• Title/Summary/Keyword: Install Criteria

Search Result 58, Processing Time 0.027 seconds

Research about Expansion Joint of Continuous Welded Rail on Reset (장대레일 신축이음매 재설정에 관한 연구)

  • Min, Jun-Ho;Lee, Chang-Hun;Ryu, Jae-Kwang;Kim, Hyo-San
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2129-2134
    • /
    • 2011
  • This research increases efficiency of track-maintenance repair and cuts maintenance cost with relocating Continuous Welded Rail how to set up install criteria by comprehension analysis through an on-the-spot survey and track measurement about installing place at expansion joint of Continuous Welded Rail. This scope of this research is 427 places installed at Line No.1~4, Seoulmetro. We take a field study and select two spots. So we survey wheel-load, cross-load and railbed cross-resistance and suggest install criteria of expansion joint of Continuous Welded Rail through investigation and analysis of track facilities about neighboring section of expansion joint.

  • PDF

Establishing the Structural Criteria to install Scaffolding-Use Brackets (비계지지브라켓 유형별 구조기준 설정에 관한 실험적 연구)

  • Son, Ki-Sang;Kal, Won-Mo
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.87-96
    • /
    • 1995
  • It is only three(3) years since we applied brackets for scaffolding in the construction area. Unfortunately, there is no structural criteria on how to install those in the site so far, despite the fact that those brackets have been applied into the site by the firms already. It is shown that resistant capacity of each bracket type has been investigated, analyzed from this experimental study. Accident-concerning data on construction site analyzed by the Ministry of Labor, show temporary structure involves 18.6% of the total industrial accident, which the accidents from scafold-supporting brackets have rate of 42.5% of the ones occurred from the temporary structures. There are two main aspects to be observed : one is how much resistant capacity the brackets have themselves, the other is how exactly to install those without eccentricity. But practically, nobody does check of this bolt-installing conditions in the site and no check of tightening level of nut because there is no available tool to check torque amount for this kind of nut. We just have to rely on scaffolders experience of this tightening. This experiment involves just this variable of tightness at site. Eventually this insufficient tightness causes to collapse those scaffolding structures. The bracket might have less the one than its original capacity due to this insufficient tightness. Three(3) times of PIVOT tests show that fractured condition of two(2) row brackets has occurred mostly at lower bolt due to shear force. Therefore, tightness of bracket-installing bolt, tensile strength of the bolt, shear strength of the bolt, loading condition with equal two point or inequal two point loads, are mainly investigated as variables in this study.

  • PDF

Design criteria of wind barriers for traffic -Part 2: decision making process

  • Kim, Dong Hyawn;Kwon, Soon-Duck;Lee, Il Keun;Jo, Byung Wan
    • Wind and Structures
    • /
    • v.14 no.1
    • /
    • pp.71-80
    • /
    • 2011
  • This study presents a decision making process for installation of wind barrier which is used to reduce the wind speed applied to running vehicles on expressway. To determine whether it is needed to install wind barrier or not, cost and benefit from wind barrier are calculated during lifetime. In obtaining car accidental risk, probabilistic distribution of wind speed, daily traffic volume, mixture ratio in the volume, and duration time for wind speed range are considered. It is recommended to install wind barrier if benefit from the barrier installation exceed construction cost. In the numerical examples, case studies were shown for risk and benefit calculation and main risky regions on Korean highway were all evaluated to identify the number of installation sites.

Development of Determination Criteria Installing Crash Cushion on Freeway Off-Ramp (고속도로 진출램프 부근의 충격흡수시설 설치여부 판단기준 개발에 관한 연구)

  • 하태준;박제진;오재철
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.7
    • /
    • pp.107-116
    • /
    • 2002
  • Crash Cushion is a kind of safety facilities on roadside which acts the role of absorbing impact energy when vehicles are driven out of normal route such as Gore area of freeway off ramp. Criteria for severity index considering accident occurrence possibility are needed to have strong effect on installing the facilities. However, present criteria for establishing crash cushion design do not include such processes. Therefore, the paper presents two kinds of study to develop criteria for severity index. First of all, development of accident forecasting model on freeway off ramp is presented. The module is a relationship between accidents and road environment by negative binomial distribution (NB) which is called to reflect very well quality of accidents at Gore of crash cushion installed freeway Secondly, freeway exiting behavior model is developed because the human factor is the most important one. However, many literatures have shown between road environment and accidents which are more quantitative than human factor. The study supposed advanced process steps on actual freeway and analysed correlation between variables and accidents. The criteria for severity index is presented to determine whether to install or not by benefit cost analysis for each module. The standard for severity index will help to determine whether to install the crash cushion or not and to estimate severity for freeway and off ramp.

