• Title/Summary/Keyword: Integrated Operation System

Search Result 1,297, Processing Time 0.031 seconds

An Integrated Sewer Management System using Web Based Predictive Spatial Information System (웹 기반의 공간정보예측시스템을 이용한 통합적 하수도 관리 시스템의 개발 및 적용)

  • Kim, Joon-Hyun;Han, Young-Han
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.1
    • /
    • pp.73-83
    • /
    • 2001
  • Web based integrated sewer management system was developed for the analysis of sewer flow and for the optimal operation of sewer works using ArcView and SWMM. SWMM and ArcView were dynamically linked together using Avenue in order to construct user-friendly information management system. The developed system was applied to the residential area in Choonchun city to verify its utilities. All the relevant field data were analyzed on the basis of the developed system, and the modeling of sewer flow was implemented using RUNOFF, EXTRAN, TRANSPORT in SWMM. This system is now in the process of connection to the management system of stormwater, surface and subsurface environment in order to develop an integrated environmental management system. Futhermore, this system will be a critical part of overall control system of sewer works including sewer network and wastewater treatment plant. As this system can provide comprehensive prediction of flow and pollution profiles, it could serve as a tool not only for the optimal management, but also for the decision support system to examine the efficiency of planning and implementation of sewer projects.

  • PDF

A Study on the Method Improvement of the Integrated Railway Safety Audit System through the Analysis of Results (철도종합안전심사 결과 분석을 통한 효율적 심사방안 연구)

  • Song, Bo-Young;Song, Byeong-Ho;Oh, In-Tack
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2503-2516
    • /
    • 2011
  • According to Railway Safety Act, Korea Transportation Safety Authority (KOTSA) has been entrusted with 'Integrated Railroad Safety Audit (IRSA) and has implemented the safety audit to the railroad operation agencies such as Korea Railroad (KORAIL) and the railroad facility management organization such as the Korea Rail Network Authority (KR Network). The target of IRSA is to establish the effective rail safety management system and to raise the safety level of the railroad operation and facility agencies by checking synthetically their performance of safety duties with sincerity according to the Railway Safety Act. Even though newly introduced IRSA is conducted smoothly, it is necessary to study the methodology and criteria of the state's safety audit system. The purpose of this paper is to improve the efficiency of IRSA by the comparative research between IRSA and other similar safety audit system and to establish the consecutive improvement concept of IRSA. Second purpose is to confirm the effectiveness of IRSA by the analysis of the relationship between audit results and the safety level of the rail operation agencies.

  • PDF

Development of Optimal Thermal Transfer Calculation Algorithm by Composition of Thermal Transfer Mechanism among Integrated Energy Operators (집단에너지 사업자간의 열연계 메커니즘 구성에 의한 최적 열연계 산정 알고리즘 개발)

  • Kim, Yongha;Kim, Seunghee;Hyeon, Seungyeon
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.57-66
    • /
    • 2017
  • Since the heat is not as fast as the electric power and the loss is relatively large compared to the electric power, it is not realistic to operate the thermal transfer system with on operation center like electric power trading. In the case of the Korea District Heating Corporation, where all the thermal transfer are currently being made, only two or four adjacent heat-generating power plants are being the heat trading. Therefore, In this paper, we concluded that it is appropriate to divide the integrated operation center for heat trading into several regions, to operate the hub integrated operation power plant in each region to reflect the characteristics of the heat medium and proposed the thermal transfer mechanism among integrated energy operators. Then, we have developed an algorithm that can optimize the heat transaction for the proposed mechanism and applied it to the actual operators to verify the usefulness of the proposed algorithm.

FIELD EXPERIENCE OF PORTABLE SMPS+C NANO PARTICLE SIZER

  • Gerhart, Ch.;Grimm, H.J.;Heim, M.
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.47-48
    • /
    • 2003
  • This new family of portable real time SEQUENTIAL MOBILITY PARTICLE COUNTER and SIZER (SMPS+C) is designed for mobility and easy field use. An integrated battery assures hours of operation, a data logger system storage of all optioned results and a user friendly powerful software easy operation. This technology not only simplifies the SMPS operation, but it permits new on site application monitoring up to a remote wireless telephone operation. (omitted)

  • PDF

Development of the Prototype of Integrated Information System for Conflation and Utilization of Land and Building Information (토지·건물정보의 융복합 및 활용을 통한 통합정보시스템 프로토타입 개발)

  • Park, Woo-Jin;Jeong, Dong-Hoon;Park, Jung-Hee
    • Journal of Cadastre & Land InformatiX
    • /
    • v.46 no.2
    • /
    • pp.341-356
    • /
    • 2016
  • Land information and building information have highest utilization and importance in real estate and city administration area. However, providing integrated information service was difficult because conflation and integrative utilization was not easy. In this study, necessity of integrated information system, direction of integration, method of conflation and design of integrated system for land and building information are presented. In addition, the prototype system is developed and possibility of application of integrated information is proposed. For this purpose, current situation of management of land and building information was analyzed. Based on the analysis, matching and conflation processes among spatial and attribute data were applied to land and building information. Using integrated land building information DB, integrated information system and functions were designed and the prototype system was constructed. At last, information service examples in real estate and city administration area were suggested through system operation by LX.

