• Title/Summary/Keyword: Impression Technique

Search Result 176, Processing Time 0.025 seconds

IN VIVO STUDY ON ABUTMENT TOOTH MOVEMENT FOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURES (유리단 국소의치의 지대치 운동에 관한 생체학적 연구)

  • Lee, Jong-Yeop;Kim, Kwang-Nam;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.43-61
    • /
    • 1990
  • The laser reflexion method is a new technique which permits precise contactless measurement and observation of tooth mobility as well as tooth movement. The purposes of this study were to clarify the reliability of the laser reflexion method in clinical application and to measure the abutment tooth movement according to clasp design. This study was designed to determine 1) How much a bending movement of the impression plate stand affects the position of the reflexion pattern and how precise the patient bites into plate 2) Which clasp design causes greater movement of the abutment tooth. Under medium and maximum bite forces, tests were performed on central loading position which was 13mm distal to terminal abutment tooth of distal extension removable partial denture. The movement in the mesiodistal and buccolingual directions was measured. The Duncan's New Multiple-Range test was used to compare the means for the four castings under each direction-load combination; and the paired sample t-test was for medium and maximum bite forces. From this experiment, the following results were obtained. 1. The Roach clasp, the combination clasp, the RPI clasp, and the Akers clasp did not significantly differ in their effects on buccolingual movement of the abutment tooth. 2. The direction of abutment tooth movement was not significantly altered by clasp design and all abutment tooth movements were oriented distobuccally. 3. Under medium bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the combination clasp and the RPI clasp. Under maximum bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the RPI clasp. 4. The testing apparatus and procedures used in this study(laser reflexion method) proved to be reliable in clinical application.

  • PDF

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.

Fitness of heat - pressed ceramic laminate veneer using additive manufacturing process: 3 Dimensional analysis (적층가공방식을 이용한 열가압 세라믹 라미네이트 비니어의 적합도: 3차원 분석)

  • Kang, Seen-Young;Lee, Ha-Na;Kim, Eo-Bin;Lee, Kyung-Eun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.39 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • Purpose: The purpose of this study is to analyze the fitness of heat - pressed ceramic laminate veneers fabricated using the additive manufacturing. Methods: Impression was replicated by using light body silicone and heavy body silicone on the custom tray, and it was fabricated using Type IV Stone. The test specimens were prepared by using a dental scanner, a laminating veneer using a dental design program, and a specimen with a 3D printer. The control specimens were prepared by the lost wax technique and heat - pressed to fabricate the specimens. The data of the specimens were measured by the RMS value of the internal fitness a using a 3-dimensional measurement program. Results: The Stereolithography laminate veneer group was measured at $78.10(4.09){\mu}m$ and the LWV group was measured at $31.50(5.10){\mu}m$. There is a significant difference between the two groups (p<0.001) Conclusion : Evaluation of fitness laminate veneers was fabricated by additive manufacturing showed the difference statistically significantly and clinically acceptable result.

A Study on the Orientalism Expressed in the Fashion of 1990's (1990년대 패션에 나타난 오리엔탈리즘에 관한연구)

  • 은영자
    • Journal of the Korean Society of Costume
    • /
    • v.43
    • /
    • pp.259-282
    • /
    • 1999
  • To analyze the characteristics of Orientalism which is expressed in the fashion of the 1990's this study was examined according to three aspects such as form textiles and pattern and the aspects was considered with regard to Chinese Indian Japanese Korean, Southeas Asian and North African style. 1. In form Orientalism which is influenced by latest other fashion trend; Naturalism and Minimalism is expressed as a comfortable casual style which simplifies the way of wearing and mixes the characteristic elements of folk costume with western costume. The way of layerd wearing like knotting wrapping draping and the symbolic from which is inspired by the unique are of each country are shown. 2. In textiles Chinese Japanese and Indian silk as well as Southeast Asian and North African cotton show a splendid oriental impression using vivid color. On the other hand the linens of Korea like hemp and ramie emphasize natural characteristics and show a simple and unartificial oriental beauty. But in the use of material and color it shows a remarkable tendency to break the preconceived idea by coordinating a luxurious silk with a practical denim or harmonizing technical new-masterials with traditional materials. 3. In pattern the decorative elements of Orientalism such as a traditional pattern skills to dye embroidery and other decorations are emphasized on the form of western costume. The sketchy patterns of Chinese Korean and Japanese styles which include the pattern of a flower a bamboo and a butterfly are expressed using embroidery or textile printing. The geometrical seriate patterns of Southeast Asian and North African styles use traditional dyeing methods like Batik. Also the Indian technique of decoration like Mirro Work satisfies handcrafted royalty and feminine romantic taste in modern minimal fashion. The Orientalism expressed in the fashion of 1990's emphasizes the characteristics of people wearing colthing which break the preconceived idea by simplifying the form harmonizing differences between oriental and western cultures and mixing the elements of traditional costumes among countries. Most of all. Ethno using geonmetrical seriate pattern and technical new metal material and Romantic Ethnic using flower embroidery precious stones and beads are appearing as a distinctinve feature.

