• Title/Summary/Keyword: Industrial Noise

Search Result 1,261, Processing Time 0.03 seconds

Preliminary Study on GIS Mapping-based Fine Dust Measurement in Complex Construction Site (단지조성공사 내 드론을 활용한 GIS 맵핑 기반 미세먼지 측정 시스템 기초 연구)

  • Lee, Jaeho;Han, Jae Goo;Kim, Young Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.319-325
    • /
    • 2021
  • A fine dust measurement using drones is becoming an increasingly common technology, and air pollutants can be identified through dust monitoring in partial industrial areas. A station for measuring fine dust provides information at large construction site offices. On the other hand, it was difficult to check the fine dust in the pollutant source accurately. Therefore, the drone took measurements directly after been placed at the site. While measuring fine dust, monitoring noise occurred due to the influence of the drone's down-wind during landing, but the measurements were similar to the numerical value of the grounded pollution source on the height of 30 m. The field applicability to the study area has limitations in periodic updates using satellite images because the terrain was constantly changing due to considerable flattening fieldwork. Therefore, this study implemented a system that can reflect real-time field information through GIS mapping using drones.

A Study on the PM10 and CO2 Concentrations at Public Places (일부 실내공간에서 PM10과 CO2의 농도 특성에 관한 연구)

  • Jung, Joon-sig;Park, Duckshin;Kim, Jong bum;Song, Hyea-suk;Park, Hyung-kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4335-4347
    • /
    • 2015
  • The objective of this study was to investigate $PM_{10}$ and $CO_2$ concentrations in the classrooms of 286 elementary schools in Suwon, Ansan, and Hwaseong in the province of Gyeonggi between August 2008 and December 2012. By gaining an understanding of the environmental factors that influence these concentrations, this study also aimed to establish a management plan for indoor air quality in schools, which substantially affects the health of elementary students. When the schools were classified by region, no statistically significant difference in $PM_{10}$ concentration was observed. However, $PM_{10}$ concentration was relatively high in industrial areas and low in rural areas. No difference in $CO_2$ concentration was observed among the surveyed cities. Analysis of annual $PM_{10}$ concentration showed that the highest values for Suwon and Hwaseong occurred in 2008 and 2009, respectively (p<0.01). In the case of Ansan, the highest concentration occurred during 2009, but the difference was not significant compared to the other years. Analysis of the annual $CO_2$ concentration of each city shows no significant difference among the cities (p-value=0.366,0.730,0.210). According to a time series analysis of $PM_{10}$ and $CO_2$ by season, from autumn 2008 to winter 2012, $PM_{10}$ concentration was high during 2009, then it gradually decreased until 2012, and started to increase again. While no difference in annual $CO_2$ concentration was observed, the concentration had a tendency to be higher in spring and winter than in summer. By analyzing the relationship between $PM_{10}$ and $CO_2$ and the environmental factors (years of construction, average students of classroom, temperature, and humidity), it showed a significant negative correlation was found between $CO_2$ and the environmental temperature and humidity, at -0.329 and -0.188, respectively (p<0.01).

Detection of Spoilage Odors in Beef Using R-index and Pseudomonas Growth during Storage (쇠고기의 저장 중 R-index에 의한 부패취 발생시점과 Pseudomonas의 증식과의 비교 분석)

  • Byeon, Ko Eun;Park, Han Jo;An, Soo Rim;Hong, Kwang Won;Min, Sang Gi;Chung, Ku Young;Won, Kee Hoon;Lee, Seung Ju
    • Food Engineering Progress
    • /
    • v.13 no.2
    • /
    • pp.117-121
    • /
    • 2009
  • Detection of spoilage odors from beef during storage was investigated using sensory evaluation with R-index, and microbial assay for Pseudomonas. Beef samples were tested to measure the flavor changes, which were converted to R-index, and the Pseudomonas levels during storage. There was a steep rise in R-index until 36 hr after storage at 25$^{\circ}C$, and then a gentle rise from 48 hr, whereas, there was a steady rise in R-index in the whole range of storage at 5$^{\circ}C$. Detection time of spoilage odors according to R-index was statistically analyzed at $\alpha$=5% to be at 30.92${\pm}$3.47 hr and 169.80${\pm}$11.27 hr for 25 and 5$^{\circ}C$ storage, respectively, and analyzed at $\alpha$=1% to be 34.80${\pm}$4.01 and 176.41${\pm}$9.89 hr for 25 and 5$^{\circ}C$ storage, respectively. At the detection times of spoilage odors, the Pseudomonas levels were found to be almost the same, but less than 6-7 log CFU/g generally known as a standard level at occurrence of spoilage odors in beef. This indicated that some other factors than the Pseudomonas reactions could be associated with generation of spoilage odors.

