• Title/Summary/Keyword: Intelligent Equipment

Search Result 451, Processing Time 0.042 seconds

Intelligent Collision Prevention Technique for Construction Equipment using Ultrasound Scanning (초음파 스캐닝을 활용한 지능형 건설기계 충돌방지 기술)

  • Lee, Jaehoon;Hwang, Yeongseo;Yang, Kanghyeok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.5
    • /
    • pp.48-54
    • /
    • 2021
  • According to the Ministry of Employment and Labor's statistics on occupational fatalities in South Korea, more than half of the fatalities in the past five years have occurred in the construction industry. The stuck-by and caught-in-between accidents associated with construction equipment is the major source of fatalities from construction sites. In order to prevent such accidents in construction sites, the government has spent lots of efforts including proposing the "special law on construction safety" and encouraging the implementation of new technology for accident prevention. However, numerous accidents are still occurred at construction sites and further efforts are still required. In this manner, this study developed a collision prevention technique that can prevent collision between equipment and worker by recognizing location and type of the nearby objects through ultrasound scanning. The study conducted a pilot experiment and the analysis results demonstrate the feasibility of achieving high performance in both object recognition and location estimation. The developed technique will contribute to prevent collision accidents at construction sites and provide the supplemental knowledge on developing automated collision prevention system for construction equipment.

A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence (인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구)

  • Yeon Jin, Im;Ho Seong, Hwang;Dong Hyun, Kim;Ho Chul, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.

The Development of Intelligent Blocking Stand-by Power from Electronic Products (압연기 베어링 진동 신호의 카오스적 거동 가전제품에서 지능형 대기전력 차단회로 개발)

  • 배영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.631-633
    • /
    • 2000
  • Modern consumer electronic products like TV, VCR etc, offer users the convience of switching the equipment on and off via a remote control handset. When this type of equipments is switched off, it is said to be in standby mode. In this paper, We proposed that the method of the blocking standby power Son in industrial product including electronic and electronic appliauces. This method is perfectly blocking the standby power of electrical circuit.

  • PDF

Interoperability Test of the Digital Substation using IED Conformance Testing System (IED 적합성 시험장치를 이용한 디지털 변전소 상호운용성 시험)

  • Lee, N.H.;Jang, B.T.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.11-12
    • /
    • 2007
  • In order to verify a digital substation based on IEC 61850, KEPRI in charge of POWER IT project related to SAS has constructed IED conformance testing system, which consists of HMI, IED (Intelligent Electronic Device), network equipment, V/I generator, and performed the interoperability test between two IEDs made by other vendors. The test was proceeded based on SCL and with system integrated tools

  • PDF

A Study on the standardization of ETCS (Focused on RF) (자동요금징수시스템(ETCS) 표준화 연구(주파수방식을 중심으로))

  • Kwon, Han-Joon;Lee, Ki-Hyun;Kim, Yong-Deak
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.3
    • /
    • pp.62-73
    • /
    • 2008
  • In this paper, domestic standard revision plan of dynamic frequency method which is used both in unmanned automatic toll collection system and manned collection system of the express highway is presented. For such ETCS, the infrared rays (870 nm) of active frequency method and the frequency integrated method (5.8 GHz) are adopted and extended to be operated to the all around the Toll Gate. This standardization plan is based on inter connection reference model between OSI (Open System Interconnection) in process of ITS short range radio communication standardization of 5.8 GHz bandwidth to support traffic information and control system service, and the derived revision plan by starting from physical layer which support interoperability for multiple access between RSE (Road Side Equipment) and OBE (On Board Equipment), in which is categorized into physical layer, data link layer, and application layer. In case of radiation power, existing standard is divided by class1 (within 10 m) and Class2 (within 100 m) according to transmission lengthwhile it is operated with just single standard 'Class1' because of notification of Ministry of Information and Communication in 2004. In the case of the limitation value of incident power in communication area, considering operation plan of ETCS that is on actuality operation the measurements are reflected to the standard. In other wort this paper proposed the improvement standard of incident power, pseudo response in the communication area and radiated power in order to secure stability and compatibility among operator systems about the needed part on ETCS operation.

  • PDF

Study on Estimation of Unmanned Enforcement Equipment Installation Criteria and Proper Installation Number (무인교통단속장비 설치 판단 기준 및 설치대수 산정 연구)

  • So, Hyung-Jun;Kim, Yong-Man;Kim, Nam-Seon;Hwang, Jae-Seong;Lee, Choul-Ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.49-60
    • /
    • 2020
  • The number of traffic control equipment installed to prevent traffic accidents increases every year due to continuous installation by the National Police Agency and local governments. However, it is installed based on qualitative judgment rather than engineering analysis results. The purpose of this study was to present additional installations in the future by presenting the installation criteria considering the severity of accidents for each road type and calculating the appropriate number of installations. ARI indicators that can indicate the severity of traffic accidents were developed, and road types were classified through analysis of variance and cluster analysis, and accident information by road type was analyzed to derive ARI of clusters with high traffic accident severity. The ARI values required to determine the installation of equipment for each road type were presented, and 5,244 additional installation points were analyzed.

