• 제목/요약/키워드: In-plane alignment

검색결과 174건 처리시간 0.028초

Ellipsometry에서의 Calibration 및 입사면 고정형 Ellipsometer (Calibration and a Plane of Incidence Fixed Ellipsometer)

  • 경재선;오혜근;안일신;김옥경
    • 반도체디스플레이기술학회지
    • /
    • 제2권4호
    • /
    • pp.23-26
    • /
    • 2003
  • The general users find difficulties in using ellipsometers. Thus, the object of this study is to construct an ellipsometer with simple operation principle. We developed an ellipsometer which does not require alignment and calibration before measuring sample. A basis structure model after rotating a compensator spectroscopic ellipsometry, the fixed incidence angle at $70^{\circ}$. This ellipsometer does not demand calibration, because the plane of incidence is not changed due to the novel sample holder structure. The results for various standard samples were compared with those from conventional RCSE to test the performance of this instrument. Also repeated measurements were performed to test the precision of the calibration coefficient in a plane of incidence fixed.

  • PDF

유기박막표면에 DuoPIGatron 이온소스를 이용한 IPS 셀의 전기광학 특성 (EO performance of IPS cell on the inorganic films surface using DuoPIGatron ion source)

  • 김병용;황정연;김상훈;한정민;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 학술대회 및 기술세미나 논문집 디스플레이 광소자
    • /
    • pp.89-90
    • /
    • 2006
  • Electro-optical (EO) characteristics of in-plane switching (IPS) cell on the polyimide surface using obliquely ion beam (IB) exposure as new ion beam (IB) type system (DuoPIGatrion ion source). A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the polyimide surface was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned IPS-cell on poly imide surface ; the stable VT curve in the ion-beam-aligned IPS cell on a poly imide (PI) surface with ion beam exposure using new type IB equipment was obtained. and the fast response time in the ion-beam-aligned IPS cell on a polyimide (PI) surface with ion beam exposure using new type IB equipment was obtained.

  • PDF

레이저 간섭계의 직각 평면거울에 대한 직각도 오차 측정 (Orthogonality Measurement of Square Plane Mirrors for Laser Interferometry)

  • 김태호;김승우
    • 한국정밀공학회지
    • /
    • 제15권12호
    • /
    • pp.169-179
    • /
    • 1998
  • Plane mirror type laser interferometers are popularly being used in many modern ultraprecision machines, as they can perform simultaneous measurements of multiple axis positions with nanometer resolution capabilities. One important issue in this application of laser interferometers is to provide a good level of alignment between the reflecting mirrors and the laser beams so that measurement errors due to undesirable coupling effects can be avoided in multiple axis measurements In this investigation, a thorough metrological analysis is given to develop an suitable mathematical model for a precision x-y stage in which the orthogonality misalignment between the reflecting mirrors significantly affects overall x-y mea-surement results. Then a noble calibration method is suggested in which two-dimensional displacement sensors of moire gratings of concentric circles are used to realize the reversal principle of orthogonality evaluation in situ. Finally, actual experimental results are discussed to verify that the suggested method can effectively calibrate the orthogonality error with an uncertainty of 0.2667 arcsec.

  • PDF

FeCoB Films with Large Saturation Magnetization and High Magnetic Anisotropy Field to Attain High Ferromagnetic Resonance Frequency

  • Nakagawa, Shigeki;Hirata, Ken-Ichiro
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.155-158
    • /
    • 2013
  • FeCoB films were being prepared on a Ru underlayer by using the oblique incidence of sputtered and back-scattered particles which have a high in-plane magnetic anisotropy field $H_k$ above 400 Oe. It is suitable to attain such deposition condition when facing targets sputtering system. The in-plane X-ray diffraction analysis clarified that there is anisotropic residual stress which is the origin of the high in-plane magnetic anisotropy. The directional crystalline alignment and inclination of crystallite growth were also observed. Such anisotropic crystalline structures may affect the anisotropic residual stress in the films. The B content of 5.6 at.% was appropriate to induce such anisotropic residual stress and $H_k$ of 410 Oe in this experiment. The film with B content of 6 at.% possessed large saturation magnetization of 22 kG and high $H_k$ of 500 Oe. The film exhibited high ferromagnetic resonance frequency of 9.2 GHz.