The Development of Beamline Hutch Structures at PAL-XFEL (PAL-XFEL 빔라인 허치 구조물 개발)

  • Kim, Seungnam;Kim, Myeongjin;Kim, Seonghan;Kim, Yeongchan;Shin, Hocheol;Kim, Jihwa;Kim, Kyeongsuk;Kim, Kwangwoo;Eom, Intae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.567-577
    • /
    • 2016
  • The hutches which are installed in the beamline are largely classified into two, i.e XPP (X-ray pump probe) and CXI (Coherent X-ray image). Laser room is installed on the hutch and provides laser to XPP and CXI simultaneously. And two hutches have heavy crane to install some optics equipments. Safety and reliability of hutch structures should be taken into account for the precise operating of the laser facilities, so vibration analysis is essential to do this. The main purpose of vibration analysis is to install hutch structures with large stiffness. We have changed materials specification several times to install hutch structures having strong stiffness. Now hutch structures were installed and checked vibration status at laser room and XPP hutch. The results of laser table and robot arm satisfy vibration criteria. This paper explains about the design and vibration analysis of hutch structures.

Analysis of Security Requirements for Secure Update of IVI(In-Vehicle-Infotainment) Using Threat Modeling and Common Criteria (위협모델링과 공통평가기준을 활용한 인포테인먼트의 안전한 업데이트 보안요구사항 분석)

  • Kang, Soo-young;Kim, Seung-joo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.3
    • /
    • pp.613-628
    • /
    • 2019
  • In-Vehicle Infotainment provides navigation and various functions through the installation of the application. And infotainment is very important to control the entire vehicle by sending commands to the ECU. Infotainment supports a variety of wireless communication protocols to install and update applications. So Infotainment is becoming an attack surface through wireless communcation protocol for hacker's access. If malicious software is installed in infotainment, it can gain control of the vehicle and send a malicious purpose command to the ECU, affecting the life of the driver. Therefore, measures are needed to verify the security and reliability of infotainment software updates, and security requirements must be derived and verified. It must be developed in accordance with SDL to provide security and reliability, and systematic security requirements must be derived by applying threat modeling. Therefore, this paper conducts threat modeling to derive infotainment update security requirements. Also, the security requirements are mapped to the Common Criteria to provide criteria for updating infotainment software.

The Optimized Standards and Criteria for Installing Switches on Distribution Feeder (국내 배편계통의 최적 개폐기 설치 기준)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.238-246
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in stun dards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches Is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

Improvement of Vehicle Classification Method using Vehicle Height Measurement (차량높이 계측을 통한 차종분류 향상 방안 연구)

  • Oh, Ju-Sam;Jang, Kyung-Chan;Kim, Min-Sung
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.47-51
    • /
    • 2010
  • A vehicle classification data is essential for traffic road planning and pavement. In this study, the vehicle height, vehicle criteria for classification applied to measure the height of the car driving has devised a way to install equipment. It is capable of measuring the vehicle height was confirmed to field experiments, the measurement system is obtained to the vehicle length and height data. In this experiment, results showed the accuracy of 88.6% compared to classification data using the discriminant function obtained from video replaying. The height of vehicle applying the classification criteria can be utilized to determine the vehicle class.

The optimized standards and criteria for installing switches on distribution feeder (국내 배전계통의 최적 개폐기 설치 기준(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.70-73
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in standards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

  • PDF

Manufacture of Versatile Phantom for the Daily Quality Assurance of Radiation Therapy Equipments (방사선치료 장비들의 매일 정도관리를 위한 다용도 모형의 제작)

  • Cha, Dong-Soo;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.59-64
    • /
    • 2010
  • We examined the accuracy and efficiency of phantom by applying the designed phantom in order to check daily quality assurance easily by objective criteria and to confirm daily quality assurance of linear accelerator, simulator, and CT-simulator. The results of 10 weeks of linear accelerator output dose using American Association of Physicists in Medicine(AAPM) daily quality assurance guide were measured within ${\pm}1%$ of error. Mechanical check of laser alignment, optical distance indicator(ODI), CT scanner laser and alignment of gantry lasers with the center of imaging plane were measured within ${\pm}1mm$. Daily average working time for daily quality assurance of radiation therapy equipments was 38 minutes. The designed phantom was easy to install and daily quality assurance was possible with only one installation. The aspects reproducibility and efficiency as well as accuracy of quality assurance were excellent.

  • PDF