• 제목/요약/키워드: Inside diameter

Search Result 738, Processing Time 0.027 seconds

A Study on Extru-Bending Process Extrusion Bending Machine (열간금속 압출굽힘기를 이용한 금속곡관의 압출굽힘가공에 관한 연구)

  • 박대윤;진인태
    • Transactions of Materials Processing
    • /
    • v.11 no.3
    • /
    • pp.262-268
    • /
    • 2002
  • The bending process for the rectangular and circular curled tube can be developed by the hot metal extrusion machine with the multiple punches moving in the different velocity. The bending phenomenon has been known to be occurred by the different of velocity at the die exit. The difference of velocity at the die exit section can be obtained by the different velocity of billets through the multi-hole container and by the cohesion of billet Inside the porthole die chamber. The bending phenomenon can be controlled by the two variables, the one of them is the difference of velocity at the die edit section by the different velocity of billets through the multi-hole container The other is the difference by the different hole diameter The results of the experiment show that the rectangular curved tube can be formed by the extrusion process, that the curvature of the curved product can be controlled by the velocity of punch and the diameter of container hole, that the defects such as the distortion of section and the thickness change of the wall of tube and the folding and wrinkling of thin tube did not happen after the extra-bending processing by the extrusion bending machine.

Thermal Performance Analysis of Glass Evacuated Solar Collector with a Finned Tube (내관에 휜을 부착한 진공관형 집열기의 열성능 해석)

  • Kim, Yong;Seo, Tae-Beom;Kang, Yong-Hyuk
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • The thermal performance of glass evacuated tube solar collectors with finned tubes is numerically modelled with code and investigated to see the effect of toe inner tube diameter and incidence angle. The solar collector consists of a two-layered glass tube and an inner tube. Finned tubes are used as the inner tube of the collector in order to improve the performance of the solar collector. Two strip-type fins are attached on the opposite sides of the inner tube surface. The fin is wide enough to be tightly fatted inside the glass tube. The results show that if the incidence angle is small, the effect of the tube diameters is not significant on the thermal performance and the outlet air temperature. If the incidence angle is large, however, the outlet air temperature and the performance increases as the inner tube diameter increases.

Heat Transfer in a Two Wall Divergent Rectangular Channel with V-Shaped Ribs on One Wall (한 벽면에 V형 리브가 있는 2면 확대 사각채널의 열전달)

  • Lee, Myung-Sung;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.19 no.5
    • /
    • pp.32-37
    • /
    • 2015
  • The present study is to investigates the convective heat transfer characteristics and pressure drop inside the rib-roughened cooling passage of gas turbine blades. The divergent rectangular channel is fabricated with V-shaped ribs on one wall only and the inlet hydraulic diameter to outlet hydraulic diameter ratio($D_{ho}/D_{hi}$) of 1.49 is used. The current investigation has covered a Reynolds number (Re) range of 22,000~75,000, relative roughness height ($e/D_h$) of 0.1~0.2, and rib angle of attack (a) of $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ for a fixed relative pitch of 10. Results show that the Nusselt numbers are the greatest in the $60^{\circ}$-angled ribs; however, the total friction factors are the highest in the $30^{\circ}$-angled ribs.

A Study on the Design Optimization of Corner Pprotection for LNG Storage Tank (LNG저장탱크 코너프로텍션의 설계 최적화에 관한 연구)

  • Kim, Hyung-Sik;Hong, Seong-Ho;Seo, Heung-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.9
    • /
    • pp.1384-1390
    • /
    • 2004
  • The full containment Liquefied Natural Gas(LNG) storage tank is based on a double liquid container concept : two separate containers, one within the other, are capable of containing the LNG. The outer concrete tank provides comer protection(secondary containment) to withstand and safely contain any spill from the inner tank. The comer protection is installed on inside corner surface of outer concrete tank. Because of high and complex stresses, corner protection is designed by ASME section ⅧI Div. 2, Appendix 4 on behalf of API 620 which is main design code for LNG tank. Design guidelines to determine design factors such as liner thickness and knuckle radius are not well understood because Appendix 4 is the design method not based on equation but FEM. Recently, the volume of LNG tank shows a tendency to increase. So it is necessary to set up the design guidelines to cope with change of LNG tank capacity and height/diameter ratio. In this paper, optimum design of corner protection was performed and the design guidelines were suggested by the results of FEM for LNG tanks which have different capacities and height/diameter ratio.

The Characteristics of the Composite Ground with Sand Compaction Pile(SCP) using Large Soil Box (대형토조시험을 이용한 모래다짐말뚝이 적용된 복합지반의 침하 및 하중전이특성)

  • Kim, Oo-Seok;Park, Eon-Sang;Kim, Jae-Kwon;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.974-981
    • /
    • 2005
  • Because general laboratory tests for sand compaction pile method including unit-cell test device have fixed outside diameter, as area replacement ratio increase, diameter of sand pile increase. These condition can bring about overestimation of stiffness of composite ground. In addition, existing large soil box which consist of bellows type loading plate can occur serious mistake in checking the amount of drained water because there are additional drainage along the inside wall in device. Overcoming these shortcoming, this paper developed modified large scale soil box consist of piston type load plate. In this study, using this device, series of modified large scale soil box tests were performed, and investigated the settlement and stress transportation characteristics with area replacement ratio in sand compaction pile method.

