• Title/Summary/Keyword: Internal Efficiency

Search Result 1,677, Processing Time 0.037 seconds

Energy Consumption of the Electric Vehicle and Internal Combustion Engine Vehicle for Different Driving Cases (주행 상황에 따른 전기차와 내연기관차의 에너지 소비 비교)

  • Kim, Jeong-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.8-13
    • /
    • 2020
  • In this paper, the electric vehicle (EV) and internal combustion engine vehicle (ICEV) are compared for different driving cases. The EV exhibits a lower powertrain efficiency when driven on the aggressive driving cycle than when driven on the moderate cycle. In particular, EV powertrain efficiency is low when the battery state of charge (SOC) is low, but ICEV efficiency increases when the driving cycle changes from the moderate cycle to the aggressive cycle. Based on these results, attempts can be made to increase EV powertrain efficiency. EV charging before the battery power drops to a low charging state can reduce energy consumption by 2.7% for an urban area. Furthermore, ECO driving has a more significant effect on EVs than on ICEVs.

Proposed Operating Parameters for Advanced Treatment Process using a Cilium Media BNR Process (섬모상담체를 이용한 고도처리공정의 운전인자 도출)

  • Ahn, Yoon Hee;Park, Chan Gyu;Ko, Kwang Baik;Lee, Kang Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.761-765
    • /
    • 2007
  • The study were conducted in order to investigate the effect of operating parameters including the internal recycle (nitrification return) rates, hydraulic retention times (HRTs) and temperature when using a cilium media method. The first experiment was for evaluating the effect of HRT (12 hr, 10 hr, 8 hr, 6 hr, 4 hr). The second experiment was for analyzing effect of internal recycle rate (100%, 200%, 300%, 400%). As a result of the first experiment, BOD was removed to 97~98% for 6~8 hr HRT. Effluent water quality was not significantly influenced with HRT within that range. However the nitrogen removal was sensitive to HRT. T-P removal efficiency was invariable at various HRTs. The average BOD removal efficiency was about 97% in spite of change of internal recycle rate while T-N removal efficiency was increased at the internal recycle rate of 100~200%, but invariable at the internal recycle rate of 200~300%.

The Effect of External R&D on the Innovation Efficiency : An Empirical Study of Manufacturing Industries in Korea (외부 R&D가 혁신 효율성에 미치는 영향 분석 : 국내 제조 산업을 중심으로)

  • Lee, Jiyoung;Kim, Chulyeon;Choi, Gyunghyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.4
    • /
    • pp.125-136
    • /
    • 2016
  • The external R&D, which includes the adoption of the external technology and knowledge in addition to the internal R&D, is one of important factors for the innovation. Especially for small and medium-sized enterprises (SMEs), the external R&D has been considered as a key factor to carry out the innovation more efficiently due to the limitations of their resources and capacities. However, most of extant studies related to external R&D have focused on analyzing the influence of external R&D on innovation outputs or outcomes. Only a few studies have explored the impact of external R&D on the innovation efficiency. This study therefore investigates whether the external R&D effects the industry's innovation efficiency and productivity. On this study, we used Korean manufacturing industry data of SMEs from 2012 to 2014 and employed a global Malmquist productivity analysis technique, which is based on the Data Envelopment Analysis (DEA), to assess the innovation efficiency and productivity. Innovation performances of external R&D group and internal R&D group are compared. Then, the sectoral patterns of both innovation efficiency and productivity are analyzed with respect to the technological intensity, which is introduced by OECD. The results show that the gap of innovation efficiency between external and internal R&D groups has gradually decreased because of the continuous improvement of the external R&D group's performance, while the external R&D group lag behind the internal R&D group. In addition, patterns of the innovation efficiency and productivity change were different depending on the technological intensity, which means that the higher the technological intensity, the greater the effect of external R&D.