  • PDF

Digital approach for fabrication of zirconia restoration with optimal gingival adaptation after tooth extraction: A case report (발치 후 지르코니아 보철물 제작에서 최적의 연조직 적합 형성을 위한 디지털 치료 증례)

  • Mai, Hang Nga;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.217-220
    • /
    • 2020
  • Conventionally, when a zirconia fixed dental restoration is planned, the interim restoration is made manually and the final restoration is fabricated by the silicone impression taking at the prosthodontic stage. This conventional workflow does not provide direct relation between interim and final restorations. Moreover, the predictability of the final restoration could be low. Nowadays, the CAD/CAM based restoration fabrication and related digital techniques are developed and being applied in dentistry in multiple ways. This case report introduces a digital workflow for fabricating an optimal gingival adaptation and predictability of monolithic zirconia restoration by using CAD/CAM interim restoration, intra oral scan, and image superimposition technique in a case that required tooth extraction.

A Study on Environment Design of Water-Front using Media Art of Fractal Image (프랙탈 이미지의 미디어아트를 활용한 Water-Front 환경디자인에 관한 연구)

  • Joo, Haejeong;Kim, Jong-il;Kim, Jong-chan;Kim, Cheeyong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.108-111
    • /
    • 2009
  • By a development of high-advanced science technology, the area of image made inter-area's communication more actively. Such the inter-image exchange facilitated a new combination of areas. By such the development and the activation of public design, the area of image has been extended into the area of environmental design as the public meaning. According to this flow, the media art of using a light has been introduced in the environment of water-front in Korea. Hence, it enhanced the region's identity and gave a special impression to tourists. However, the study on the area of image in the Korean environment aldesign is still in sufficient. Accordingly, the constant expression development absolutely required. For develop ingand researching a variety of expression techniques, the utilization of media art is expected to work as the alternative of image expression technique.

  • PDF

Rehabilitation of fully edentulous patient using Ceramill full denture system (FDS) (Ceramill full denture system을 이용한 무치악 환자의 양악 총의치 제작)

  • Lee, Younghoo;Kwon, Kung-Rock;Pae, Ahran;Noh, Kwantae;Paek, Janghyun;Hong, Seoung-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.232-237
    • /
    • 2019
  • CAD/CAM technology has already been used in most areas of prosthetics. The range of CAD/CAM application in denture fabricating process has been gradually increasing since the CAD/CAM technology was introduced for the fabrication of complete dentures in 1994. This paper describes a technique that combines conventional and CAD/CAM technology for the fabrication of complete dentures: the master casts from a conventional impression techniques were scanned first, and the wax denture was fabricated using Amann Girrbach's Ceramill full denture system (fds). The purpose of this paper is to introduce the case in which making an esthetically and functionally satisfied denture in shorter time is possible with CAD/CAM technology.

A Study of the Ornamental Metal used in the Eaves of Ancient Architecture in Korea (고대 건축의 처마에 사용된 금속장식에 관한 연구)

  • Youn, Lily
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.5
    • /
    • pp.117-124
    • /
    • 2020
  • This study examined ornamental metals used as architectural members among metal artifacts excavated from ancient Buddhist temples and palaces in Korea. Through this, we approached the decorative characteristics of ancient architecture eaves. 1. The decorations used in eaves of Korean ancient architecture include roof-end tiles and ornamental metal. Through excavation examples, the technique of attaching ornamental metal to the rafters and corner rafters of high-ranking architectures in the 7th and 8th centuries (ornamental metal for rafter end, ornamental metal for corner rafter end), and tosu iron in the 10th century It seems to be fashionable. 2. Several buildings were built in ancient Buddhist temples and palaces. At this time, they differentiated ornamental metal according to the hierarchy of the building. The higher the hierarchy, the greater the difference in the number of ornamental metal installations, materials, and decoration techniques. In addition, ornamental metal used in eaves is an important factor in the discrimination of the times as the type, number of members, and patterns change depending on the era. 3. The great feature of the eaves metal decoration excavated in the 7th and 8th centuries is the attachment of ornamental metal to the rafters and horsetails. This seems to create a sense of grandeur by removing the weight of the roof and giving the impression constructed regardless of gravity by supporting it with non-material materials.

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon;Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.176-181
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.