• Title/Summary/Keyword: In-site evaluation method

Search Result 862, Processing Time 0.03 seconds

An Evaluation Method for Web Contents Services (웹콘텐츠 서비스 평가)

  • Jang, Hee S.;Park, Jong T.
    • Journal of Service Research and Studies
    • /
    • v.3 no.2
    • /
    • pp.33-44
    • /
    • 2013
  • As the Internet and mobile services increase, the use of wired/wireless web contents services increase and the demand for various contents explosively grows. To survive in competitive market, and to minimize the errors and warnings for web accessibility and standardization, and then to maximize the web usability, the periodical evaluation for web site should be performed with the events of web marketing and campaign. Through the web evaluation, the errors for technical programming language and contents offering can be found and diagnosed. In this paper, the quantitative and qualitative evaluation method for web site providing web contents are presented, and the analytic results for the 138 home pages in domestic are evaluated to validate the quantitative methodology. The accessibility, standardization, and usability factor are adopted for the evaluation in which accessibility is evaluated for perceivable, operable, understandable, and robust discipline with K-WAH(Korea-Web Accessibility Helper) tool, the standardization are measured for the number of errors and warnings in technical language with the W3C validator, and finally the usability factor is analyzed for the number of visits, average visit duration, and bounce rate with Google Analytics. In addition to, the quantitative analysis is also performed with the consideration of cost for construction and operation of web site. From the results, in the case of total score of 100 in conversion with relative weight, the average and standard deviation are evaluated to be 55 and 14, respectively. The correlation analysis indicates that the coefficient is estimated as 0.058, and then correlation between the quantitative results and cost is evaluated to be a little positive.

  • PDF

Evaluation of Near Subsurface 2D Vs Distribution Map using SPT-Uphole Tomography Method (SPT-업홀 토모그래피 기법을 이용한 지반의 2차원 전단파 속도 분포의 도출)

  • Bang, Eun-Seok;Kim, Jong-Tae;Kim, Dong-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.143-155
    • /
    • 2006
  • SPT-Uphole tomography method was introduced for the evaluation of near subsurface shear wave velocity (Vs) distribution map. In SPT-Uphole method, SPT (Standard Penetration Test) which is common in geotechnical site investigation was used as a source and several surface geophones in line were used as receivers. Vs distribution map which is the triangular shape around the boring point can be developed by tomography inversion. To obtain the exact travel time information of shear wave component, a procedure using the magnitude summation of vertical and horizontal components was used based on the evaluation of particle motion at the surface. It was verified that proposed method could give reliable Vs distribution map through the numerical study using the FEM (Finite Element Method) model. Finally, SPT-Uphole tomography method was performed at the weathered soil site where several boring data with SPT-N values are available, and the feasibility of proposed method was verified in the field.

A Study on the Evaluation of Semi-Anechoic Chamber Characteristics -mainly on horizontal polarization- (전파반무향실의 특성평가에 관한 연구 - 수평편파를 중심으로 -)

  • 김동일;김민석
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.1
    • /
    • pp.9-16
    • /
    • 1995
  • We are confronted with the serious EMI(electromagnetic interference) problems in company with the development of electronic equipments. Accordingly it is also required to construct some anechoic chambers for EMI measurement. Furthermore it is very important to evaluate the chamber characteristics in advance of its construction. For that purpose we have analyzed the characteristics by computer simulation in base on the image method, and compared the results with the measured ones. In case of 3-meter method as a result, the curved line of height pattern of open site varies similarly as that of height pattern of anechoic chamber. When we measure the electromagnetic strength and can get the height pattern curves by frequencies, we utilized it effectively because we can protect instrumental errors in measurement. On the other hand, there is a little difference in site attenuation above 700MHz. When the ferrite grid was used however, the calculated values agree well with the measured values up to 1000MHz with the exception of 30-40 MHz range. The reason is that we don't consider the antenna coupling in the low frequencies of 30-100MHz range.

  • PDF

A strength monitoring with wireless sensor network based on equivalent age method depending on the usage of the insulated formwork during the winter period (동절기 단열 유·무 거푸집을 설치한 슬래브 콘크리트에서 등가재령 기반의 무선센서 네트워크를 이용한 강도 모니터링)

  • Lee, Young-Jun;Lee, Hyuk-Ju;Hyeon, Seung-Yong;Seo, Hang-Goo;Lee, Sang-Woon;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.167-168
    • /
    • 2018
  • In this research, the feasibility of wireless senor for compressive strength evaluation was checked by applying on the actual apartment construction site with insulation formwork during winder period. As a result, there was no significant problem on monitoring the compressive strength of the concrete with the sensor. Thus it is considered that the suggested method can be an efficient method for the quality control at the construction site.

  • PDF

A Study on Cold-Weather Curing Quality Management Based on Using Energy Saving Electronic Heater (에너지 절감형 전기히터를 활용한 동절기 양생품질 관리방안)

  • Jo, Man-Ki;Hong, Sung-Min;Park, Jong-Hun;Kim, Jin-Sik;Lee, Dong-Hyun;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.109-110
    • /
    • 2020
  • In This study, we tried to review an efficient curing method in consideration of safety and constructability among the problems of winter construction. In other words, as a result of the mock-up test, the measured value of carbon monoxide was 0 ppm in the case of an electric hot air fan. Since there is no carbon monoxide, problems such as suffocation are expected to be solved. In terms of temperature characteristics, electric hot air fans exhibited high thermal efficiency performance with a slight difference in upper/lower temperatures compared to the existing ones. In the future, we plan to conduct thermal efficiency evaluation through actual site performance verification. We will propose an efficient curing method through applicability evaluation.

