• 제목/요약/키워드: Installation method

검색결과 3,278건 처리시간 0.025초

지오그리드의 시공시 손상 및 크리프 복합효과에 대한 실험적 연구 (An Experimental Study on the Combined Effect of Installation Damage and Creep of Geogrids)

  • 조삼덕;이광우;오세용;이도희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.561-568
    • /
    • 2005
  • The factors affecting the long-term design strength of geogrid can be classified into factors on creep deformation, installation damage, temperature, chemical degradation and biological degradation. Especially, creep deformation and installation damage are considered as main factors to determine the long-term design strength of geogrid. Current practice in the design of reinforced soil is to calculate the long-term design strength of a reinforcement damaged during installation by multiplying the two partial safety factors, $RF_{ID} and RF_{CR}$. This method assumes that there is no synergy effect between installation damage and creep deformation of geogrids. Therefore, this paper describes the results of a series of experimental study, which are carried out to assess the combined effect of installation damage and creep deformation for the long-term design strength of geogrid reinforcement. The results of this study show that the tensile strength reduction factors, RF, considering combined effect between installation damage and creep deformation is less than that calculated by the current design method.

  • PDF

IEC 60364기반 건축전기설비 점검기법 개발을 위한 현장실태 조사 (An Investigation into the Actual Condition of Electrical Equipments Installation for the Inspection Method Development Based on IEC 60364)

  • 정진수;한운기;이한상
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.36-41
    • /
    • 2009
  • 본 논문에서는 건축물 전기설비의 IEC 60364를 기반으로 개발된 점검기법을 이용하여 실태 조사를 실시하였다. 점검기법 개발을 위한 분석대상은 기술기준에 준하여 시공된 국내 건축전기설비와 IEC 60364로 시공된 건축전기설비를 대상으로 차이점을 분석하였다. 측정 요소는 Loop impedance, 차단기 동작특성, 보호도체의 연속성을 측정하였다. 조사결과 국내 건축전기설비의 경우 TT시스템과 유사하지만 보호도체의 연속성에 문제가 있었다. TN-C-S로 시공된 건축전기설비의 경우 시공은 정확하게 되어 있었으나 담당자의 IEC 60364와 관련된 이해가 부족한 상태였다.

공동주택 욕실 배기팬의 플랙시블 덕트 시공상태에 따른 환기효율에 관한 연구 (A Study on the Ventilation Efficiency of Apartment Housing Bathroom Based on the Flexible Installation Method of Exhaust Fan.)

  • 이광명;함진식
    • 한국주거학회논문집
    • /
    • 제16권1호
    • /
    • pp.73-79
    • /
    • 2005
  • The ventilation efficiency of apartment housing bathroom has been measured by the flexible's diameter, length, and installation format to the exhaust In. The gas density attenuation method of Tracer Gas Method has been specifically utilized for this measurement. Full size mock-up of apartment housing bathroom, which was approximately $100 m^2$ in size, has been established for the ventilation emciency measurement. In addition, the ventilation efficiency has been studied by the possibility of air-supply In. The diameters of flexible are 100 mm, 125 mm, and 150mm. It also have the length of 1.0m, and 1.5 m. The installation formats are I shape, L shape, and S shape. As a result of this measurement, the flexible which has the highest ventilation efficiency was the one has bigger diameter, short in length, and I shape installation format.

지반조건에 따른 마이크로파일 설치방법에 관한 연구 (Installation of Micro-piles Appropriate to Soil Conditions)

  • 황태현;문경련;신용석;권오엽
    • 한국지반공학회논문집
    • /
    • 제28권4호
    • /
    • pp.55-65
    • /
    • 2012
  • 본 연구는 지반조건에 따른 효과적인 마이크로 파일의 설치방법을 제안하기 위해 실트 또는 모래지반에서 모형시험을 수행하였다. 시험결과, 관입 전단파괴가 발생한 실트지반은 압축변위에 저항하도록 마이크로 파일을 엇갈리게 설치(${\theta}$ < $0^{\circ}$)하는 것이 효과적이며, 전면 또는 국부전단파괴가 발생한 모래인 경우 횡 방향 변위에 저항하도록 마이크로 파일을 경사지게 설치(${\theta}$ > $0^{\circ}$ 또는 ${\theta}$ < $0^{\circ}$) 하는 것이 효과적인 것으로 나타났다.

해저 파이프라인 가설 분석 기술 (Advanced Offshore Pipelaying Analysis techniques Part 2 : Laybarge Methods)

  • 최한석
    • 한국해양공학회지
    • /
    • 제9권2호
    • /
    • pp.7-19
    • /
    • 1995
  • Various laybarge methods for offshore pipeline installation are introduced. Pipe stresses and strains during the installation are discussed with linear and nonlinear analysis methods. Several operational modes of offshore pipeline installation are described. Computer modelling techniques of the pipeline installation analyses are suggested.