  • PDF

Effects of Flow Diretion and Annular Gap Size on the Flow Pattern and Void Distribution in a Vertical Two-Phase Flow(I) - In Case of Upward Flow - (수직이상유에서 유동방향과 동심원관 간극이 유동양식과 보이드분포에 미치는 영향 (I))

  • 손병진;김인석;김문철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.5
    • /
    • pp.856-866
    • /
    • 1987
  • In the present paper a statistical method using probability density function has been applied to investigate experimentally the flow patterns and fluctuations of time-averaged local void fraction in air-water two-phase mixtures which flow vertically upwards in concentric annuli. This study was carried out using three vertical concentric annuli. The annular test section consists of a lucite outer tube whose inside diameter is 38mm and a stainless steel inner rod. The rod diameter is either 12mm, 16mm or 20mm. The two-phase flow patterns observed in the experiment were bubbly, slug, annular and each transition patterns. It was first demonstrated that the variance, coefficients of skewness and kurtosis calculated from probability density function on time-averaged local void fraction can be used to identify the flow patterns in the annular passage, and the fluctuation of time-averaged local void fraction varies with the radial position in annular gap and the flow pattern.

Noise Reduction of a Underexpanded Supersonic Jet via Steady Blowing with Microjets (소형제트를 이용한 과소팽창 음속 제트에서의 소음저감)

  • Kim Jin-Hwa;Kim Jung Hoon;Yoo Jung Yul
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.747-750
    • /
    • 2002
  • An attempt to reduce supersonic Jet noise is carried out by using two steady microjets in a round jet. The jet is issued from a round sonic nozzle with an exit diameter of 10mm. Two micro-nozzles with an inside diameter of 1mm each are installed on the exit plane with an off-axis angle of $45^{\circ}$. Far-field noise was measured at a location 40 diameters off the jet axis. The angles between a microphone and the jet axis are $45^{\circ}\;and\;90^{\circ}$. For an injection rate less than $1{\%}$ of the main jet, screech tones were completely suppressed by the microjets. The reduction in the ovelall sound pressure levels were $2.4\;and\;2.7\;dB\;for\;90^{\circ}\;and\;45^{\circ}$ directions, respectively. The enhancement of mixing/spreading of the jet by the microjet was negligible. The reduction of noise is probably due to distorted shock cell structures and/or broken large scale vortical structures by the microjets.

  • PDF

Comparison of the Thermal Performance with Stationary and Tracking Evacuated CPC Collectors (고정형과 추적형 Evacuated CPC 집열기의 열성능 비교)

  • Yun, Seong-Eun;Kim, Yong;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.19-25
    • /
    • 2004
  • A numerical study is performed to investigate the effect of sun tracking on the thermal performance of the evacuated compound parabolic concentrator (CPC) collectors. The evacuated CPC collectors consist of a two-layered glass tube, a copper tube and a reflector. The collector has a copper tube as an absorber and a reflector inside a glass tube. The water is used as a working fluid. The length and the diameter of the glass tube are 1,700mm and 70mm, respectively. The length and the diameter of the copper tube are 1,700mm and 25.4mm, respectively. Ray tracing analysis is carried out in order to compare absorbed heat fluxes on the absorber surface of the stationary and tracking collectors. The collected energy is calculated and compared with that on a fixed surface tilted at $35^{\circ}$ on the ground and facing south. The results indicate that the collected solar energy of the sun tracking system is significantly larger than that of a stationary collector. The sun tracking evacuated CPC collectors show a better performance with an increase in the thermal efficiency of up to 14% compared with an identical stationary collector.

Influence of Working Fluids to Heat Transfer Characteristics of Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery

  • Lee, Wook-Hyun;Im, Yong-Bin;Kim, Ju-Won;Kim, Jeung-Hoon;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.27-35
    • /
    • 2001
  • Heat transfer characteristics of a heat exchanged for low temperature waste heat recovery using oscillating capillary tube heat pipe (OCHP) were evaluated against the charging ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working a 2.6mm in outside diameter, 1.44mm in inside diameter with 101m length and 140 turns. Charging ratio of working fluid was 40% and 50%. water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and 9~27 $4kg/m^2s$, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-142b and R-290 and it was proportional to Figure of Merit for thermosyphon. As a result, it was thought that R-22 was the most reasonable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

Anti-Fouling System for Oscillating Water Column in Buoy (진동 수주형 브이의 Anti Fouling system)

  • Oh, Jin-Seok;Jo, Kwan-Jun
    • Journal of Navigation and Port Research
    • /
    • v.34 no.6
    • /
    • pp.441-445
    • /
    • 2010
  • The ouput power of wave energy system in buoy is determined according to the inner diameter of oscillating water column and flow resistance. The increase of adhered shellfish inside the water column leads to decrease the inner diameter of wave energy converter. Influx loss of seawater reduces the efficiency of output power in the wave generation system. In this paper, the test result of AFS characteristic is described for preventing the deposition with shellfish and etc. The current of anode is controlled by buck converter, and the control algorithm developed for AFS in buoy. The experimental results is shown excellent preventing capapbility of AFS in buoy.