Shape Oscillation and Detachment of Droplet on Vibrating Flat Surface (진동하는 평판 위의 액적의 형상 진동 및 제거 조건에 대한 연구)

  • Shin, Young-Sub;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.337-346
    • /
    • 2014
  • This study aimed to understand the mode characteristics of a droplet subject to periodic forced vibration and the detachment of a droplet placed on a plate surface. An surface was coated with Teflon to clearly observe the behavior of a droplet. The contact angle between the droplet and surface and the hysteresis were found to be approximately $115^{\circ}C$ and within $25^{\circ}C$, respectively. The coating process was performed in a clean room that had an environment with a low level of contaminants and impurities such as air dust, detergents, and particles. To predict the resonance frequency of a droplet, theoretical and experimental approaches were applied. Two high-speed cameras were configured to acquire side and top views and thus capture different characteristics of a droplet: the mode shape, the detachment, the separated secondary droplet, and the waggling motion. A comparison of the theoretical and experimental results shows no more than 18 discrepancies when predicting the resonance frequency. These differences seem to be caused by contact line friction, nonlinear wall adhesion, and the uncertainty of the experiment. For lower energy inputs, the contact line of the droplet was pinned and the oscillation pattern was axisymmetric. However, the contact line of the droplet was de-pinned as the oscillation became more vigorous with increased energy input. The size of each lobe at the resonance frequency is somewhat larger than that at the neighboring frequency. A droplet in mode 2, one of the primary mode frequencies, exhibits vertical periodic movement as well as detachment and secondary ejection from the main droplet.

Removal of SF6 over Silicon Carbide with Aluminium Oxide by Microwave Irradiation (마이크로웨이브 조사에 따른 산화알루미늄이 함유된 실리콘카바이드의 SF6 제거)

  • Choi, Sung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.4
    • /
    • pp.240-246
    • /
    • 2013
  • $SF_6$ is the most important greenhouse gas with the highest GWP (global warming potential). The $SF_6$ decomposition study was performed with silicon carbide with aluminium oxide by microwave irradiation. DRE (Decomposition and Removal Efficiencie) of $SF_6$ were evaluated by GC-TCD unit using 3,000 ppm $SF_6$ gas. DRE of $SF_6$ was increased by $Al_2O_3$ contents to 10~30 wt%, otherwise $Al_2O_3$ content of 40~50 wt% was decreased. DRE of $SF_6$ up to 99.99% have been achieved in SiC-$Al_2O_3$ (20 wt%) and SiC-$Al_2O_3$ (30 wt%) above $900^{\circ}C$. Also, the DRE of SiC-$Al_2O_3$ (30 wt%) at $700^{\circ}C$ showed 96.72%. In addition to consideration microwave input energy and $Al_2O_3$ content, SiC-$Al_2O_3$ (30 wt%) can be suggested the best material to control $SF_6$. The results of this study suggest it is important to control content of $Al_2O_3$ in SiC for decomposition of $SF_6$ with microwave energy.

A Study about Water Footprint Evaluation of Industrial Sectors (국내 산업들의 물 발자국 산정에 관한 연구)

  • Kim, Junbeum;Kang, Hun;Park, Kihak
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.400-406
    • /
    • 2013
  • Water footprint means the direct and indirect water resource amount used for the life cycle of different goods, services and industries. In this study, the direct and indirect water resource consumption in industrial sectors were calculated by using water footprint evaluation method. As a result, agriculture and marine product industry takes part of 93% of whole water resource amount, showing the greatest amount of basic unit of water coefficient (637 $m^3/won$) following by petroleum and cool products industry of about 13 $m^3/won$. In the agriculture and marine product industry, the direct water consumption was only 25 billion $m^3$ compared to the indirect water, which is 130 billion $m^3$. The next highest industry was chemical product industry, which consists of 2 billion $m^3$ of the direct water and 4.5 billion $m^3$ of the indirect water consumption. In case of industries which have high direct water, it would be more effective to reduce amount of water related to the industry than to reduce water in actual process. This water footprint of each industry and evaluation method will be useful tool and method for development of national water management policy and regulation.