Optical Communication and Sensing Modules for Plastic Optical Fibers (고분자광섬유용 광통신 및 센서 모듈)

  • Park, Byung-Wook;Yoon, Do-Young;Kim, Dong-Shik
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.558-564
    • /
    • 2009
  • POF(Polymer optical fiber) offers advantages of lighter, inexpensive, and easier to use over GOF(glass optical fiber). Its higher transmission loss and low bandwidth, however, make it suitable only for short distance networking such as LAN. The polymer materials and its synthesis technology of low transmission loss and the broader application for flexible POF are the two of many critical areas to be investigated more. In the current study, low-noise POF modules are developed and optimized with a low noise amplifier and low cost LED of 650 nm. In order to demonstrate the dynamic characteristics of the POF module for optical communication and sensing, we have built an image transfer module, optical transmission speed measurement module, optical transceiver for RS-232, and sound-transfer module, and the signal characteristics of them are evaluated. It is found that the module can be readily used for a quick and simple measurement of optical transfer speed. With help of analog amplifier, LED, and PD, sound and image transfers through a maximum 60 m optical waveguide have been confirmed. Real-time data transfer was also demonstrated in PID control, which is thought to be valuable to industrial plant design and control.

Color-Texture Image Watermarking Algorithm Based on Texture Analysis (텍스처 분석 기반 칼라 텍스처 이미지 워터마킹 알고리즘)

  • Kang, Myeongsu;Nguyen, Truc Kim Thi;Nguyen, Dinh Van;Kim, Cheol-Hong;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.4
    • /
    • pp.35-43
    • /
    • 2013
  • As texture images have become prevalent throughout a variety of industrial applications, copyright protection of these images has become important issues. For this reason, this paper proposes a color-texture image watermarking algorithm utilizing texture properties inherent in the image. The proposed algorithm selects suitable blocks to embed a watermark using the energy and homogeneity properties of the grey level co-occurrence matrices as inputs for the fuzzy c-means clustering algorithm. To embed the watermark, we first perform a discrete wavelet transform (DWT) on the selected blocks and choose one of DWT subbands. Then, we embed the watermark into discrete cosine transformed blocks with a gain factor. In this study, we also explore the effects of the DWT subbands and gain factors with respect to the imperceptibility and robustness against various watermarking attacks. Experimental results show that the proposed algorithm achieves higher peak signal-to-noise ratio values (47.66 dB to 48.04 dB) and lower M-SVD values (8.84 to 15.6) when we embedded a watermark into the HH band with a gain factor of 42, which means the proposed algorithm is good enough in terms of imperceptibility. In addition, the proposed algorithm guarantees robustness against various image processing attacks, such as noise addition, filtering, cropping, and JPEG compression yielding higher normalized correlation values (0.7193 to 1).

Analysis of Overviews of Working Environment Measurement and its Results in Korean Industry (우리나라 사업장의 작업환경측정 및 노출기준 초과실태 분석)

  • 김정호;원정일
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.53-61
    • /
    • 1996
  • The subject of this study was to analyse overviews of companies which exceed TLV by industry, hazardous factors, and to estimate the numbers of companies measured in 1993 and the implementation rate of working environment measurement by the act of industrial safety and health The result of this study was as follow. 1. The number of cases which exceed TLV was 5,937 companies. In distribution of excess companies by the scale of workers, small scale cases under the 49 workers were 3,150 companies(53.0%) of total cases, medium scale cases between 50 - 299 workers were 2,248 companies(37.9%), and large scale cases over 300 workers were 539 companies(9.1%). By the industry of excess companies, it was marked high rate in manufacture of fabricared metal products(except machinary and equipment), manufacture of textiles of each 1,048 companies(17.7%), and 1,018 companies(17.1%). By the area of excess companies, it was shown high rate in Kyeongki area marked 1,679 companies(28.3%) and Daegu-Kyeongbuk area were marked 1,417 companies (23.9%). By the hazardous factors of excess companies, noise was recorded high rate in 5,160 companies (86.9%), dust was shown in 1,245 companies(21.0%), organic solvent was marked 130 companies(7.9%). The number of excess factors by the company was 1.2. In this result, the more it was bigger scale companies, the more excess factors were much more and the more it was recorded higher rate in noise organic solvent heavy metals, etc. 2. The measured cases in institutes during 1994 were 1,596 companies, and excess cases were 157 companies(9.8%) among them. By the scale of workers, small scale cases under the 49 workers were 190 companies (17.9%) among 1,064 companies, cases of medium scale cases between 50-299 workers were 127 companies (27.9%) among 463 companies, and large scale cases over 300 workers were 31 companies(44.9%) among 69 companies. In this result industry of the highest rate shown was manufacture of basic metals in 20 companies exceeded among 53 companies (37.7%), and was manufacture of pulp, paper production in 14 companies exceeded among 40 companies(35.0%), and the excess rate were high in bigger scale. 3. Companies estimated by the data of excess cases and excess rate in 1993 were 30,474 implementation rate estimated for measurement of working environment was 34.3% of companies in korean industry. In this result, it was comparatively shown of measurement rate for the working environment in manufacture of pulp, paper product, manufacture of machinary and equipment n.e.c., and of high measurement rate and excess rate in manufacture of electrial machinary and apparatus, and manufacture of basic metals.