  • PDF

Multi-Dimensional Selection Method of Port Logistics Location Based on Entropy Weight Method

  • Ruiwei Guo
    • Journal of Information Processing Systems
    • /
    • v.19 no.4
    • /
    • pp.407-416
    • /
    • 2023
  • In order to effectively relieve the traffic pressure of the city, ensure the smooth flow of freight and promote the development of the logistics industry, the selection of appropriate port logistics location is the basis of giving full play to the port logistics function. In order to better realize the selection of port logistics, this paper adopts the entropy weight method to set up a multi-dimensional evaluation index, and constructs the evaluation model of port logistics location. Then through the actual case, from the environmental dimension and economic competition dimension to make choices and analysis. The results show that port d has the largest logistics competitiveness and the highest relative proximity among the three indicators of hinterland city economic activity, hinterland economic structure, and port operation capacity of different port logistics locations, which has absolute advantages. It is hoped that the research results can provide a reference for the multi-dimensional selection of port logistics site selections.

Stochastic ground-motion evaluation of the offshore Uljin Earthquake (울진앞바다 지진( '04. 5. 29, M=5.2)의 추계학적 지진동 평가)

  • Yun, Kwan-Hee;Park, Dong-Hee;Choi, Weon-Hack;Chang, Chun-Jung
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.18-25
    • /
    • 2005
  • Stochastic ground-motion method is adopted to simulate horizontal PGA values for the offshore Uljin earthquake recorded at nationwide seismic stations. For this purpose, the Fourier spectra are calculated at every stations based on comprehensive results of wave propagation and site effect which were previously revealed through inversion process applied to large accumulated spectral D/B. In addition, the apparent source spectrum of the offshore Uljin earthquake is estimated by removing the path and site response from the observed spectra. The distance dependent time-duration model is revised by iteratively fitting the PGA values generated by using the raw spectra data to the observed PGA data. The stochastic ground-motion method predicts the observed PGA values within a error of ${\sigma}_{log10}=0.1$. Transfer functions of a site relative to another site are estimated based on the error residual of the inversion results and used to convert PGA values at multiple stations to expected PGA values at a reference station of TJN. The converted PGA values can be used as basic data to evaluate the ground-motion attenuation relations developed for seismic hazard analysis that concerns the large damaging earthquakes.

  • PDF

Cost Effectiveness of Bse-Isolation for Bridges in Low and Moderate Seismic Region (중저진 지역에서의 지진격리교량의 경제적 효율성에 관한 연구)

  • 고현무
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.178-185
    • /
    • 1999
  • Minimum life-cycle cost helps to evaluate cost effectiveness of base-isolated bridges under specific condition. Life-cycle cost mainly consists of the initial construction cost and the expected damage cost. Damage cost estimation needs proper model of input ground motion failure probability evaluation method and limit states definition. We model the input ground motion as spectral density function compatible with the response spectra defined at each seismicity and site condition. Spectrum analysis and crossing theory is suitable for reseating calculation of failure probabilities in the process of cost minimization. Limit states of base-isolated bridges re defined for superstructure isolator and pier respectively The method is applied to both base-isolated bridges and conventional bridges under the same conditions to investigate cost effectiveness of base isolation in low and moderate seismic region. the results show that base-isolation of bridges are more effective in low and moderate seismic region and that the site effects on the economical efficiency may not be negligible in such a region.

  • PDF

Remediation of A DNAPL Contaminated Site Using Containment WALL (차단벽을 이용한 DNAPL 오염지역의 복구)

  • Lee, Kwang-Yeol;Joo, Wan-Ho
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.81-85
    • /
    • 1998
  • In the present study, the design method of containment walls is proposed by utilizing an existing site. The selected remedy for the Source Area of Operable Unit 2 at Hill Air Force Base stipulated containment of the pure-phase trichloroethylene contamination. The in-place-mixed wall construction was selected because of the irregular topography, small area of the site, and the requirement to reach depths of greater than 90 feet below ground surface. Bench-scale compatibility studies were performed for the containment wall mix design on three commercial bentonite clays. The samples were subject to screening tests and long-term tests for evaluation of changed soil properties when exposed to the contaminated groundwater.

  • PDF

A Study on the Reliability Evaluation of Start-up Power Supply in Fossil Power Plant by Minimal Cut-Set Method (최소 컷셋법에 의한 화력발전소 기동전원의 신뢰도 예측에 관한 연구)

  • Choe, Gyu-Sik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.358-364
    • /
    • 1999
  • The auxiliary transformers or start-up/stand-by transformer(s) are installed against the start-up and shut-down of generator and emergency status in fossil power plant. The on-site power supply configuration using these transformers must be determined, considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and ecfonomy of plant. The auxiliary or start-up/stand-by power supply configuration has been determined considering only safety requirements and construction cost until now in Korea. This paper presents general theorems for the reliability estimation and proposes 2-unit based 4 alternatives for the start-up power supply stystem of 500㎿ standardized fossil power plant. The reliability and unavailability of equipment, system and configuration are determined using minimal cut-set methodology. The optimized plan of 4 alternatives is determined based on this ultimate reliability and unavailability.

  • PDF