Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University) ;
  • Kim, Chong-Myeong (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University) ;
  • Kim, Ji-Hwan (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University) ;
  • Kim, Hae-Young (Department of Dental Laboratory Science and Engineering, College of Health Science & Department of Public Health Sciences, Graduate School & BK21+ Program in Public Health Sciences, Korea University) ;
  • Kim, Woong-Chul (Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University)
  • Received : 2016.08.12
  • Accepted : 2017.01.10
  • Published : 2017.06.30

Abstract

PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.

Keywords

References

  1. Konstantoulakis E, Nakajima H, Woody RD, Miller AW. Marginal fit and surface roughness of crowns made with an accelerated casting technique. J Prosthet Dent 1998;80:337-45. https://doi.org/10.1016/S0022-3913(98)70135-0
  2. Tao J, Yoda M, Kimura K, Okuno O. Fit of metal ceramic crowns cast in Au-1.6 wt% Ti alloy for different abutment finish line curvature. Dent Mater 2006;22:397-404. https://doi.org/10.1016/j.dental.2005.04.025
  3. Ucar Y, Akova T, Akyil MS, Brantley WA. Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns. J Prosthet Dent 2009; 102:253-9. https://doi.org/10.1016/S0022-3913(09)60165-7
  4. Duret F, Blouin JL, Duret B. CAD-CAM in dentistry. J Am Dent Assoc 1988;117:715-20. https://doi.org/10.14219/jada.archive.1988.0096
  5. Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J 2009;28:44-56. https://doi.org/10.4012/dmj.28.44
  6. Davis DR. Limiting wax pattern distortion caused by setting expansion. J Prosthet Dent 1987;58:229-34. https://doi.org/10.1016/0022-3913(87)90182-X
  7. van Noort R. The future of dental devices is digital. Dent Mater 2012;28:3-12. https://doi.org/10.1016/j.dental.2011.10.014
  8. Kim CM, Kim SR, Kim JH, Kim HY, Kim WC. Trueness of milled prostheses according to number of ball-end mill burs. J Prosthet Dent 2016;115:624-9. https://doi.org/10.1016/j.prosdent.2015.10.014
  9. Ortorp A, Jonsson D, Mouhsen A, Vult von Steyern P. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. Dent Mater 2011;27:356-63. https://doi.org/10.1016/j.dental.2010.11.015
  10. Huang SH, Liu P, Mokasdar A, Hou L. Additive manufacturing and its societal impact: a literature review. Int J Adv Manuf Technol 2013;67:1191-203. https://doi.org/10.1007/s00170-012-4558-5
  11. Park JY, Kim HY, Kim JH, Kim JH, Kim WC. Comparison of prosthetic models produced by traditional and additive manufacturing methods. J Adv Prosthodont 2015;7:294-302. https://doi.org/10.4047/jap.2015.7.4.294
  12. Lee IH, Cho DW. Micro-stereolithography photopolymer solidification patterns for various laser beam exposure conditions. Int J Adv Manuf Technol 2003;22:410-6. https://doi.org/10.1007/s00170-003-1538-9
  13. Akova T, Ucar Y, Tukay A, Balkaya MC, Brantley WA. Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain. Dent Mater 2008;24: 1400-4. https://doi.org/10.1016/j.dental.2008.03.001
  14. Kim KB, Kim WC, Kim HY, Kim JH. An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system. Dent Mater 2013;29:e91-6.
  15. Furst A, Radding SB. New developments in the study of metal carcinogenesis. J Environ Sci Health Part C 1984;2:103-33.
  16. Lu Y, Chen W, Ke W, Wu S. Nickel-based (Ni-Cr and Ni-Cr-Be) alloys used in dental restorations may be a potential cause for immune-mediated hypersensitivity. Med Hypotheses 2009;73:716-7. https://doi.org/10.1016/j.mehy.2009.04.041
  17. Reclaru L, Unger RE, Kirkpatrick CJ, Susz C, Eschler PY, Zuercher MH, Antoniac I, Luthy H. Ni-Cr based dental alloys; Ni release, corrosion and biological evaluation. Mater Sci Eng C Mater Biol Appl 2012;32:1452-60. https://doi.org/10.1016/j.msec.2012.04.025
  18. Pradies G, Zarauz C, Valverde A, Ferreiroa A, Martinez-Rus F. Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent 2015;43:201-8. https://doi.org/10.1016/j.jdent.2014.12.007
  19. Aktas G, Ozcan N, Aydin DH, Sahin E, Akca K. Effect of digitizing techniques on the fit of implant-retained crowns with different antirotational abutment features. J Prosthet Dent 2014;111:367-72. https://doi.org/10.1016/j.prosdent.2013.11.001
  20. Chazine M, Casucci A, Mazzoni A, Grandini S, Goracci C, Breschi L, Ferrari M. Interfacial nanoleakage and internal cement thickness of three esthetic crown systems. Dent Mater 2012;28:1105-11. https://doi.org/10.1016/j.dental.2012.07.005
  21. Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J. Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 2009;25:94-102. https://doi.org/10.1016/j.dental.2008.04.018
  22. Karlsson S. The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 1993;51:129-34. https://doi.org/10.3109/00016359309041158
  23. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131: 107-11. https://doi.org/10.1038/sj.bdj.4802708
  24. Fransson B, Oilo G, Gjeitanger R. The fit of metal-ceramic crowns, a clinical study. Dent Mater 1985;1:197-9. https://doi.org/10.1016/S0109-5641(85)80019-1
  25. Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 2010;38:553-9. https://doi.org/10.1016/j.jdent.2010.03.015
  26. Boening KW, Walter MH, Reppel PD. Non-cast titanium restorations in fixed prosthodontics. J Oral Rehabil 1992;19:281-7. https://doi.org/10.1111/j.1365-2842.1992.tb01103.x
  27. Jacobs MS, Windeler AS. An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 1991;65:436-42. https://doi.org/10.1016/0022-3913(91)90239-S
  28. Kokubo Y, Tsumita M, Kano T, Sakurai S, Fukushima S. Clinical marginal and internal gaps of zirconia all-ceramic crowns. J Prosthodont Res 2011;55:40-3. https://doi.org/10.1016/j.jpor.2010.09.001
  29. Elshahawy W. Marginal accuracy in casting titanium fixed partial dentures. Tanta Dent J 2015;12:119-23. https://doi.org/10.1016/j.tdj.2015.03.002
  30. Singh V, Gupta S, Bhargava A, Kaul S. Marginal accuracy of metal copings produced with different ring casting techniques: An in vitro study. Eur J Prosthodont 2015;3:36-41. https://doi.org/10.4103/2347-4610.157824
  31. Molin M, Karlsson S. The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study. Acta Odontol Scand 1993;51:201-6. https://doi.org/10.3109/00016359309040568
  32. Grenade C, Mainjot A, Vanheusden A. Fit of single tooth zirconia copings: comparison between various manufacturing processes. J Prosthet Dent 2011;105:249-55. https://doi.org/10.1016/S0022-3913(11)60040-1
  33. de Torres EM, Rodrigues RC, de Mattos Mda G, Ribeiro RF. The effect of commercially pure titanium and alternative dental alloys on the marginal fit of one-piece cast implant frameworks. J Dent 2007;35:800-5. https://doi.org/10.1016/j.jdent.2007.07.013
  34. Hutton JE, Marshall GW. The expansion of phosphate bonded investments: Part I-Setting expansion. J Prosthet Dent 1993;70:121-5. https://doi.org/10.1016/0022-3913(93)90005-9