• Title/Summary/Keyword: Indoor Noise Limit

Search Result 11, Processing Time 0.024 seconds

Study of the Indoor Noise Limit for Naval Vessels Considering the Satisfaction of the Crew (승조원의 만족도를 고려한 함정의 함내소음 기준 분석)

  • Han, Hyung-Suk;Park, Mi-Yoo;Cho, Heung-Gi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.4
    • /
    • pp.589-597
    • /
    • 2010
  • The indoor noise of the naval vessel is very important considering hearing protection, improvement of working environment and easily communication between crews. When the environment of the naval vessel suffering from the noise is considered, it is very important to be quiet in the living area where the crews have a rest sufficiently. In addition, the noise of the working area should be reduced in order to increase working efficiency. Therefore, in this research, the satisfactions about the indoor noise are survey for crews working in a naval vessel. Through this survey, the relationship between the indoor noise and crew's satisfaction about it can be found. As a result, the limit of sound pressure level which almost all crew can be satisfied with the indoor noise about their living and working area is suggested base on the survey in this research.

Psycho-acoustic Evaluation and Analysis of the Indoor Noise in Cabins of a Naval Vessel to Specify its Allowable Limit (함정의 실내소음 허용기준 설정을 위한 청감평가 및 분석)

  • Hong, Hyun-Soo;Shim, Sang-Ryul;Han, Hyung-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.650-656
    • /
    • 2011
  • The noise inside a naval vessel is very important in considering the need for hearing protection, improving the working environment and maintaining good communications for crews living on board a naval vessel. The indoor noise of a ship usually is specified by the A-weighted sound pressure level, but other evaluating parameters are required to reflect human senses more effectively. This paper uses additional noise indices related to room acoustics, such as NR(noise rating), NC(noise criterion), RC(room criterion), PSIL(preferred speech interference level) and loudness level to evaluate the noise inside cabins on a naval vessel. Using these psychological noise indices, allowable limit of noise level in cabins is suggested through psycho-acoustic evaluation for the noise in cabins.

A Study on the Indoor Noise Limits of Apartment Houses from the Road Traffic Noise (도로교통소음에 대한 공동주택 내부소음 기준설정에 관한 연구)

  • Lee, Ju-Yeob;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1084-1091
    • /
    • 2005
  • The indoor noise limit for road traffic noises is needed to secure comfortable acoustical quality in apartment houses. To achieve this goal, psycho-acoustic experiments were carried out with road traffic noise sources modulated by the transmission loss characteristics of the external windows. Finally, a correlation analysis between noise rating index and subjective responses, and an analysis of satisfactory percentage of the dose-response curves varied with respondents was conducted. As a result of this study, followings are suggested. (1) On correlation between dose level and psycho-acoustical response, the initial level of negative feeling is located on $40.1\~40.6\;L_{eq}$ dB(A), (2) On the degree of satisfaction to road traffic noise. near $35\;\%$ point being same dissatisfaction degree is to be assumed $40\~41$ dB(A) of indoor noise level presented into three vocabulary. It is suggested to be reasonable level of 40 dB(A) on the indoor noise limits for intruding road traffic noise. and it is appropriate to be the 5 dB level difference between grades. The results of this study may be used to evaluate the acoustic threshold level for road traffic noise or as a basis for specifying the desired acoustic environment of dwellings.

Subjective Evaluation of Transportation and Computer Noise (교통소음과 컴퓨터 소음의 감성반응에 대한 연구)

  • Jeong, Jeong-Ho;Jeon, Jin-Yong;Song, Hee-Su;Cho, Moon-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.547-552
    • /
    • 2002
  • The purpose of this study is to propose indoor noise level in residential buildings affected by transportation noise (road traffic, railway and air-craft noise) based on subjective evaluations, 30 subjects participated in the experiment to evaluate the noise. Experimental environment reproduced real living and office environment, and in asking subjects' annoyance to the noise. An experiment to investigate the subjective responses to various computer noises (CD-Rom, HDD, Fan) in office environment was also undertaken. The Result shows that the lower limit of transportation noise is $40{\sim}41dB(A)$ and upper limit is $55{\sim}60dB(A)$, whereas the lower limit of various computer noises is $36{\sim}40dB(A)$ and upper limit is $45{\sim}52dB(A)$.

  • PDF

Indoor Noise limits of Apartment Houses for Road Traffic Noise by Psycho-acoustic Experiment (청감실험을 통한 도로교통소음에 대한 공동주택 내부소음 기준설정 연구)

  • Lee, Ju-Yeob;Kim, Hang;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.83-86
    • /
    • 2005
  • The aim of this study is to establish the indoor noise limits of apartment houses for mad traffic noise. To achieve this goal, psycho-acoustic experiments were carried out with the mad traffic sound sources modulated by the transmission loss characteristics of the external windows. As a result of this study, followings are suggested. 1) On correlation between dose level and psycho-acoustical response, the initial level of negative feeling is located on $40.1{\sim}40.6$ Leq dB(A). 2) On the degree of satisfaction to road traffic noise, near 35% Point being same dissatisfaction degree is to be assumed $40{\sim}41$ dB(A) of indoor noise level presented into three vocabulary. It is suggested to be reasonable level of 40 dB(A) on the indoor noise limits for intruding road traffic noise, and it is appropriate to be the 5dB level difference between grades.