Emergy Evaluation of the Korean Economy and Environment: Implications for the Valuation of Marine Ecosystem Services (한국 경제와 자연환경의 에머지 평가: 해양생태계서비스 가치평가 시사점)

  • Kang, Daeseok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.2
    • /
    • pp.102-115
    • /
    • 2015
  • Several emergy researches have been carried out to estimate the value of marine ecosystem services in Korea over the last decade. Their results cannot be compared mainly due to inconsistency in emergy-money ratios used to convert emergy unit into monetary unit. This study aimed at providing a standardized format for the emergy evaluation of the Korean economy and environment for different emergy evaluations to be compatible. Even though the area of the continental shelf increased in this study compared to those of previous studies, areaweighted average tidal range for the entire continental shelf of Korea resulted in smaller tidal range, decreasing the final emergy input from tide. However, emergy inputs from nonrenewable resources and purchased goods and services increased with new categorization and use of more detailed data, combined with updated unit emergy values. This led to higher emergy-money ratio for the Korean economy, indicating that previous emergy valuations might have overestimated the contributions of marine ecosystem to the real wealth of the Korean society. The base year for gross domestic product used in the emergy evaluation needs to be clearly indicated due to its impact on the calculation of the emergy-money ratio. A standardized emergy table for the Korean economy will contribute to ensuring consistency among future emergy researches on the valuation of marine ecosystem services.

Effective Costal Environmental Management by Conjugation of Modeling of Bio-Purification and Total Allowable Pollutant Loads in Masan Bay (생물정화기작과 총허용오염부하량을 연계한 마산만의 효율적 해양환경 개선방안)

  • Eom, Ki-Hyuk;Kim, Gui-Young;Lee, Won-Chan;Lee, Dae-In
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.1
    • /
    • pp.38-46
    • /
    • 2012
  • This study carried out current status, characteristics, and problems of coastal environment management on semi-enclosed Masan Bay in Korea and suggests cost-effective and eco-friendly water quality management policy. The pollutants from terrestrial sources into the Bay have apparently environmental pollution problems, such as eutrophication, red tide, and hypoxia. The carrying capacity of the Bay is estimated by hydrodynamic model and ecosystem model, material circulation including bivalve in ecosystem is analyzed by the growth model of bivalve. The resulting reduction in the input load was found to be 50~90%, which is unrealistic. When the efficiency of water quality improvement through bivalve farming was assessed based on the autochthonous COD, 30.7% of the total COD was allochthonous COD and 69.3% was autochthonous COD. The overall autochthonous COD reduction rate by bivalve aquaculture farm was found to be about 6.7%. This study indicate that bivalve farming is about 31% less expensive than advanced treatment facilities that remove both nitrogen and phosphorous.

Estimation of spatial evapotranspiration using Terra MODIS satellite image and SEBAL model in mixed forest and rice paddy area (SEBAL 모형과 Terra MODIS 영상을 이용한 혼효림, 논 지역에서의 공간증발산량 산정 연구)

  • Lee, Yong Gwan;Jung, Chung Gil;Ahn, So Ra;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.3
    • /
    • pp.227-239
    • /
    • 2016
  • This study is to estimate Surface Energy Balance Algorithm for Land (SEBAL) daily spatial evapotranspiration (ET) comparing with eddy covariance flux tower ET in Seolmacheon mixed forest (SMK) and Cheongmicheon rice paddy (CFK). The SEBAL input data of Albedo, Land Surface Temperature (LST), Normalized Difference Vegetation Index (NDVI) from Terra MODIS products and the meteorological data of wind speed, and solar radiation were prepared for 2 years (2012-2013). For the annual average flux tower ET of 302.8 mm in SMK and 482.0 mm in CFK, the SEBAL ETs were 183.3 mm and 371.5 mm respectively. The determination coefficients ($R^2$) of SEBAL ET versus flux tower ET for total periods were 0.54 in SMK and 0.79 in CFK respectively. The main reason of SEBAL ET underestimation for both sites was from the determination of hot pixel and cold pixel of the day and affected to the overestimation of sensible heat flux.

