• Title/Summary/Keyword: Insulation Efficiency

Search Result 316, Processing Time 0.21 seconds

Development of Live-line Insulator Tester and Its Application to 154kV Power Lines - Part 1 : Tester Development (활선애자점검기의 개발 및 154kV 선로에의 적용 - 제1부 : 점검기 개발)

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak;Oh, Ki-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.83-88
    • /
    • 2010
  • A new live-line insulator tester was developed to detect faulty insulators in 154kV power transmission lines. This paper is the first part of the two-part paper and deals with its tester development. The developed tester has the following characteristics. First, it automates parts of the insulator inspection process by using a sensor and an actuator, and secondly, it sustains its weight by itself, not by a lineman. Finally, it measures the insulation resistance of an insulator together with its distribution voltage to provide more information for its analysis and diagnosis. These leads to the improvement of its operation efficiency, measurement reliability and usability. Its effectiveness was validated by live-line field tests in actual power lines.

The new lightning detection system of KEPCO Lightning Detection & information Network (한전의 새로운 낙뢰측정 네트워크 KLDNet)

  • Woo, J.W.;Kwak, J.S.;Shim, E.B.;Won, B.J.;Moon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.83-84
    • /
    • 2006
  • Lightning induced faults accounts for more than 66% at the transmission lines of KEPCO. The lightning causes damages to power system equipments including transmission line, the shut down of electricity and the electro-magnetic interference. Because of this reason, we need the real time lightning information for the optimal operation of power system. And, it is required to obtain and accumulate the lightning current parameters for the insulation design. A lightning detection system, LPATS, has been operated since 1995 in KEPCO. For the improved detection efficiency, we had in stalled the new lightning detection network named as KLDNet in 2005. Also, we had developed the new software for the lightning parameters analysis and real time information service on the WEB. In this paper, we would like to introduce about the new system.

  • PDF

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

An economic evaluation of heat exchanger for heat recovery ventilation (폐열회수환기를 위한 열교환장치의 경제성 평가)

  • Park, Yong-Hyo;Lee, Sang-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.241-244
    • /
    • 2008
  • Recently, The high Air-Tightness and high heat insulation for building construction cause a ventilation air volume deficiency. Also, Worldwide high energy price is strongly urging to economize the air conditioning energy. Therefore Heat Recovery Ventilation is used for the satisfaction of ventilation air volume and building energy saving. Accordingly, this study dose the heat exchanger performance evaluation and economic efficiency evaluation of Heat Recovery Ventilation. And, we wish to make a basic study about HRV System application of HVAC System and Multi System Air-conditioning.

  • PDF

A Protection of Substation Equipment Applying Underbuilt Ground Wire and Guy Wire (Underbuilt Ground Wire와 Guy Wire를 이용한 변전소 기기 보호에 관한 연구)

  • Kim Jae Kwan;Lee Jong Beom;Cho Han Goo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.610-612
    • /
    • 2004
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about $50\%$. Therefore, the insulation design is important to decrease the damage of the facility and to increase the reliability of electric power system. This paper describes the protective method of substation equipments using the Underbuilt Ground Wire and the Guy Wire. This would not only reduce backflashover possibility but also minimize crest and duration of surges entering the substation. EMTP is used to analyze the efficiency of the proposed methods.

  • PDF

A Reliability Test for Pb-Free Plating Solution and its Deposit (Pb-Free 도금용액 및 피막의 신뢰성평가)

  • Hur, Jin-Young;Koo, Suck bone;Lee, Hong-Kee
    • Clean Technology
    • /
    • v.11 no.3
    • /
    • pp.153-164
    • /
    • 2005
  • This study found a reliable evaluation for four kinds of pb-Free plating solutions and it's layers, through pure Sn, SnAg, SnBi and SnCu. These four kind of solutions are widely used to pb-Free plating. Hull-cell, Harring-blum, coverage, throwing power, current efficiency, stability, life-time, composition, hardness, roughness, abrasion, scratch, solderability, corrosion, contact angle, morphology, SIR(Surface insulation resistance) and Whisker test were experimented. Also, Using ICP, XRF, FE-SEM, EDS, temperature/humidity chamber, solderability tester, hardness tester, roughness tester, abrasion tester, salt spray tester, contact angle tester, SIR tester, and microscope. In this paper could be shown the systematic and various analysis for reliability about four kinds of pb-Free plating solutions, processes and it's deposit surface.

  • PDF

An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type (주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석)

  • Choi, Gyeong-Seok;Jeong, Young-Sun;Kang, Jae-Sik;Lee, Seung-Eon;Jeong, Yeong-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

The Stability Assessment of Backfill Materials and External Loads in Pre-Insulated District Heating Pipes (지역난방 열배관의 외부작용력 및 되메움재의 안정성 확보에 관한 연구)

  • Kim, Jin-Man;Choi, Bong-Hyuck;Ko, Hyun-Il
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.656-661
    • /
    • 2009
  • In this study, theoretical analysis and evaluation tests were performed to assess the pipe stability against compaction equipments and vehicle loads when conventional construction criteria for pre-insulation heating pipes are applied and the alternative material, crushed sand, are used for backfills. The research outcomes shows that (1) the conventional code criteria for pre-insulated heating pipes is well established to support compaction equipments and vehicle loads, (2) the crushed sands as an alternative is usable as backfill materials for pre-insulated heating pipes based on the suitability evaluations of various types of pipes, and (3) the crushed sand agree well with the design consideration of pre-insulated heating pipes construction in the points of economical efficiency and construction criteria.

  • PDF

Operating Characteristics of $1Nm^3/hr$ class Natural Gas Fuel Processor for Residential Fuel cells (가정용 연료전지 $1Nm^3/hr$급 천연가스 연료처리장치의 운전 특성)

  • Shin, Jang-Sik;Shin, Seock-Jae;Lee, Seung-Young;Yang, Hye-Kyong;Sung, Bong-Hyun;Kim, Doo-Hoon;Park, Jong-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.19-22
    • /
    • 2007
  • In this study, we investigated operating characteristics of natural gas fuel processor for polymer electrolyte membrane fuel cells (PEMFCs). The fuel processor consists of a natural gas reformer, a water-gas shift reactor, a heat-exchanger and a burner, in which the overall integrated volume is exactly(exceptionally) small, namely, about 10L except outer insulation. The producted hydrogen is $1Nm^3/hr$ and the maximum thermal efficiency is ${\sim}76%$(low heating value) at full operating load. A compact and highly efficient $1Nm^3/hr$ class natural gas fuel processor was developed at UNISON is an advantage for application in residential PEMFCs co-generation systems.

  • PDF

Properties of Epoxy Based Nanocomposites and their Application to High Efficiency Electric Materials (나노복합체를 이용한 고효율 전기소재 설계 기술)

  • Lee, Sang-Heon;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.45-47
    • /
    • 2011
  • Recently, research works for electrical properties on the elastic epoxy have been also progressing to diagnose insulation materials by development of measure technology. The epoxy which specially applied for high voltage instruments have required for the electrical, mechanical and thermal properties. Nanocomposites were made from insulating material epoxy resin using for power transformer as varying g amount of addition of SiO2, we found the change of physical characteristics of nanocomposites by using SEM and XRD. To investigate the electrical properties according to the amount of addition and temperature, tested insulting breakdown in silicon oil. As the result of insulting breakdown testing, the insulting breakdown strength increased according to change of the amount of addition.