• Title/Summary/Keyword: Inner Case

Search Result 1,044, Processing Time 0.025 seconds

Residue Levels of Chlorantraniliprole and Ethaboxam in Different Parts of a Head-type Korean Cabbage and Reduction of Residues in Outer Leaves by Water Washing and Heat-treatment (결구 배추의 부위별 Chlorantraniliprole 및 Ethaboxam의 잔류수준과 배추 겉잎의 수세 및 열처리에 의한 잔류량 감소)

  • Kim, Jun-Yeong;Lee, Mi-Gyung
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.330-335
    • /
    • 2014
  • This study was conducted to investigate residue levels of chlorantraniliprole and ethaboxam in inner part and outer leaves of a head-type Korean cabbage. Further, reduction of residues was measured after water washing, blanching and heat-cooking of the outer leaves. For chlorantraniliprole, residues in inner part and outer leaves were <0.01 mg/kg and 0.0757 mg/kg, respectively, in case of three-time spraying 30 days before harvest and <0.01 mg/kg and 1.19 mg/kg, respectively, in case of four-time spraying 10 days before harvest; for ethaboxam, <0.05 mg/kg and 0.216 mg/kg, respectively and <0.05 mg/kg and 1.18 mg/kg, respectively. Chlorantraniliprole and ethaboxam were not detected in inner part of the head-type Korean cabbage. Residue levels in outer leaves were very high as 10-100 fold as those in inner part of the cabbage. Therefore, there is no concern for safety of pesticide residues on kimchi prepared with the inner part of a head-type Korean cabbage. In addition, it needs to be noted that outer leaves should be carefully removed at harvest of the cabbage. Outer leaves water washed and blanched are called as Woogeogi, which is consumed after heat-cooking. In Woogeogi, residue concentrations of two compounds reduced to less than 10%, and further less than 5% by heat-cooking. This indicates that considerable amount of the test pesticide residues in outer leaves of a head-type Korean cabbage removed through water washing, blanching and heat-cooking.

Compare to Evaluate the Imaging dose of MVCT and CBCT (Tomotherapy MVCT와 Linac CBCT의 Imaging dose 비교평가)

  • Yoon, Bo Reum;Hong, Mi Lan;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • Purpose : In case of the intensity modulated radiation therapy (IMRT) using Tomotherapy and linear accelerator (Linac), it was to compare and to evaluate the imaging dose of MVCT and CBCT that were performed daily for the correct set up of the patient. Materials and Methods : The human body model Phantom (Anderson rando Phantom, USA) was divided into the three parts as Head, Thorax, pelvis, and after GafChromic EBT3 film cut to the size of $0.5{\times}0.5cm2$.in the center of the recording area were situated on the ant, post, left, and right surface of the phantom and 2cm in depth from the ant, post, left, right, and center surface of the phantom, the surface dose and inner dose were measured repeatedly three times, respectively, using the tomotherapy (Hi Art) and the OBI of NovalisTx. The measured film calculated the output value by RIP version6.0 and then the average value of the dose was calculated by the one-way analysis of variance. Results : Using the human body model phantom, the results of MVCT and CBCT performance were that measurements of MVCT inner dose were showed $15.43cGy{\pm}6.05$ in the head, $16.62cGy{\pm}3.08$ in the thorax, $16.81cGy{\pm}5.24$ in the pelvis, and measurements of CBCT inner dose were showed $13.28{\pm}3.68$ in the head, from $13.66{\pm}4.04$ in the thorax, $15.52{\pm}3.52$ in the pelvis. The measurements of surface dose were showed in case of MVCT performance, $11.64{\pm}4.05$ in the head, $12.16{\pm}4.38$ in the thorax, $12.05{\pm}2.71$ in the pelvis, and in case of CBCT performance, $14.59{\pm}3.51$ in the head, $15.82{\pm}2.89$ in the thorax, $17.48{\pm}2.80$ in the pelvis, respectively. Conclusion : In case of Inner dose, the MVCT using MV energy showed higher than the CBCT using kV energy at 1.16 times in the head, at 1.22 times in the thorax, at 1.08 times in the pelvis, and in case of surface dose, the CBCT was higher than MVCT, at 1.25 times in the head, at 1.30 times in the thorax, at 1.45 times in the pelvis. Imaging dose was a small amount compared to the therapeutic dose but it was thought to affect partially to normal tissue because it was done in daily schedule. However, IMRT treatment was necessarily parallel with the IGRT treatment through the image-guide to minimize errors between planned and actual treatment. Thus, to minimize imaging dose that the patients receive, when planning the treatment, it should be set up a treatment plan considering imaging dose, or it must be performed by minimizing the scan range when shooting MVCT.

