• Title/Summary/Keyword: Indoor Air

Search Result 2,348, Processing Time 0.03 seconds

Development of Real-time Monitoring Platform for Indoor Air Quality Using Air Quality Sensors (AQ센서를 활용한 실내 대기 질 실시간 모니터링 플랫폼 개발)

  • Oh, Sang-Heon;Kim, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.206-209
    • /
    • 2018
  • According to data released by the WHO(World Health Organization), the death toll from indoor air pollution in 2016 was about 3.8 million. While many people are aware of outdoor air pollution, indoor air pollution is getting less attention. Recently, however, indoor air pollution has also become a big problem, raising many issues. Frequent indoor activities such as cooking and heating produce various pollutants, which can cause children and elderly with weak immune systems to be exposed to pollutants, which can cause serious health problems such as poor lung function and respiratory diseases. Therefore, in this paper, the IoT(Internet of Things) platform that measures and monitors indoor air quality using AQ(Air Quality) sensors is developed so that data can be monitored in real time through applications and reactive web.

  • PDF

Design and Implementation of Space Adaptive Autonomous Driving Air Purifying Robot for Green Smart Schools (그린 스마트 스쿨을 위한 공간 적응형 자율주행 공기청정 로봇 설계 및 구현)

  • Oh, Seokju;Lee, Jaehyeong;Lee, Chaegyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.77-82
    • /
    • 2022
  • The effect of indoor air pollution on the human body is greater and more dangerous than outdoor air pollution. In general, a person stays indoors for a long time, and in a closed room, pollutants are continuously accumulated and the polluted air is better delivered to the lungs. Especially in the case of young children, it is very sensitive to indoor air and it is fatal. In addition, methods to reduce indoor air pollution, which cannot be ventilated with more frequent indoor activities and continuously increasing external fine dust due to Covid 19, are becoming more important. In order to improve the problems of the existing autonomous driving air purifying robot, this paper divided the map and Upper Confidence bounds applied to Trees(UCT) based algorithm to solve the problem of the autonomous driving robot not sterilizing a specific area or staying in one space continuously, and the problem of children who are vulnerable to indoor air pollution. We propose a space-adaptive autonomous driving air purifying robot for a green smart school that can be improved.

Adsorption properties of non-cement boards using adsorbent (흡착재를 활용한 흡착형 무시멘트 보드의 흡착 특성)

  • Pyeon, Su-Jeong;Lim, Hyun-ung;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.226-227
    • /
    • 2018
  • Recently, as the interest of the government and the public on energy saving has increased, the airtightness of buildings has been improved to improve the insulation performance of buildings. However, indoor air pollution due to increase of pollution source in indoor space and lack of ventilation is increasing and interest in indoor air quality is increasing. In 2003, the Ministry of Environment enacted and promulgated the Act on Indoor Air Quality Control in Multi-use Facilities. Radon is a naturally occurring radioactive inert gas with colorless, tasteless and odorless nature. The concentration is high in a room where radon can not escape. Although lononggas is naturally occurring, it is not interested in living environment, but it is easily inhaled through human body through respiration and causes lung cancer in long-term exposure. Therefore, this study intends to carry out an experiment for the reduction of radon gas, which is the first carcinogen in indoor air pollution sources.

  • PDF

Experimental Study on the Effect of Ventilation System on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 강제환기장치 사용에 따른 실내공기질 개선효과 실증연구)

  • Lee, Gyu-Dong;Park, Young-Sok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.143-146
    • /
    • 2006
  • There has been growing concern regarding IAQ(Indoor Air Quality) recently, and IAQ problems from the air-tightness and use of chemical materials addition to the building materials have become increasingly important factors in the built environment. Ventilation is supposed as the solution of healthy indoor quality, and Korea government requests that all new apartment buildings must have a ventilation system as a matter of duty since January, 2006. The purpose of this study is to investigate the indoor concentration change of VOCs include the Formaldehyde according to many different ventilation supply types. Results showed that the reduction effect of target pollutants by the ventilation system was very slight. The cause of these results was attribute to increase the emission rate of building materials by increasing the ventilation rate.

  • PDF

A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms (천장 카세트형 냉·난방기에 의해 형성되는 학교 교실의 실내 열환경 및 공기환경의 개선에 대한 연구)

  • Chang, Hyun-Jae;Lee, Ha-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.141-148
    • /
    • 2012
  • Ceiling cassette type air conditioner has been a main stream as a heating/cooling system recently in school, Korea. In this study, indoor thermal environments made by ceiling cassette type air conditioner were investigated by CFD simulation. Concentrations of $CO_2$ were investigated by a field measurement. Indoor thermal environment with the velocity inlet angle of $45^{\circ}$ from the ceiling in heating season was very ununiform so that thermal area was divided into two parts those the one is window side which is cold, and the other is corridor side which is hot. In cooling season under the same condition, there are areas too hot or too cold. If the velocity inlet angle is set in $30^{\circ}$ from the ceiling, indoor thermal environments was improved greatly in cooling season and heating season, too. Also, from the field measurement of $CO_2$ concentrations, it was suggested to install ventilators with proper air volume considered the number of class students.

