ANALYTICAL STUDY ON EVAPORATIVE COOLING POTENTIAL AND POWER GAINS OF AIR COMPRESSORS BY INLET FOGGING (입구공기 안개법에 의한 공기압축기의 증발냉각도와 출력이득에 관한 연구)

  • Suryan, Abhilash;Kim, Dong-Sun;Lee, Hae-Dong;Kwon, Joon-Kyeong;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2637-2641
    • /
    • 2008
  • The ever increasing demand for power and the shortages encountered during summer calls for the implementation of strategies for power saving in industry. Inlet fogging of gas turbine engines is quite popular due to the ease of installation and the relatively low initial cost compared to other inlet cooling methods. In the present investigation, a detailed analysis is carried out on the basis of coincident wet bulb and dry bulb temperature data of a compressed air plant from April to October, 2007 to determine the evaporative cooling potential for the period. The power gain that can be obtained by employing inlet fogging of the air compressors is analyzed based on the real climatic data at several sites in Korea. An experimental set-up was constructed and tests were carried out with the standard impaction pin nozzle. The experimental results were found to match with the theoretical calculations.

  • PDF

Flow Characteristic with Distance of Inlet Port and Rotating Length of Fluid in the Double Heat Exchanger (이중관 열교환기의 유체 유입위치와 회전길이에 따른 유동특성)

  • Lee, Seung-Ha;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.51-57
    • /
    • 2013
  • The length and position of the inlet port on the double tube heat exchanger is analyzed by CFX ver.11 for studying the characteristic of its flow distribution. When the boundary conditions of the inlet temperature and mass flow rate were each $20^{\circ}C$ and 10 ~ 50 kg/min, 3 models that are based on the distance between the inlet port and the center of the heat exchanger(0, 5.025, 10.05 mm) were analyzed to find the uniformity of the flow rate. Based on the flow rate, 4 lengths (23.723, 33.890, 44.057, 57.274 mm) were used to study the flow distribution according to Reynolds Number. The results show that, when the distance from the inlet to the position of the center of the heat exchanger is 10.05 mm and the length is 57.274 mm, the flow distribution is the most unified.

Establishing the Models for Optimized Design of Water Injection in Boilers with Waste-heat-recovery System (가습연소 폐열회수 보일러의 물분사 설계모델 구축에 관한 연구)

  • Shin, Jaehun;Moon, Seoksu
    • Journal of ILASS-Korea
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2021
  • In order to improve the overall efficiency and meet the emission regulations of boiler systems, the heat exchanging methods between inlet air and exhaust gas have been used in boiler systems, named as the waste-heat-recovery condensing boiler. Recently, to further improve the overall efficiency and to reduce the NOx emission simultaneously, the concept of the water injection into the inlet air is introduced. This study suggests the models for the optimized design parameters of water injection for waste-heat-recovery condensing boilers and performs the analysis regarding the water injection amount and droplet sizes for the optimized water injection. At first, the required amount of the water injection was estimated based on the 1st law of thermodynamics under the assumption of complete evaporation of the injected water. The result showed that the higher the inlet air and exhaust gas temperature into the heat exchanger, the larger the amount of injected water is needed. Then two droplet evaporation models were proposed to analyze the required droplet size of water injection for full evaporation of injected water: one is the evaporation model of droplet in the inlet air and the other is that on the wall of heat exchanger. Based on the results of two models, the maximum allowable droplet sizes of water injection were estimated in various boiler operating conditions with respect to the residence time of the inlet air in the heat exchanger.

The Effect of Load Variation on the Performance of an Injection Heat Pump with an Economizer (이코너마이저 적용 열펌프 시스템의 부하변화에 따른 성능 특성 연구)

  • Choi, Jong Min;Park, Yong-Jung;Kang, Shin-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2014
  • Heat pumps have received a fair amount of attention all over the world for their high efficiency and low environmental impact. Employing heat pumps for residential heating and cooling produces only about 2038 kg-$CO_2$/year, an amount which is less than half that of conventional boiler systems. However, the use of single-stage heat pumps becomes uneconomical when they are operated at very low evaporating temperature or high condensing temperature. Two-stage heat pumps systems can be used successfully for low or high temperature applications. In this paper, the experimental study on the performance of two-stage heat pump with an economizer was executed in heating mode. When the secondary fluid inlet temperature to the indoor heat exchanger increased, the COP enhancement rate of two-stage heat pump with an economizer was increased. For all outdoor inlet temperature conditions, the performance of the heat pump with an economizer was higher than it without an economizer.

Thermodynamic Performance Characteristics of Transcritical Organic Rankine Cycle Depending on Source Temperature and Working Fluid (열원온도와 작동유체에 따른 초월임계 유기랭킨사이클의 열역학적 성능 특성)

  • Kim, Kyoung Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.699-707
    • /
    • 2017
  • This study presents a comparative thermodynamic analysis of subcritical and transcritical organic Rankine cycles for the recovery of low-temperature heat sources considering nine substances as the working fluids. The effects of the turbine inlet pressure, source temperature, and working fluid on system performance were all investigated with respect to metrics such as the temperature distribution of the fluids and pinch point in the heat exchanger, mass flow rate, and net power production, as well as the thermal efficiency. Results show that as the turbine inlet pressure increases from the subcritical to the supercritical range, the mismatch between hot and cold streams in the heat exchanger decreases, and the net power production and thermal efficiency increase; however, the turbine size per unit power production decreases.