Enhanced Internal Quantum Efficiency and Light Extraction Efficiency of Light-emitting Diodes with Air-gap Photonic Crystal Structure Formed by Tungsten Nano-mask

  • Cho, Chu-Young;Hong, Sang-Hyun;Kim, Ki Seok;Jung, Gun-Young;Park, Seong-Ju
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.705-708
    • /
    • 2014
  • We demonstrate the blue InGaN/GaN multiple quantum wells light-emitting diodes (LEDs) with an embedded air-gap photonic crystal (PC) which was fabricated by the lateral epitaxial overgrowth of GaN layer on the tungsten (W) nano-masks. The periodic air-gap PC was formed by the chemical reaction of hydrogen with GaN on the W nano-mask. The optical output power of LEDs with an air-gap PC was increased by 26% compared to LEDs without an air-gap PC. The enhanced optical output power was attributed to the improvement in internal quantum efficiency and light extraction efficiency by the air-gap PC embedded in GaN layer.

Development of a Monte Carlo Simulation Code (CALEFF) for Calibrating Thyroid Internal Dose Measurement and Detection Efficiency Calculation (갑상선 내부피폭선량 측정치 보정을 위한 몬테카를로 모의실험 코드 (CALEFF) 개발 및 검출효율 계산)

  • Ahn, Ki-Soo;Cho1, Hyo-Sung
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • According to the Para. 5 of Art 2 of the Korean Nuclear Safety Regulations, which was revised in 1999, internal dose assessment as well as external one should be performed by law for employees at a nuclear power plant from 2003, and their estimate errors should also be within 50%. Thus, more accurate internal dosimetry becomes important. Corresponding to such regulation revision, we are developing a more accurate thyroid-uptake internal dosimetric system and have developed a Monte Carlo simulation code, the so-called CALEFF, to calculate the detection efficiency of the dosimetric system. In this paper, we calculated detection efficiencies with various test conditions by using the CALEFF code and discussed their characteristics. We may use the detection efficiency calculated by the code in calibrating the thyroid internal dose from measured data.

  • PDF

유기 발광 다이오드의 광 추출 효율 개선을 위한 다양한 광학기능구조의 적용

  • Kim, Yang-Du;Kim, Gwan;Heo, Dae-Hong;Lee, Heon
    • Ceramist
    • /
    • v.21 no.1
    • /
    • pp.64-79
    • /
    • 2018
  • Recent years, OLEDs have been progressed intensively and been widely applied to Display and Lighting industry,Almost 100% internal quantum efficiency was achieved by developing new materials and structure optimization. However, external quantum efficiency was still low due to total internal reflection of light inside OLED devices and absorption of light at the surface of metal electrode. In order to improve external quantum efficiency of OLED devices, various kinds of optical functional structures were introduced to inside and outside of OLED devices to increase light extraction efficiency. In this paper, various efforts to apply optical functional structures in OLED devices were reviewed and way to improve light extraction efficency of OLED devices were discussed.

NUMERICAL STUDY ON THE CLOCKING EFFECT IN A 1.5 STAGE AXIAL TURBINE (1.5단 축류터빈에서의 Clocking 효과에 관한 수치적 연구)

  • Park, Jong-Il;Choi, Min-Suk;Baek, Je-Hyun
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.1-8
    • /
    • 2006
  • Clocking effects of a stator on the performance and internal flow in an UTRC 1.5 stage axial turbine are investigated using a three-dimensional unsteady flow simulation. Six relative positions of two rows of stator are investigated by positioning the second stator being clocked in a step of 1/6 pitch. The relative efficiency benefit of about 1% is obtained depending on the clocking positions. However, internal flows have some different characteristics from that in the previous study at the best and worst efficiency positions, since the first stator wake is mixed out with the rotor wake before arriving at the leading edge of the second stator. Instead of the first stator wake, it is found that the wake interaction of the first stator and rotor has a important role on a relative efficiency variation at each clocking position. The time-averaged local efficiency along the span at the maximum efficiency is more uniform than that at the minimum efficiency. That is, the spanwise efficiency distribution at the minimum efficiency has larger values in mid-span but smaller values near the hub and casing in comparison to those at the maximum efficiency. Moreover, the difference between maximum and minimum instantaneous efficiencies during one period is found to be smaller at the maximum efficiency than at the minimum efficiency.