A study on the new developmental direction for Intelligent Network Service (지능망서비스의 발전방향에 관한 연구)

  • 박민수;최수길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.43-49
    • /
    • 2000
  • That modem society is an information society, information society has placed a high value on information and knowledge. Therefore, modem civilization depends largely on information and knowlege so the most valuable sources of all intelligence activities. This paper was studied on the new developmental direction for intelligent network service. The results of this study is as follow: first, intelligent network service must be systematic development. Second, intelligent network service must be promoted, presenting the development and establishment direction in future society. Third, intelligent network service must be able to unify ail the networks. Fourth, intelligent network service must be development for customers. Fifth, the cost of intelligent network service is determined by Telecommunication Reguration Commission. Sixth, the number system of intelligent network service must be accomplished by number system for future

  • PDF

Plans for the Integrated Operation of Intelligent Service Facilities (지능화시설의 통합운영 방안)

  • YIM, Du-Hyun;PARK, Jeong-Woo;NAM, Kwang-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.1
    • /
    • pp.127-136
    • /
    • 2017
  • U-City laws are divided into three categories: intellectual laws, information superhighway laws, and integrated operation center laws. Previous studies have suggested that efficient infrastructure operation and management is necessary in Ubiquitous-City (U-City). However, infrastructure is often interpreted differently by different laws. The purpose of this study was to plan for the integrated operation of intelligent service facilities by comprehensively analyzing the law system of domestic intelligent service facilities and problems in operation and management based on this critical mind. For this, present conditions and problems of intelligent service facilities were found through interviews with people who are in charge of the law system and other practitioners. The necessity of integrated use, including city information generated from intelligent service facilities and installment locations, has been demonstrated. Government ministries and local governments have established various information systems using ICT and U-City laws that specify integrated management and operation, but do not clearly specify definitions for the specific responsibility and authority for main agents participating in facility operation. A system is needed to smoothly mediate the relevant divisions so that they can use installed equipment simultaneously for efficient operation in generating city information. This objective of this study was to prepare a unitary law system for efficient installment and management of intelligent service facilities by establishing a logically linked relationship among the relevant laws and regulations. This will provide a foundation for a management system that has an integrated linkage of intelligent service facilities.

A Traffic Simulation Model Verification Method Using GPS Equipment (GPS를 활용한 교통 시뮬레이션 모형 검증)

  • Hu, Hyejung;Baek, Jongdae;Han, Sangjin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.5
    • /
    • pp.62-69
    • /
    • 2012
  • Traffic simulation models have been used for assessing various transportation strategies. Through comparing results from a simulation model and real field data, researchers try to show how close the model can reproduce the real world traffic. This model verification step is one of the most essential tasks in modeling procedure. Traffic counts and speeds have been frequently used for the verification or validation. Authors modeled severe PM peak bottleneck situation on the I-40 corridor in Raleigh, North Carolina using DYNASMART-P, a mesoscopic traffic simulation tool and verified the model. NCDOT has Traffic Information Management System which has archive capability for the traffic speeds on the I-40 corridor. However, the authors selected travel time as the field measure for model verification and collected the data using a GPS equipment because the speed data from NCDOT speed detectors are spot speeds which are not appropriate for comparison with link average speed from the simulation model. This paper describes the GPS field data collection procedure, the model verification method, and the results.

A Wavelet-based Profile Classification using Support Vector Machine (SVM을 이용한 웨이블릿 기반 프로파일 분류에 관한 연구)

  • Kim, Seong-Jun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.5
    • /
    • pp.718-723
    • /
    • 2008
  • Bearing is one of the important mechanical elements used in various industrial equipments. Most of failures occurred during the equipment operation result from bearing defects and breakages. Therefore, monitoring of bearings is essential in preventing equipment breakdowns and reducing unexpected loss. The purpose of this paper is to present an online monitoring method to predict bearing states using vibration signals. Bearing vibrations, which are collected as a form of profile signal, are first analyzed by a discrete wavelet transform. Next, some statistical features are obtained from the resultant wavelet coefficients. In order to select significant ones among them, analysis of variance (ANOVA) is employed in this paper. Statistical features screened in this way are used as input variables to support vector machine (SVM). An hierarchical SVM tree is proposed for dealing with multi-class problems. The result of numerical experiments shows that the proposed SVM tree has a competent performance for classifying bearing fault states.