A Experimental Study on Performance Improvement Factors of Used V4 Steel Pipe Support (재사용 V4 강재 파이프 서포트의 성능향상 요인에 관한 실험적 연구)

  • Choi, Myeongki;Park, Jongkeun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • It is considered that most of reusable pipe supports, which are used as formwork support posting at construction sites, do not meet the performance standard. Due to the use of reusable pipe supports that do not meet such performance standard the potential risk of collapse accident is increasing. Therefore, this study identifies the status of compliance with performance standard, and presents the requirements for improving quality control to prevent the collapse of pipe supports reused at the construction site. First, if the female thread of the product with no clearance and new support pin with the diameter of 12mm are replaced at the same time for use, it is considered that the performance will be improved. Second, as the quality performance during use can be improved in the case of larger thickness of inner diameter compared to the case of larger thickness of outer diameter, it is necessary to increase the inner pipe thickness greatly than the current thickness. Based on the results of this study, it is expected that the performance the reusable pipe support (V4) can be improved, if the diameter of the support pin is 12mm, the female thread has a small clearance, and the inner tube thickness is 2.3 ~ 2.7mm. In addition, it is considered that other performance improvement factors included in the study results could be used as important data for improving the performance of reusable pipe support.

An Experimental Study on Heat Flow Characteristics of Inflowing Cool Air in the Room (실내(室內) 유입(流入) 냉기(冷氣)의 열유동(熱流動) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Jang, Y.G.;Pak, J.W.;Pak, E.T.
    • Solar Energy
    • /
    • v.18 no.1
    • /
    • pp.57-67
    • /
    • 1998
  • A study on a buoyancy effect by the temperature difference between a inner room air and a inflowing cool air and also by Inlet velocity can contribute greatly to enhance performance of air conditioning system, so the study on the distribution characteristics of inflowed cool air is important to analyze the cool air storage in a room. For this study, in the real-sized model room, the temperature differences between inflowing cool air and inner room air are 10, 20, $30^{\circ}C$, and the inlet velocities of inflowing cool air are 1, 2, 3m/s respectively as dynamic parameters. Also, a anemos and a vane type diffuser are used as inlet geometric conditions. Following conclusions have been obtained through this study. 1) In case of the anemos type diffuser, it is found that a dimensionless temperature profile is low and the distribution of the inflowed cool air is uniform. and also, all diffuusers have a low temperature of the inner room as increasing the inlet velocity. 2) A mixing takes place rapidly in case of the anemos type diffuser when the temperature difference is low ${\Delta}T=10^{\circ}C$ and the inletvelocity is high V=3m/s. and the mixing degree is higher with the anemos type diffuser than the vane.

  • PDF

A Study on the implementation Strategy of the Next Generation Cadastral Information Service - Focus on the Case of Korea Cadastral Survey Corporation - (차세대 지적정보서비스 구현 전략 연구 - 대한지적공사 사례를 중심으로 -)

  • Lee, Bo-Mi;Lee, Yong-Mun
    • Spatial Information Research
    • /
    • v.16 no.1
    • /
    • pp.101-112
    • /
    • 2008
  • This study aims to show why we have to introduce SOA paradigm in the Cadastral Information System for coping with domestic and foreign IT environments flexibly and strengthening inner capability. We search the trend of up-to-date IT paradigm such as Enterprise GIS, SOA and etc. from this, we worked out the concept of Cadastral Information System. we also could see the introduction case of the domestic and foreign next generation Cadastral Information System, there is implications for us. also, we analysis the general condition about information system which KCSC(Korea Cadastral Survey Corporation) own in a general way and estimate the SOA level degree for each information system. and on that base, we set up SOA loadmap for implementation the next generation of Cadastral Information Service. This is an important step for building ideal future information systems which KCSC hope to be. For realizing this, we focus our inner capability on integration without duplicate and re-using the inner information infra.

  • PDF

Development of an Assumed Strain Shell Element for the Three Dimensional Construction Stage Analysis of PSC Bridge (PSC 교량의 3차원 시공 중 해석기법을 위한 가정된 변형률 쉘 요소 개발)

  • Kim, Ki-Du;Song, Sak Suthasupradit;Hwang, Hyun-Jin;Park, Jae-Gyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.108-117
    • /
    • 2010
  • The frame element is commonly used for construction stage analysis PSC bridges. However, the frame element does not show sufficient information in the curved PSC box bridges. For the case of curved PSC bridges, the deformations in the inner and outer web are different. In this case, the different jacking forces are required in the inner and outer webs. And it is impossible to calculate different jacking forces in the inner and outer webs if we use the frame element for construction stage analysis. In order to overcome this problem, the use of shell element is essential for a three-dimensional construction stage analysis of PSC bridges. In the following, the formulation of an assumed strain shell element and its application of PSC box girder bridge analysis are presented.