Effect of Inlet Temperature and CO2 Concentration in the Fresh Charge on Combustion in a Homogeneous Charge Compression Ignition Engine Fuelled with Dimethyl Ether (Dimethyl Ether 예혼합 압축 착화 엔진에서 흡기중 CO2 농도와 흡기온도 변화가 연소에 미치는 영향)

  • Bae, Choong-Sik;Jang, Jin-Young;Yeom, Ki-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.6 s.261
    • /
    • pp.514-521
    • /
    • 2007
  • This study focused on the effects of the $CO_2$ gas concentration in fresh charge and induction air temperature on the combustion characteristics of homogeneous charge compression ignition with dimethyl ether (DME) fuel, which was injected at the intake port. Because of adding $CO_2$ in fresh charge, start of auto-ignition was retarded and bum duration became longer. Indicated combustion efficiency and exhaust gas emission were found to be worse due to the incomplete combustion. Partial burn was observed at the high concentration of $CO_2$ in fresh charge with low temperature of induction air. However, indicated thermal efficiency was improved due to increased expansion work by late ignition and prolonged bum duration. Start of auto-ignition timing was advanced with negligible change of burn duration, as induction air temperature increased. Burn duration was mainly affected by oxygen mole concentration in induction mixture. Bum duration was increased, as oxygen mole concentration was decreased.

An Experimental Study of PV/Thermal Combined Collector Module (평판형 액체식 PVT 모듈의 성능 실험 분석)

  • Kang, Jun-Gu;Kim, Jin-Hee;Kim, Jun-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.780-785
    • /
    • 2009
  • The photovoltaic/thermal collectors (PV/T collectors) combine the solar thermal collector and photovoltaic modules. They can produce thermal energy in the form of hot air or hot water, and converts solar radiation into electricity. The collecctors can improve the electrical performance of PV modules as the heat from the PV module carried away by the thermal part of the system keeping temperatures lower. The basic water cooled PVT collector has metallic water pipes attached to the back of a PV collector. There are main parameters affecting the performance (electrical and thermal) of PVT collectors. This paper analyzed the experimental performance of glazed water PVT module, considering the parameters of solar radiation, inlet water temperature and ambient temperature. It found that solar radiation is the dominant factor for the electrical performance of the collector, and for the thermal performance the inlet water temperature and ambient temperature appeared to be more related.

  • PDF

Experimental Study on the Performance of an Air-Cooling System for Telecommunication Equipment (통신장비용 공냉형 냉각시스템의 성능 특성에 대한 실험적 연구)

  • Jeon, Jong-Ug;Choi, Jong-Min;Heo, Jae-Hyeok;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.323-328
    • /
    • 2005
  • The objective of this study is to analyze the cooling performance of an air- cooling system for telecommunication equipment. Temperature variation and capacity were measured in an actual unit for telecommunication equipment. In addition, the cooling performance was measured by installing a silicon rubber heater as a heat source in a cabinet. The standard thermal load for telecommunication equipment was approximately 293 W, and the maximum temperature of the heated surface was $64.5^{\circ}C$. The average and maximum temperatures of the heated surface were proportional to the inlet air temperature. When the heat load increased from 293 W to 400 W, the maximum temperature of the heated surface was higher than $64.5^{\circ}C$ even though the inlet air temperature decreased from 25 to $11^{\circ}C$.

  • PDF

A Study on Remodeling for Solar driven $NH_3/H_2O$ absorption chiller (태양열 구동 $NH_3/H_2O$ 흡수식 냉동기 리모델링 연구)

  • Shin, You-Soo;Maeng, Ju-Sung;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.37-43
    • /
    • 2003
  • The aim of this research is to study the feasibility of the solar(hot fluid) driven $NH_3/H_2O$ absorption chiller, made by re-manufacturing of Gas fired $NH_3/H_2O$ absorption chiller. This experimental study is performed with the temperature of the inlet hot fluid of generator. In order to determine the inlet temperature of the generator, which gives maximum COP, the experimental data are obtained with various hot fluid supply temperature in range of $130\sim170^{\circ}C$. Remodeled chiller is operated with periodical cooling effect, which due to mixture subcooled pool boiling, then the COP is evaluated in average. The maximum COP$(\sim0.36)$ is at $160^{\circ}C$. The temperature is stable operation temperature range of typical vacuum collector. It offers a feasibility of solar driven $NH_3/H_2O$ absorption chiller.

An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier (베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구)

  • Lee, Heung-Ju;Chang, Young-Soo;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.508-516
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. Failure modes in this study include refrigerant leakage, decrease in mass flow rate of the chilled water and cooling water, and sensor error of the cooling water inlet temperature. It is possible to detect and diagnose faults in this study by adopting FDD algorithm using only four parameters(compressor outlet temperature, chilled water inlet temperature, cooling water outlet temperature and compressor power consumption). Refrigerant leakage failure is detected at 20% of refrigerant leakage. When mass flow rate of the chilled and cooling water decrease more than 8% or 12%, FDD algorithm can detect the faults. The deviation of temperature sensor over $0.6^{\circ}C$ can be detected as fault.