Vol. 23, No. 6, pp.737-745 (in Korean).
  10. 한국강구조학회(2012) 건축 강구조 표준접합상세지침. Korea Society of Steel construction (2012) Standard Details for Connection (Architecture Steel Structural) (in Korean).
  11. KS B 0801 (2007) 금속재료 인장시험편, 산업자원부 기술표준원. KS B 0801 (2007) Test Pieces for Tensile test for Metallic Materials, Korea Agency for Tech-nology and Standards (in Korean).
  12. KS B 0802 (2003) 금속재료 인장시험벙법, 산업자원부 기술표준원. KS B 0802 (2003) Method of Tensile test for metallic Materials, Korea Agency for Technology and Standards (in Korean).
  13. AISC (2005) Seismic provisions for structural steel buildings, American Institute of Steel Construction.

Cited by

  1. Seismic Evaluation of Welded-formed square Column-Beam Connection for External Diaphragm Stress path vol.26, pp.4, 2014, https://doi.org/10.7781/kjoss.2014.26.4.311
  2. 관통형 다이아프램을 갖는 조립형 콘크리트 충전 각형 합성기둥-보 접합부의 내진성능 vol.26, pp.5, 2013, https://doi.org/10.7781/kjoss.2014.26.5.431
  3. Behavior of End Plate Moment Connection with Through Bolts for Concrete Filled Composite Members with Thin-Walled Sections vol.32, pp.6, 2013, https://doi.org/10.7781/kjoss.2020.32.6.405
  4. Evaluation of Simple Tensile Strength of Internal Diaphragm According to Cross Sectional Shape vol.33, pp.3, 2021, https://doi.org/10.7781/kjoss.2021.33.3.171