YBa$_2Cu_3O_x$ 후막의 단결정 MgO(001) 위에서의 배향화 (Texturing of YBa$_2Cu_3O_x$ thick film on MgO(001) single crystal)

  • 김유진;김명희;한영희;성태현;김상준;노광수
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.271-274
    • /
    • 1999
  • We are investigating epitaxially grown YBa$_2Cu_3O_x$(123) on MgO single crystal by partial melting process for high power application. After fabricating of BaCuO$_2$(011), Y$_2BaCuO_5$(211) powder, we made YBa$_2Cu_3O_x$(123) Paste with just mixing of (211), (011) and CuO(001) powders. Screen printing method was used to coat YBa$_2Cu_3O_x$(123) paste on MgO single crystal. To reduce the reaction in low temperature, rapid heating was conducted at partial melting temperature. The film was analysed with the difference of cooling-rate, thickness, reaction temperature by XRD, SEM, in-plane alignment, out-of-plane alignment, temperature-resistivity characteristics.

  • PDF

평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구 (Development of An Automated Scanning Laser Doppler Vibrometer For Measurements of In-Plane Structural Vibration)

  • 길현권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.422-430
    • /
    • 1996
  • The automated scanning laser Doppler vibrometer (LDV) has been designed, and built to measure in-plane displacements associated with waves propagating on vibrating structures. Use of optical fibers allows the compact design of a laser probe head which can be scanned over the vibrating structures. An algorithm for automated self-alignment of the laser probe is developed. The system is completely automated for scanning over the structures, focusing two laser beams at each data point until the detected vibration signal is stable, and for recording and transferring the data to a system computer. The automated system allows one to get extensive data of the vibration field over the structures. The system is tested by scanning a piezoelectric cylindrical shell and a plate excited by a continuous signal and by a pulse signal, respectively. Results show that the automated scanning LDV system can be a useful tool to measure the in-plane vibration field and to detect the elastic waves propagating on the vibrating structures.

  • PDF

Pose and Expression Invariant Alignment based Multi-View 3D Face Recognition

  • Ratyal, Naeem;Taj, Imtiaz;Bajwa, Usama;Sajid, Muhammad
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권10호
    • /
    • pp.4903-4929
    • /
    • 2018
  • In this study, a fully automatic pose and expression invariant 3D face alignment algorithm is proposed to handle frontal and profile face images which is based on a two pass course to fine alignment strategy. The first pass of the algorithm coarsely aligns the face images to an intrinsic coordinate system (ICS) through a single 3D rotation and the second pass aligns them at fine level using a minimum nose tip-scanner distance (MNSD) approach. For facial recognition, multi-view faces are synthesized to exploit real 3D information and test the efficacy of the proposed system. Due to optimal separating hyper plane (OSH), Support Vector Machine (SVM) is employed in multi-view face verification (FV) task. In addition, a multi stage unified classifier based face identification (FI) algorithm is employed which combines results from seven base classifiers, two parallel face recognition algorithms and an exponential rank combiner, all in a hierarchical manner. The performance figures of the proposed methodology are corroborated by extensive experiments performed on four benchmark datasets: GavabDB, Bosphorus, UMB-DB and FRGC v2.0. Results show mark improvement in alignment accuracy and recognition rates. Moreover, a computational complexity analysis has been carried out for the proposed algorithm which reveals its superiority in terms of computational efficiency as well.