Numerical Study on the Clocking Effect in a 1.5 Stage Axial Turbine (1.5단 축류 터빈에서의 Clocking 효과에 관한 수치적 연구)

  • Park, Jong-Il;Choi, Min-Suk;Baek, Je-Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.473-480
    • /
    • 2005
  • Clocking effects of a stator on the performance and internal flow in an UTRC 1.5 stage axial turbine are investigated using a three-dimensional unsteady flow simulation. Six relative positions of two rows of stator are investigated by positioning the second stator being clocked in a step of 1/6 pitch. The relative efficiency benefit of about 1% is obtained depending on the clocking positions. However, internal flows have some different characteristics from that in the previous study at the best and worst efficiency positions, since be first stator wake is mixed out with the rotor wake before arriving at the leading edge of the second stator. Instead of the first stator wake, it is found that the wake interaction of the first stator and rotor has a important role on a relative efficiency variation at each clocking position. The time-averaged local efficiency along the span at the maximum efficiency is more uniform than that at the minimum efficiency. That is, the spanwise efficiency distribution at the minimum efficiency has larger values in mid-span but smaller values near the hub and casing in comparison to those at the maximum efficiency. Moreover, the difference between maximum and minimum instantaneous efficiencies during one period is found to be smaller at the maximum efficiency than at the minimum efficiency.

  • PDF

A Study on the Radiated Noise the Prediction in the Pipe by Fluid Induced Vibration using the Radiation Efficiency and Pipe Surface Vibration (배관 표면진동과 방사효율을 이용한 배관 소음예측기법 연구)

  • Yi, Jongju;Park, Kyunghoon;Jung, Woojin;Seo, Youngsoo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.10
    • /
    • pp.763-769
    • /
    • 2014
  • This study is on the experiment and prediction of the pipe noise due to the internal fluid. The vibration of pipe external surface and noise in air were measured according to the internal fluid velocity and pipe type. In the experiment, the vibration and noise level of the straight pipe and rounded pipes show that the vibration and noise level are almost same. The 900 mitred pipe shows the high vibration and noise level. In the prediction of noise due to the internal flow, the method using the pipe surface vibration and radiation efficiency shows good agreement with experimental result.

Effect of HRT and Internal Recycle Ratio on Removal of Organic and Nitrogen in Swine Wastewater by Anoxic-Oxic Process Combined with Membrane (분리막이 결합된 무산소·호기 공정을 이용한 축산폐수처리에서 수리학적체류시간 및 내부반송율이 유기물 및 질소제거에 미치는 영향)

  • Whang, gye dae;Lee, bong hee;Lee, hyun duk
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.603-609
    • /
    • 2004
  • The objective of this study was to determine the optimal operation conditions in an anoxic oxic process to eliminate both organic and nitrogen matters in swine wastewater. For the purpose of this, the removal efficiency was evaluated with various HRTs and internal recycling ratio. During the whole 580 days of experiment, HRTs had been gradually decreased in an order of 20, 14, 12 and l0days, and the internal recycle ratio was kept at 20Q. So as to determine the effect of the internal recycle ratio on the nitrogen removal, the internal recycle ratio had been gradually increased from 20Q to 50Q while HRT was maintained at 12days. As a result, it was shown that the removal efficiency of organic matter was above 95% regardless of changing of HRTs. The average influent concentration of TCODcr and SCODcr were 24,854 mg/L and 18,920 mg/L, respectively. Average removal efficiency of TKN was shown to be nearly 98% when HRT was kept at 12days; however, the $NH_4{^+}-N$ concentration of effluent was shown to be increased when the loading rate of $NH_4{^+}-N$ was increased to $0.602 kgNH_4{^+}-N/m^3$-day by means of decreasing HRT to 10days. It was concluded that nitrogen loading rates should be more considered rather than organic loading rates in case of determining an optimal HRT. When gradually increasing the internal recycle ratio from 20Q to 50Q, the removal efficiency of organic matters and TKN were 96% and 98%, respectively so that no significant changes in removal efficiency was detected. However, when the internal recycle ratio was kept at 50Q, it was revealed that the $NO_3-N$ concentration of effluent seemed to drop and the average $NO_3-N$ concentration of effluent was around 52 mg/L.