  • PDF

Optimal Control for Multiple Serial Sampling Systems (다중시리얼 샘플링 시스템의 최적제어)

  • Yeon Wook Choe
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.10
    • /
    • pp.771-782
    • /
    • 1991
  • In industrial multivariable plants, it is ofte the case that the plant outputs are measured in similar components not simultaneously but serially. In this paper, the problem of estimating the state vector of the plant based on the data obtained from such a measuring scheme is considered, and a special type of observer(referred to as a $'$multiple serial-sampling$'$ type observer) which renews its internal states whenever a new group of data is obtained is proposed. It is proved that such an observer can be constructed for almost every sampling period if the palnt is observable as a continuous-time multivariable system, and that the poles of the closed-loop system using the multiple serial-sampling type observer consist of the poles of the observer and those of the state feedback system. The behaviors of the observer and the closed-loop system are studied by simulation. The results of simulation indicate that a multiple serial-ampling type observer can estimate the state of the plant more accurately than the ordinary type observers and improve the closed-loop performance, especially, in the existence of measuring noise.ng noise.

  • PDF

Study on Developing Assessment Guideline for Safety and Performance of Electric Moxibustion Apparatus (전기식 온구기에 대한 안전성 및 성능 평가 가이드라인 개발 연구)

  • Yi, Seung-Ho;Kang, Jung-Won;Nam, Dong-Woo;Kim, Eun-Jung;Lee, Hye-Jung;Kim, Kap-Sung;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.75-86
    • /
    • 2010
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric moxibustion apparatus (class II medical device). Methods : We drafted the guideline for safety and performance assessment of electric moxibustion apparatus by referring the existing standards, guidelines and measurement data from commercially available products. Temperature characteristics such as maximum temperature and ramp time, and physical characteristics such as weight, noise and diameter were measured. User friendliness was also evaluated for commercial devices. Results : This guideline only can be applied to the electric moxibustion apparatus where moxa is being heated by electricity for medical proposes. Maximum temperature of higher than $50^{\circ}C$ can be achieved mostly. Ramp rate of temperature seems to be reliable. Control of temperature is needed to be improved. Moxa and its derivative products seem to be regulated for reliable temperature performance for clinical application. Requirements for design and development of electric moxibustion apparatus are suggested : temperature indicator, temperature control and its accuracy, safety measure, surge protection, user friendliness and instruction for use (IFU). Design recommendation of the reduction of noise level and energy loss are suggested for better products. Conclusions : We proposed a guideline for safety and performance assessment of electric moxibustion apparatus to improve the quality of relating products and aid their commercialization by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

Modified Empirical Formula of Dynamic Amplification Factor for Wind Turbine Installation Vessel (해상풍력발전기 설치선박의 수정 동적증폭계수 추정식)

  • Ma, Kuk-Yeol;Park, Joo-Shin;Lee, Dong-Hun;Seo, Jung-Kwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.846-855
    • /
    • 2021
  • Eco-friendly and renewable energy sources are actively being researched in recent times, and of shore wind power generation requires advanced design technologies in terms of increasing the capacities of wind turbines and enlarging wind turbine installation vessels (WTIVs). The WTIV ensures that the hull is situated at a height that is not affected by waves. The most important part of the WTIV is the leg structure, which must respond dynamically according to the wave, current, and wind loads. In particular, the wave load is composed of irregular waves, and it is important to know the exact dynamic response. The dynamic response analysis uses a single degree of freedom (SDOF) method, which is a simplified approach, but it is limited owing to the consideration of random waves. Therefore, in industrial practice, the time-domain analysis of random waves is based on the multi degree of freedom (MDOF) method. Although the MDOF method provides high-precision results, its data convergence is sensitive and difficult to apply owing to design complexity. Therefore, a dynamic amplification factor (DAF) estimation formula is developed in this study to express the dynamic response characteristics of random waves through time-domain analysis based on different variables. It is confirmed that the calculation time can be shortened and accuracy enhanced compared to existing MDOF methods. The developed formula will be used in the initial design of WTIVs and similar structures.

Development of IoT-based App Service for Non-face-to-face Management of Library Reading Rooms (도서관 열람실의 비대면 관리를 위한 사물인터넷(IoT) 기반 앱 서비스 개발)

  • Hong-hyeon Choi;Seung-hoon Lee;Jeong-du Lee;Jin Yu;Seong-hoon Jeong;Joon-hwan Shim
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.6
    • /
    • pp.562-568
    • /
    • 2021
  • Seat reservations and civil complaints in the library reading room have been done face-to-face by managers, and efficient management has been difficult. In addition, there is a problem that it is difficult to take action in the event of a civil complaint due to user inconvenience, such as a noise problem between users in the reading room. In this study, an online reservation system was developed for efficient management of seats in the library reading room so that it could be serviced non-face-to-face. In addition, when using the library reading room, it is possible to apply for non-face-to-face civil complaints when complaints occur due to noise problems between users, loss of belongings, and snoring during the user's sleep. Managers can smoothly manage library reading rooms through non-face-to-face inconvenience reports. It is possible to increase the satisfaction of using the library by resolving the inconvenience of users. The developed service app allows seat reservations and anonymous inconvenience reports. The administrator can check the received inconvenience report and warn the user of the seat with an IoT sensor-based LED. When corrective action is completed, the result of the action may be fed back to the reporter.