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at Kwangju Area

  • Son, Bu-Soon;Song, Mi-Ra;Yang, Won-Ho;Chung, Young-Dall;Pack, Jong-An
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.373-377
    • /
    • 2005
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals and from chemicals are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCS and particulate matter($PM_{10}$) during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and PM lo were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor sources and outdoor sources. Therefore, proper management methods should be taken to improve the indoor air quality in beauty shops.

  • PDF

Review of Metal Oxide-based Formaldehyde Gas Sensor to Measure Indoor Air Quality (실내 대기질 진단을 위한 금속산화물 기반 폼알데하이드 가스센서 연구 동향)

  • Kim, Yoon Hwa;Koo, Won-Tae;Jang, Ji-Soo;Kim, Il-Doo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.377-384
    • /
    • 2019
  • People currently spend more than 80% of their time indoors; therefore, the management of indoor air quality has become an important issue. The contamination of indoor air can cause sick house syndrome and various environmental diseases such as atopy and nephropathy. Formaldehyde gas, which is the main contaminant of indoor air, is lethal even with microscopic exposure; however, it is commonly used as an adhesive and waterproofing agent for indoor building materials. Therefore, there is a need for a gas sensor capable of detecting trace amounts of formaldehyde gas. In this review, we summarize recent studies on metal oxide-based semiconductor gas sensors for formaldehyde gas detection, methods to improve the gas-sensing properties of metal oxides of various dimensions, and the effects of catalysts for the detection of parts-per-billion level gases. Through this, we discuss the necessary characteristics of the metal oxidebased semiconductors for gas sensors for the development of next-generation sensors.

Purification Ability of Indoor Plants for Volatile Organic Compounds (VOCs) (실내식물의 휘발성유기화합물질 정화에 관한 연구)

  • Park, Soyoung;Kim, Jeoung;Jang, Young-Kee;Sung, Kijune
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.6
    • /
    • pp.417-423
    • /
    • 2006
  • The purification ability of indoor plants for volatile organic compounds was investigated. Philodendron selloum and Spathiphyllum sp. were tested for removal of toluene and trichloroethylene in the artificially contaminated reactor under laboratory conditions. Each plant was placed in right side of the reactor and the TCE and toluene concentration change with time were monitored. In the reactor with Philodendron, the TCE concentrations of left and right sides were compared to examine the removal effects by plant. In the reactor with Spathiphyllum, air was circulated before sampling, and thus average removal effects by plants on target VOC were observed. Both plants showed clear effects on removal of VOCs from contaminated indoor air. The removal efficiency of Philodendron and Spathiphyllum were similar and showed 30 - 46% and 31 - 47% of purification effects, respectively. The results of this study showed that air purification using plants is an effective means of reduction on indoor VOCs concentration level and reduce related health risk though, supplementary purifying aids or proper ventilation were also suggested.

A Study on Emission Characteristics of Carbonyl Compounds for Indoor Air in New Apartment (신축공동주택의 실내공기 중 카보닐화합물의 방출특성에 관한 연구)

  • Ryu, Jung-Min;Cho, Tae-Jin;Jang, Seong-Ki;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.807-818
    • /
    • 2010
  • The study is about variations in Carbonyl compounds concentration within apartment buildings according to pre-residence and residence. We consecutively investigated indoor air pollutants in 120 households in 6 cities at pre-residence and residence. Carbonyl compounds were collected using the 2,4-DNPH cartridge and were analyzed using HPLC. The carbonyls concentration of indoor air in the new apartments before occupation measured formadlehyde($76.0\;{\mu}g/m^3$), acetone($85.9\;{\mu}g/m^3$), acetaldehyde($13.8\;{\mu}g/m^3$). The carbonyls concentration of indoor air in the new apartments after occupation measured formadlehyde($233.1\;{\mu}g/m^3$), acetone($128.9\;{\mu}g/m^3$), acetaldehyde($29.8\;{\mu}g/m^3$), respectively. As a result, the mean concentration of carbonyl compounds within the pre-occupancy stage was lower than those of residence.

Childrens' Health Risk Assessment on Indoor Hazardous Air Pollutants of Preschool Facility (유아교육시설 내 실내공기유해오염물질에 대한 어린이 건강위해성평가)

  • Koh, Yeon-Jung;Kim, Shin-Do;Park, Suk-Young;Jang, Seong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.78-85
    • /
    • 2009
  • In this study, the hazard rate of the indoor environment of Children's Educational Facilities in Seoul was conducted, in order to determine how the indoor environments of these facilities, where infants and children spend the most time of their away from home day, can effect their health. The way of measurement and analysis were done according to the Indoor Air Quality Standard Method, and the Risk Assessment was accomplished with several significant ways - Hazard Identification, Exposure Assessment, Dose-response Assessment, Risk Characterization, which are deighed by National Research Council (NRC). On each exposure factors, documentary and questionary research such as Epidemiological study and Toxicological study were conducted. The result of the CTE (Central tendency exposure) of Formaldehyde and Benzene by Monte-Carlo simulation was $6.79{\times}10^{-6}$, $2.50{\times}10^{-7}$ which in the case of Formaldehyde exceeded the permitted standard ($10^{-6}$) of the US EPA. The RME(Reasonable maximum exposure) was $7.31{\times}10^{-5}$, $2.65{\times}10^{-6}$ which did not exceed $10^{-4}$, the maximum permitted standards in the US EPA.