  • PDF

보조접지그리드의 시설에 의한 대지표면전위경도의 저감 (Reduction of the the Ground Surface Potential Gradients by Installing Auxiliary Grounding Grids)

  • 이승칠;엄주홍;이복희;김효진
    • 조명전기설비학회논문지
    • /
    • 제16권2호
    • /
    • pp.121-129
    • /
    • 2002
  • 본 논문에서는 효과적인 접지그리드 설치기법에 대하여 기술하였으며, 낙뢰나 지락고장서지, 개폐서지 등으로 부터 인체의 감전보호나 컴퓨터를 비롯한 전기·전자기기의 보호를 위한 접지그리드의 시설 및 배치방법에 따른 실험적인 평가를 수행하였다. 접지그리드의 배치에 따른 대지표면전위경도의 분석과 위험전압으로 작용하는 대지 표면전위상승의 억제에 주안점을 두고 실험용 모델접지전극을 시설한 후 임 펄스전류를 인가하였다. 기존의 등간격 접지그리드의 결점을 보완하기 위해 접지그리드에 경사를 가지는 보조접지그리드를 시설하였으며, 보조접지그리드를 시설한 접지시스템에서는 인체나 전기·전자기기에 위험전압으로 작용하는 대지표면전위경도를 최대 50%이상 완화시키는 효과를 얻었다.

인스톨레이션 공간에서 나타나는 하이퍼매개적 특성 (A Study on Characteristics of Hypermediacy Revealed in Installation Space)

  • 이상준;이찬
    • 한국실내디자인학회논문집
    • /
    • 제23권5호
    • /
    • pp.41-50
    • /
    • 2014
  • In relation to spatial expression, the remediation theory of Jay David Bolter & Richard Grusin shows a sufficient possibility of providing extended idea and experience through the space of critical representation. The remediation theory discussed in the scope of new media says about the existence method and the development process of media through immersion into media and awakening, and one attribute of remediation which aims at the extension of another realistic experience and recognition through various media, contains common denominators which display diversity and complexity of installation space, and use the audience as expression elements. Therefore, this study aims to apply the remediation theory in order to interpret space using more diverse and multisensory expression methods. For achieving this purpose, this study found the connection among characteristics of hypermediacy which is an axis of installation and remediation theory, and analyzed diverse cases regarding installation space and characteristics of hypermediacy, depending on external aspects of form and expression and internal aspects of experience and cognition. The method of hypermediation expression in installation space converts the recognition about the basic custom of new experience, space and representation. This means that the logic of remediation could approach space by leading to more extended form and recognition. In conclusion, the characteristics of space and the possibility of extended expression revealed in the relationship between installation space and hypermediacy logic would provide another developmental significance for research on space design.

입도에 따른 지오그리드의 시공손상계수 산정 (Evaluation of Installation Damage Factor for Geogrid with Particle Size)

  • 임성윤;송창섭
    • 한국농공학회논문집
    • /
    • 제52권3호
    • /
    • pp.113-120
    • /
    • 2010
  • Reduction factor for installation damage required to calculate design strength of geogrid used in MSEW(mechanically stabilized earth wall) design is usually obtained in the field test simulating real construction condition. However, damages occurred in geogrid during backfill work are influenced by many factors such as polymer types, unit weight per area, backfill construction method and gradation of backfill material and field test considering these factors demand lots of time and costs. In this study, factors affecting installation damage are analyzed and empirical method to evaluate reduction factor for installation damage using maximum particle size in backfill material is suggested.

지중송전선로 병행지선 최적 설치 방안에 관한 연구 (A Study on Optimal Installation Method of Earth Continuity Conductor on Underground Power Cable Systems)

  • 정채균;강지원;윤종건;김양상
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1689-1694
    • /
    • 2009
  • In a previous paper, the characteristics of ECC (earth continuity conductor) have been analysed for reducing the level of induced sheath voltage considering the dimension and position of ECC, the spacing between ECC and three phase cables, and the use of two ECC conductors at the single point boned section of underground power cable system. From these results, the study conditions for optimal installation has been selected such as installation section, conductor size and etc. In this paper, 5 cases which are set by possible installation conditions are tested based on previous research results. Finally, the optimal installation method of ECC is selected on underground power cable systems.

실제 설치 및 유지보수 조건을 고려한 고속도로 터널조명 보수율 산정 연구 (A Study on the Calculation of Maintenance Factor(MF) of Tunnel Lighting in Expressway Considering the Actual Installation and Maintenance Conditions)

  • 이민욱;박광용;김필영;박용진;김훈
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.7-15
    • /
    • 2013
  • In lighting design, the calculation of maintenance factor is performed by calculation considering light source, characteristics of luminaire and environmental factors. The method to calculate the current maintenance factor applied to tunnel lighting design takes into consideration only pollution factors in tunnels. In addition, the calculation method should be change in response to changes of tunnel conditions and used light sources. In this study, the calculated factor of the maintenance factor in tunnel is determine by four calculation factors generally applied to the calculation of maintenance factor. This study examined the method of calculating the maintenance factor of tunnel lighting that can be applied according to the installation conditions in designing tunnel lighting by applying the actual installation data of luminaire.