An Empirical Study on the Business Performance Determinants According to Years of Operation in Domestic New Ventures (국내 벤처기업의 업령(業齡)에 따른 성과 결정요인)

  • Lee, Sang-Cheon;Go, Bong-Sang;Yong, Se-Jung
    • IE interfaces
    • /
    • v.17 no.spc
    • /
    • pp.11-19
    • /
    • 2004
  • The purpose of this study is to identify the determinants of new venture performance according to years of operation in the view of integrated research framework. We propose the integrated new ventures performance model which is composed of entrepreneur, organization/resources, industrial environment, strategy/foundation process and availability of supporting systems as corresponding variables to new ventures performance. The determinants of new venture performance according to years of operation are identified through the multi-variate statistical analysis such as moderating regression analysis with the data gathered from 110 executives of venture companies. For internal variables, entrepreneur's managerial ability and technical expertise and employee's ability affect venture's performance increasingly as years of operation increases but resource procurement ability affects decreasingly. Related to external variables, years of operation plays positive moderating role on market size growth and supporting system availability, but negative role on government venture policy for venture performances. Though this study has limitation of small sample, limited questionnaire and performance measure, it has managerial contribution of identifying determinants of new venture performance according to years of operation.

The Development of a Shop Floor-Centered Information System for the Integration of Design and Manufacturing Data (생산 현장 중심의 설계/생산 통합 정보 시스템 개발)

  • Han K. H.;Park C. W.;Oak J. S.;Kim K. S.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.4
    • /
    • pp.237-243
    • /
    • 2005
  • To increase the productivity and efficiency of an enterprise, all relevant product information should be provided to shop floor workers timely and in a unified form because shop floor workers are final consumers of most accumulated information generated from various departments of an enterprise. But, most existing enterprise information systems have an emphasis upon providing design/manufacturing information to office workers. Proposed in this study is the development of integrated design/manufacturing information system focused on providing cohesive information required to shop floor activities. For developing integrated information system, the functional requirements at the shop floor are identified and analyzed. Based on the extracted functional requirements, object-oriented system design and implementation is conducted. By using this system, shop floor workers can use all relevant information required to their daily operation in a integrated and unified form.

A New Controllable Active Clamp Algorithm for Switching Loss Reduction in a Module Integrated Converter System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.465-471
    • /
    • 2014
  • This paper proposes a new switching algorithm for an active clamp snubber to improve the efficiency of a module integrated converter system. This system uses an active clamp method for the snubber circuit for the efficiency and reliability of the system. However, the active clamp snubber circuit has the disadvantage that system efficiency is decreased by switch operating time because of heat loss in resonance between the snubber capacitor and leakage inductance. To address this, this paper proposes a new switching algorithm. The proposed algorithm is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time. Also, the snubber switch is operated at zero voltage switching by turning on the snubber switch before main switch turn-off. Simulation and experimental results are presented to show the validity of the proposed new active clamp control algorithm.

A Study on the Oil-Jet Lubrication Characteristics of a Motor-Integrated High-Speed Spindle System with $\phi$65mm$\times$25,000rpm (오일제트윤활방식의 25,000rpm급 모터내장형 고속주축계의 윤활특성에 관한 연구)

  • 이용희;김석일;김태형;박보선
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.59-64
    • /
    • 1998
  • In this study, a motor-integrated high-speed spindle system with $\psi$65mm $\times$ 25,000rpm is developed by introducing the oil-jet lubrication method, ceramic angular contact ball bearings, a built-in motor and so on. And oil-jet lubrication experiments fur evaluating the system performance are performed under various operation conditions. Especially, in order to establish the oillet lubrication conditions related to the development of a high-speed spindle system, the effects of oil supply rate and rotational spindle speed are investigated on the temperature rise, temperature distribution, motor current and so on.

  • PDF

An Experimental Study for Evaluating Performance of Radiant Floor Cooling System Integrated with Dehumidification (제습기능이 통합된 바닥복사 냉방시스템의 용 가능성에 관한 실험적 연구)

  • 이상엽;황석호;김가현;이승복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.143-152
    • /
    • 2002
  • It is critical for radiant floor cooling system using Ondol to cause condensation on a floor surface. To solve this problem, a radiant floor cooling system integrated with dehumidification was proposed and evaluated in terms of its applicability and prevention of condensation. Therresults show that the proposed system of radiant floor cooling integrated with dehumidification properly maintained the indoor setpoint temperatures and prevented the condensation on a floor surface. To achieve more stable indoor temperatures and humidity control, a further study for the operation of dehumidification panel will be needed.