The Stress Distribution around a Circular Hole Reinforced by a Ring of Different Material in a Plate under Biaxial Loading (이질원환(異質圓環)으로 보강(補强)된 원형(圓形)구멍 주위(周圍)에서의 응력분포(應力分布))

  • S.J.,Yim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.6 no.1
    • /
    • pp.43-67
    • /
    • 1969
  • The effect of a circular hole reinforced by a ring of different material in a plate under biaxial loadings is considered. In this problem, an infinitely large flat is assumed. The reinforcing ring is of uniform rectangular cross-section of same thickness as the plate. The outer boundary of the ring is cemented to the inner boundary of the hole in the plate. The plate is subjected to hydrostatic tension and pure shear loadings. The stress distribution around the hole is obtained by means of the two dimensional theory of elasticity. To conform the validities of above solutions, a series of photo-elastic stress analysis for a composite model was carried out. Fair agreements were observed between two sets of values. The conclusions arrived at are as follows: 1) The theoretical solutions are exact ones for the case of infinitely large flat plate. 2) The solutions can be used for most case of engineering problem if the bonding between the plate and ring is perfect. 3) If the ratio of Young's moduli of the ring and the plate is increased, the stresses in the plate decrease whereas those in the ring increase. 4) The stress concentration near the hole has localized effect. 5) Under hydrostatic tension, maximum principal stress and maximum shear stress increase as the ratio of inner and outer diameters of the ring increases. 6) Under pure shear, the stresses depend upon angular orientations of the points and maximum principal stress and maximum shear stress appear at 45 degree. They increase as the ratio of inner and outer diameters of the ring increases.

  • PDF

A Necropsy Case of the Huge Pseudo-diverticulous Cyst at the Rumen of a Cattle (소의 제1위(第一胃)에 형성(形成)된 거대(巨大)한 가성게실(假性憩室)에 관(關)한 일부검례(一部檢例))

  • Bak, Ung Bok
    • Korean Journal of Veterinary Research
    • /
    • v.5 no.1
    • /
    • pp.27-30
    • /
    • 1965
  • In a cattle which had died of extreme emaciation caused by cachexic condition, a huge cyst of $45{\times}35{\times}20$cm, in size was found at the rumen. The cyst having with the narrow stalk which ended in blind sac attached firmly to the rumen by fibrinous or fibrous adhesion and, contained the lightly yellowish, clear exudative fluid of about 20 l, in volume. Grossly, the thickness of the cyst wall was 10~14mm, and its inner portion of the half was very rigid and colored with milky white in contrast with soft and edematous outer portion of the half. Microscopically the inner portion of the cyst wall was consisted of scarred fibrous tissue and possessed at its inner margin a little amount of the muscle fibers which had degenerated passably. These were confirmed as the muscle fibers in specific staining property by Van-Gieson's and Mallory-Azan stain. On regarding to above findings of gross and microscopic pictures, it was considered to be a pseudo-diverticulous cyst composed of the serosa and the muscle layer deriving from the wall of the rumen. And it was suggested that the cyst had been growing up to big size by storage of the plenty exudate arisen from its wall and was separated from the rumen at the end of its stalk.

  • PDF

An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구)

  • 황승식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

A Study on the Power Loss Cost of Inner-Grid in the Offshore Wind Farm (해상풍력단지 내부그리드의 전력손실비용에 관한 연구)

  • Shin, Je-Seok;Kim, Sung-Yul;Bae, In-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.72-77
    • /
    • 2014
  • The cross-section area of cable in the Offshore Wind Farm (OWF) is smaller than that in the onshore wind farm. Because the power loss in OWF is large relatively, the power loss is a key element for the economic evaluation of OWF design. The availability of wind turbine in OWF and the size of OWF are larger than those of onshore wind farm. If the economic evaluation of OWF ignores the availability of wind turbines, the power loss cost of OWF is overpriced. Since there are so many wind turbines, also, the calculation of power loss should be more accurate. In this paper, a method to calculate power loss is proposed for the design of big and complex inner-grid in OWF. The 99.5MW OWF is used for case study to see what effect the proposed method have on the power loss cost.