Biogas production using organic waste (유기성 폐기물을 이용한 바이오가스 생산)

  • Yoo, Eunsil;Hong, Soonhyouk;Kim, Daeyoung;Jun, Haks
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.110.2-110.2
    • /
    • 2011
  • 바이오가스 생산은 현재 정부에서 추진하고 있는 저탄소 녹색성장으로 인해 더욱 그 가치의 중요성이 부각되고 있다. 스웨덴 Scandinavian Biogas Fuel AB(SBF) 사의 바이오 가스 생산 기술을 이용함으로 소화효율을 개선하고 바이오가스 발생량을 극대화하였다. 전국 403개 공공하수처리시설 중 소화조가 설치된 처리시설은 65 개소이며 이중 57 개소에서 총 64개 소화조를 운영 중이다. 하지만 국내 소화조의 효율은 유입수질 저하, 운영, 관리 미숙으로 인해 전진국의 1/4 수준으로 에너지 이용률이 미미한 편이다. 환경부는 2010년부터 에너지 이용, 생산사용 확대, 추진을 위해 하수처리시설별 이용 가능한 에너지 잠재력의 종류, 양, 지역 내 수요자, 공급자 의 현황 규모 등을 정리해 2012년부터 에너지 이용사업 확대를 추진한다. SBF의 기술을 바탕으로 하수처리시설에서 들어오는 하루 슬러지 $1370m^3$와 음식물쓰레기 180t을 함께 처리하며 바이오가스 생산량을 더욱 늘렸다. 각 $7,000m^3$의 달걀모양(egg shape) 소화조 2개를 운영하며 생 슬러지와 음식물 쓰레기 처리 후 바로 소화조로 투입, 혐기 소화하는 방식이며 슬러지 최종처분방법은 탈수 후 소각된다. 반입되는 생 슬러지의 평균 TS 1.7%, VS 63% 이며 농축 후에는 평균 TS 9%, VS 75% 이다. 또 소화조로 들어가는 음식물 쓰레기는 평균 TS 8%, VS 85% 이며 소화 후 평균 TS 3.6% VS 59% 이다. 그리고 소화조의 pH는 7.3~7.8,유기산의 농도는 150mg/L~350mg/L, 가스발생량은 하루 평균 $26,500Nm^3$이며 소화효율은 평균 67%이다. 혐기성소화는 산소가 없는 무 산소 상태 에서 분해 가능한 유기물을 분해시켜 메탄으로 전환시키고 우리는 현재 이 가스를 소화조 가온에 사용하고, 판매하고 있다. 소화효율을 높이기 위하여 가온과 교반이 행해지는데 가온방식은 직접가온방식(증기주입식)과 간접가온방식(열교환방식)이 있다. 그중 우리는 간접가온방식을 채택하여 소화효율을 높였고 일반중온 혐기소화온도보다 약간 높은 $38^{\circ}C$로 운전한다. 그리고 일반적으로 알려진 교반방식인 가스교반, 기계교반, 이 둘은 병행한 교반이 아닌 독자적인 방법을 이용, 소화조 내의 슬러지가 정체되어 교반되지 않는 부분을 최소화 하였다. 이때 미생물이 투입되기 힘든 소화조 아래 쪽 으로도 고루분포 되어 슬러지를 이용 하게 되고 소화조 상하부의 온도차가 $1^{\circ}C$ 이하로 거의 완벽한 교반상태를 보여 줌 으로써 소화효율을 최대한으로 한다. 더욱이 소화일수 부족으로 인한 전반적 소화효율 저하가 발생하지 않도록 input과 output 조절을 통한 적정소화일수 20~25일을 최대한 맞추어 운전하여 소화조 설계용량의 평균 90%를 활용하고 있다.

