DOI QR코드

DOI QR Code

Flow Characteristic with Distance of Inlet Port and Rotating Length of Fluid in the Double Heat Exchanger

이중관 열교환기의 유체 유입위치와 회전길이에 따른 유동특성

  • Lee, Seung-Ha (Department of Mechanical Engineering, Korea University) ;
  • Cha, Dong-An (Energy System R&D Group, Korea Institute of Industrial Technology) ;
  • Kwon, Oh-Kyung (Energy System R&D Group, Korea Institute of Industrial Technology)
  • 이승하 (고려대학교 기계공학과) ;
  • 차동안 (한국생산기술연구원 에너지시스템연구그룹) ;
  • 권오경 (한국생산기술연구원 에너지시스템연구그룹)
  • Received : 2013.03.28
  • Accepted : 2013.05.20
  • Published : 2013.08.31

Abstract

The length and position of the inlet port on the double tube heat exchanger is analyzed by CFX ver.11 for studying the characteristic of its flow distribution. When the boundary conditions of the inlet temperature and mass flow rate were each $20^{\circ}C$ and 10 ~ 50 kg/min, 3 models that are based on the distance between the inlet port and the center of the heat exchanger(0, 5.025, 10.05 mm) were analyzed to find the uniformity of the flow rate. Based on the flow rate, 4 lengths (23.723, 33.890, 44.057, 57.274 mm) were used to study the flow distribution according to Reynolds Number. The results show that, when the distance from the inlet to the position of the center of the heat exchanger is 10.05 mm and the length is 57.274 mm, the flow distribution is the most unified.

Keywords

References

  1. K. I. Choi, K. Y. Yoon, J. T. Oh, K. W. Park and H. K. Oh, 2000, "Development of High Efficient Heat Pump using Seawater Heat Source for Indoor Culture System(1)", 2000 Summer Annual Conference of SAREK, pp. 526-531.
  2. K. I. Choi, K. Y. Yoon, Y. S. Son, J. T. Oh and H. K. Oh, 2000, "Development of High Efficient Heat Pump using Seawater Heat Source for Indoor Culture System(2)", 2000 Winter Annual Conference of SAREK, pp. 406-410.
  3. S. Wongwises and M. Polsongkram, 2006, "Evaporation Heat Transfer and Pressure Drop of HFC-134a in a Helically Coiled Concentric Tube-in-Tube Heat Exchanger, Int. Heat and Mass Transfer, Vol. 49, pp. 658-670. https://doi.org/10.1016/j.ijheatmasstransfer.2005.08.017
  4. S. Wongwises and M. Polsongkram, 2006, "Condensation Heat Transfer and Pressure Drop of HFC-134a in a Helically Coiled Concentric Tube-in-Tube Heat Exchanger, Int. Heat and Mass Transfer, Vol. 49, pp. 4386-4398. https://doi.org/10.1016/j.ijheatmasstransfer.2006.05.010
  5. O. K. Kwon and W. S. Seol, 2013, "Research and Development of Sea Water Heat Pump", Journal of the Korean Society for Power System Engineering, Vol. 17, No. 1, pp. 7-13. https://doi.org/10.9726/kspse.2013.17.1.007
  6. D. A. Cha, S. H. Lee, O. K. Kwon and W. S. Seol, 2012, "Flow Characteristics of the Double Heat Exchanger with Distance of Inlet Port and Rotating Length of Fluid", Proceeding of the KSME, pp. 2787-2792.
  7. J. D. Kim and W. S. Seol, 2009, "An Experimental Study on Heat Exchanger for Optimizing Fouling Auto Removal Apparatus using Cleaning Ball", 2009 Spring Annual Conference of KSPSE, pp. 244-249.
  8. ANSYS Inc. CFX Release 11.0 Training Manual.
  9. M. S. Kim and K. S. Lee, 2006, "Performace Analysis on a Multi-pass Multi-branch Heat Exchanger According to Pass Arrangement", Trans. of the KSME B, Vol. 30, No. 8, pp. 741-748.
  10. M. J. Choi, O. K Kwon and J. H. Yun, 2009, "Flow Distribution and Heat Transfer Characteristic of the Microchannel Waterblock with Different Shape of Inlet," Trans. of the SAREK, Vol. 21, No. 7, pp. 386-393.
  11. J. T. Choi, O. K Kwon, J. H. Yun and Y. C. Kim, 2011, "A Numerical Study of the Effects of Heat Transfer and Fluid Flow on Tube Insertion Length in Computer-Cooling Radiators", Trans. of the KSME(B), Vol. 35, No. 2, pp. 145-152. https://doi.org/10.3795/KSME-B.2011.35.2.145

Cited by

  1. Determining Design Parameters and an Optimal Design Method for Coaxial Geothermal Heat Exchangers Using Verification Experiments and GLHEPro Numerical Analysis vol.19, pp.2, 2013, https://doi.org/10.9798/kosham.2019.19.2.265
  2. Experimental Research on a Heat Pump Applying a Ball-Circulating Type Automatic Fouling Cleaning System for Fish Farms vol.13, pp.22, 2013, https://doi.org/10.3390/en13225856