  • PDF

Airborne Sound Insulation Performance of Window and Indoor Noise Level in the Balcony Expanded Apartments

  • Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.61-67
    • /
    • 2015
  • Purpose: The balcony in the apartment is important space not only as a fire escape but also as a buffer for heat and sound insulation. However, with the legalization of balcony expansion for residential apartments in Korea in 2006, many households have eliminated the balcony space altogether to increase the inner space, often without sufficient consideration for the effects on the indoor environment. This study examined the sound insulation performance of exterior-facing windows in enclosed balconies and the changes in the indoor acoustic environment due to expansion to provide a basis for appropriate balcony expansion. The apartments for the field test were chosen where two balcony types can be compared, and the sound insulation performance for the eighteen balcony windows was measured. The windows installed were typical double window with thickness 16 mm or 22 mm. Measurements of the weighted standard sound pressure level difference showed a decrease of about 3 dB in sound insulation performance due to expansion. For common exterior noise levels of 70-85 dB(A), the indoor noise level can exceed 45 dB(A), the limit level regulated in Korea. However, it was found that the sound insulation performance of the window and the quality of the construction have more influence on indoor noise levels than balcony expansion itself.

Subjective Evaluation of Transportation and Computer Noise (교통소음과 컴퓨터 소음의 감성반응에 대한 연구)

  • Jeong, Jeong-Ho;Jeon, Jin-Yong;Song, Hee-Su;Cho, Moon-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.357.1-357
    • /
    • 2002
  • The purpose of this study is to propose indoor noise level in residential buildings affected by transportation noise (road traffic, railway and air-craft noise) based on subjective evaluations. 30 subjects participated in the experiment to evaluate the noise. Experimental environment reproduced real living and office environment, and in asking subjects' annoyance to the noise. (omitted)

  • PDF

Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System (바닥공조 시스템이 적용된 사무공간의 거주후 성능평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Jung, Hae-Kwon;Choi, Sun-Kyu;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

Noise Exposure according to the Time Activity Pattern and Duties of Firefighters (소방 공무원의 시간활동 양상과 직무에 따른 소음 노출 특성)

  • Lee, Lim-Kyu;Kang, Tae-Sun;Ham, Seung-Hon;Kim, Jung-In;Yang, Young-Suk;Yoon, Chung-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.94-101
    • /
    • 2011
  • Objectives: The purpose of this study is to evaluate the noise exposures of firefighters according to their time-dependent activity patterns. Methods: Personal exposure levels were measured for six days and nights using noise dosimeters; three days and nights for on-duty tasks, the other days and nights for off-duty activities. Results: The total amount of time spent in the workplace was 13,677 min (67%), outside areas 4,833 min (23%), in transit 1,002 min (5%), and other indoor area 807 min (4%) during a working period. However, during off-days they spent 10,858 min (76%) at home, 1,382 min (10%) outdoors, 1,225 min (9%) other indoors, and 493 min (3%) in transit. As a result of individual exposure levels, TWA did not exceed 90 dBA of the occupational exposure limit for the majority of the firefighters, whereas the levels of Lmax were 119 dBA, which were higher than the noise levels of firefighters in USA. Sometimes during dispatching the levels of Lpeak exceeded the ACGIH exposure standard (140 dBC). The Leq levels in transit were higher than the levels in home and other indoors even though the activity time is short. Conclusions: This paper characterized the noise exposure patterns of firefighters in Korea. We suggest that special noise sources, including sirens and speaker phones, should be readjusted to reduce noise exposure.

Study on Scalable Video Coding Signals Transmission Scheme using LED-ID System (LED-ID 시스템을 이용한 SVC 신호의 전송 기법에 관한 연구)

  • Lee, Kyu-Jin;Cha, Dong-Ho;Hwang, Sun-Ha;Lee, Kye-San
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.10B
    • /
    • pp.1258-1267
    • /
    • 2011
  • In this paper, using the indoor LED-ID communication system have researched for how to transmit video signals. In LED-ID communications use the LEDs for lighting features at the same time communication is an effective way to implement. This proposed system using Visible light(RGB) as way to transmit signals, depends on the mixture RGB, which decided the color of light, moreover, each things determined their performance. However, if the video signal were fixed allocated RGB to transmit such as the original system, the importance of the each signals a different occur the limit on the quality of the video than SVC signals. In order to solve this problem in this paper, according to the RGB mixture ratios analyze the performance for the White LED, which analyzed based on allocating the SVC signal by transmitting to improve the quality of the video was about how researched.