대학생의 배가로근과 뭇갈래근 두께와 척추정렬간의 상관관계 (Correlations between the Muscle Thickness of the Transverse Abdominis and the Multifidus Muscle with Spinal Alignment in College Students)

  • 임재헌
    • PNF and Movement
    • /
    • 제12권4호
    • /
    • pp.243-248
    • /
    • 2014
  • Purpose: The transverse abdominis and themultifidus muscle are located in the core. They surround one's trunk and help in body stabilization. Specifically, they control spine articulation to maintain posture and balance. Therefore, weakened deep muscle in the trunk may cause spinal malalignment. This study aims to compare the correlation between the thickness of the transverse abdominis and the multifidus muscle and the spine alignment among college students in their 20s. Methods: This study measured the thickness of the transverse abdominis and the multifidus muscle of 42 healthy college students in their 20s using ultrasonic waves. The thickness of the muscle was measured for the length of the cross-section except for fascia. The thickness of the left and right muscles was measured, and the mean value was calculated. As the thickness of the transverse abdominis can increase because of pressure during exhalation, it was measured at the last moment of exhalation. Spinal alignment was measured by the kyphosis angle, lordosis angle, pelvic tilt, trunk inclination, lateral deviation, trunk imbalance, and surface rotation using Formetric III, which is a three-dimensional imaging equipment. They were measured for three times, and the mean values were calculated. The general characteristics of the subjects were analyzed using descriptive statistics. The correlations between each factor were analyzed using Pearson's correlation analysis. Results: The transverse abdominis showed asignificant correlation with trunk inclination (p<.05). The multifidus muscle showed a significant positive correlation with pelvic tilt and a negative correlation with surface rotation (p<.05). Conclusion: The thickness of transverse abdominis and the multifidus muscle appears to influence spinal alignment. Specifically, the multifidus muscle, which plays an important role on the sagittal plane, influences surface rotation, thus making it an important muscle for scoliosis patients. Therefore, a strengthening training program for the transverse abdominis and the multifidus muscle is necessary according to specific purposes among adults with spinal malalignment.

CeO2 완충층의 결정성장 특성 및 금속 유기물 증착법으로 제조된 초전도 YBCO층에 미치는 영향 (Texture Development of CeO2 Buffer Layer and its Effect on Superconducting MOD-YBCO Films)

  • 정국채;김영국
    • 대한금속재료학회지
    • /
    • 제47권10호
    • /
    • pp.681-685
    • /
    • 2009
  • $CeO_2$ buffer layers have been deposited on YSZ single crystal substrates via a radio-frequency sputtering method. We focused on the texture development of $CeO_2$ with out-of-plane alignment and its effects on a superconducting YBCO layer, which was deposited by metal organic deposition. $CeO_2$ layers were grown epitaxially on single crystal YSZ substrates and subsequent YBCO layers were also grown epitaxially from $CeO_2$ layers. It was observed that the intensity of $CeO_2$(200) decreased with deposition temperature. ${\theta}-2{\theta}$ scan FWHM values of $CeO_2$(200) were inversely proportional to the peak intensities of $CeO_2$(200). The sample with the lowest $CeO_2$(200) intensity and poor out-of-plane alignment showed a strong reaction with the MOD-YBCO layer resulting in a thicker $BaCeO_3$ layer. The texture and superconducting property of the YBCO layer were affected indirectly by the formation of a $BaCeO_3$ layer at the interface between the $CeO_2$ and YBCO layers.

Alignments of interacting haloes in the Horizon run 4 simulation

  • L'Huillier, Benjamin;Park, Changbom;Kim, Juhan
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.29.2-29.2
    • /
    • 2015
  • Interactions such as mergers and flybys play a fundamental role in shaping galaxy morphology. We used the Horizon Run 4 cosmological N-body simulations to study the aligments of spins and shapes of interacting haloes as a function of the halo mass and large-scale density. Interactions preferentially occur in the plane of rotation, and in the direction of the major axis of prolate haloes, and the trajectories are preferentially radial and prograde. We found a very strong alignment of the shapes already at redshift as high as 4. The spins are initially unaligned or even anti-aligned, and become more and more aligned as the redshift decreases. The alignment signals are stronger and evolve more at lower densities, and mass plays a secondary role.

  • PDF