  • PDF

A Study of Efficient Removal of 2-Methylisoborneol and Geosmin by Pulsed Ultraviolet and Ultrasound (효율적인 2-Methylisoborneol, Geosmin의 제거를 위한 Pulsed UV 공정과 Ultrasound 공정의 비교 연구)

  • Han, Jonghun;Hur, Jiyong;Kim, Kangwook;Lee, Junyoung;Park, Wonseok;Lee, Jongyeol;Her, Namguk
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • The degradation of off-flavors which is 2-Methylisoborneol (2-MIB) and geosmin by means of ultrasound (US) and pulsed ultraviolet (PUV) irradiation and its combination with catalyst (wire mesh, wire mesh coated TiO2, and TiO2) and additive (H2O2) were investigated via water system. A combination treatment of TiO2 and H2O2 heterogeneity with US (24 kHz) and PUV (6000 W) has shown improved results in destroying 2-MIB and geosmin, which may be attributed to chain reactions by the enhanced formation of hydroxyl radicals (·OH) through H2O2 dissociation and reactive oxide ions of TiO2 addition. Rapid degradation of off-flavors occurred within 2 min under PUV process with H2O2 100 mg/L (81.5% for 2- MIB; 79.3% for geosmin) and TiO2 100 mg/L (83.7% for 2-MIB; 79.8% for geosmin), while compared with H2O2 100 mg/L (58.4% for 2-MIB; 58.0% for geosmin) and TiO2 100 mg/L (59.2% for 2-MIB; 38.5% for geosmin) within 5 min under US process. Surprisingly, the emphasis was given on the comparison with the same injected energies between PUV and US on degradation efficiency. Based on the injected energy comparison, the US provided better degradation performance under equal input power of 200 kJ with H2O2 100 mg/L, while compared with H2O2 100 mg/L under PUV process. Our findings suggest that US can be more effective compared to PUV for the degradation of off-flavors in aspect of energy consumptions.

Heating and cooling properties in cultivation room and cultural characteristics of oyster mushroom according to type of air exchange (외부공기 유입방식에 따른 느타리버섯 생육실의 온도변화 및 자실체의 생육특성)

  • Jang, Myoung-Jun;Lee, Yun-Hae;Ju, Young-Cheol
    • Journal of Mushroom
    • /
    • v.11 no.4
    • /
    • pp.214-218
    • /
    • 2013
  • This study was carried out to find out suitable input method for air exchange about bottle cultivation of oyster mushroom. There was no difference of average temperature in cultivation room, but T1(direct introduction of outside air) was higher than T2(heat exchanger) and T3(air buffer) in the standard deviation. The ratio of cooling operating was the highest in August and in the descending order, T1 54%, T3 43%, T2 33%. At ratio of energy reduction, T2 and T3 were higher than T1. The operating ratio of heater was highest in January and in the descending order, T1 53%, T3 37%, T2 30%. At ratio of energy reduction(%), T2 and T3 were higher than T1 similar to result of cooling operating. Therefore there were largest in August about Cooling Degree-Hour and in January about Heating Degree-Hour. And fruitbody yields quality was excellent in T2 and T3 than T1. The suitable effective type of air exchange in oyster mushroom cultivation are heat exchange and air buffer system.

Prediction of Brittle Failure within Mesozoic Granite of the Daejeon Region (대전지역 중생대 화강암 암반 내 취성파괴 예측연구)

  • Jang, Hyun-Sic;Choe, Mi-Mi;Bae, Dae-Seok;Kim, Geon-Young;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.357-368
    • /
    • 2015
  • Brittle failure of Mesozoic granite in the Daejeon region is predicted using empirical analysis and numerical modeling techniques. The input parameters selected for these techniques were based on the results of laboratory tests, including damage-controlled tests. Rock masses that were considered to be strong during laboratory testing were assigned to "group A" and those considered to be extremely strong were assigned to "group B". The properties of each group were then used in the analyses. In-situ stress measurements, or the ratio of horizontal to vertical stress (k), were also necessary for the analyses, but no such measurements have been made in the study area. Therefore, k values of 1, 2, and 3 were assumed. In the case of k=1, empirical analysis and numerical modeling show no indication of brittle failure from the surface to1000 m depth. When k=2, brittle failure of the rock mass occurs at depths below 800 m. For k=3, brittle failure occurs at depths below 600 m. Although both the Cohesion Weakening Friction Strengthening (CWFS) and Mohr-Coulomb models were used to predict brittle failure, only the CWFS model performed well in simulating the range and depth of the brittle failure zone.