• Title/Summary/Keyword: Implant placement

Search Result 644, Processing Time 0.025 seconds

Clinical, histologic, and histometric evaluation of implants with microthreaded crest module and SLA surface (SLA로 표면처리한 microthreaded crest module 임프란트의 임상적, 조직학적, 조직계측학적 분석)

  • Moon, Sang-Kwon;Pang, Eun-Kyoung;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.127-138
    • /
    • 2004
  • Background: Crestal bone loss known as saucerization is a frequently observed phenomenon. Recent studies have shown that implants with micothreaded crest module reduced the force concentration in the crestal region thus resulting in no or reduced crestal bone loss. This study presents a clinical, histologic, and histometric evaluation of implants with microthreaded crest module and SLA surface. Methods: The implants were placed in the mandible of 5 beagle dogs weighing 10-15kg. Four premolars were bilaterally extracted 8 weeks prior to implant placement. Mucoperiosteal flap was elevated and drilling with increasing diameter was performed under saline irrigation. After countersinking 2 implants were placed in each side resulting in 4 implants per dog. Healing period of 8 weeks was allowed before sacrificing the animals. Histologic preparation was performed for histologic and histometric analysis. Bone to implant contact as well as percentage of bone area inside threads were measured. T-test was used for statistical analysis with pvalue p<0.05. Results: 1. Healing was uneventful without any cover screw exposure. New bone formation around the implants was observed without any inflammatory infiltration. 2. Bone to implant contact in the microthread and thread were 43.90 ${\pm}$ 20.30 %, and 53.19 ${\pm}$ 20.97 % respectively. The overall bone to implant contact was 48.54 ${\pm}$ 20.95 %. 3. Percentage of bone area inside threads were 54.43 ${\pm}$ 10.39 %, and 38.44 ${\pm}$ 16.44 % for the microthread and thread respectively. There was statistically significant difference(p<0.05). The overall percentage of bone area inside threads was 46.67 ${\pm}$ 15.68 %.

Implant assisted removable partial denture using a few remaining maxillary teeth and locator bar system: A case report (소수 잔존치를 가진 상악에 Bar와 Locator®를 이용한 임플란트 융합 국소의치 치료 증례)

  • Kim, Seong-Jung;Bae, Eun-Bin;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of the Korean dental association
    • /
    • v.55 no.8
    • /
    • pp.528-536
    • /
    • 2017
  • Treatment with removable partial denture is effective for partially edentulous patients who are unable to obtain sufficient retention and stability for functional and esthetic restoration. There are several cases reporting the improvement of retention and stability of the partial denture using a small number of implants. However, there are limited studies on the implant-assisted removable partial denture using a small number of remaining teeth and the bar locator system. The bar locator system has an advantage in that it could compensate the angle of insertion of removable prosthesis on implant with inconsistent placement angle due to anatomical constraints compared to when using the locator only. This case report describes the patient with $Parkinson^{\circ}$Øs disease who was treated with the Locator bar system using two previously placed implants and two remaining teeth on maxilla. No additional implants could be placed because of the medical and economic condition of the patients, and the angle of one of two implants could not be matched with the direction of the removable partial denture insertion. Considering the angle of the implants, the patient was treated with implant-assisted RPD using the Locator bar system and had satisfactory results in the aspect of esthetics, masticatory function, and oral hygiene maintenance.

  • PDF

A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS (표면처리가 다른 5종 임플랜트의 안정성에 관한 연구)

  • Kim Sun-Jong;Shin Sang-Wan;Jung Sung-Min;Ryu Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.

Finite Element Stress Analysis of Bone Tissue According to the Implant Connection Type (2종의 임플란트 내부결합구조체에 따른 치조골상 유한요소응력 분석)

  • Byun, Ook;Jung, Da-Un;Han, In-Hae;Kim, Seong-Ryang;Lee, Chang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.259-271
    • /
    • 2013
  • The purpose of this study was to make the stress distribution produced by simulated different load under two types of internal connection implant system (stepped and tapered type) by means of 3D finite element analysis, The finite element model was designed with the parallel placement of the one fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st molar. Two models were loaded with 200 N magnitude in the vertical direction on the central position of the crown, the 1.5 mm and 3 mm buccal offset point from the central position of the fixture. The oblique load was applied at the angle of $30^{\circ}$ on the crown surface. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual dimension. The results were as follows; 1. The loading conditions of two internal connection implant systems (stepped and tapered type) were the main factor affecting the equivalent bone strain, followed by the type of internal connections. 2. The stepped model had more mechanical stability with the reduced max. stress compared to $11^{\circ}$ tapered models under the distributed oblique loading. 3. The more the contact of implant-abutment interface to the inner wall of implant fixture, the less stress concentration was reduced.

The effect of various thread designs on the initial stability of taper implants

  • Park, Ju-Hee;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • STATEMENT OF PROBLEM. Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc. PURPOSE. The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone(Group 1) and the rest of which were not engaged to inferior cortical wall(Group 2) by measuring the implant stability quotient(ISQ) and the removal torque value(RTV). MATERIAL AND METHODS. In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer s recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell $mentor^{(R)}$ and with removal torque using MGT50 torque gauge. RESULTS. In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants(P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not(P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2(P < .05). CONCLUSIONS. Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.

An 8-year survival rate of immediate implants: retrospective study (발치후 즉시 임플란트의 8년 누적 생존율에 대한 후향적 연구)

  • Ko, Seung-Hee;Chang, Yun-Young;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • The Journal of the Korean dental association
    • /
    • v.47 no.11
    • /
    • pp.758-768
    • /
    • 2009
  • Purpose : Schulte introduced immediate implant cases in 1970s, since then many patients have been treated by immediate implants. The aim of this study was to evaluate the cumulative survival rate of immediate implant and to analyze various factors associated with survival of immediate implant in a 8-year period retrospectively. Materials and methods : From May, 2000 to October, 2007, 77 implants were placed in 63 patients immediately after tooth extraction at Department of Periodontology, Yonsei University Hospital. The implant survival rate was analyzed using a life-table analysis. After delivery of prosthesis, along 1 year of observation period, all implants were evaluated clinically and radiographically. Results : Among 77 implants, 59 were placed in maxilla and 18 in mandible. The most common site of the implantation was Mx anterior (65%). The overall survival rate was 94.8% over a mean follow-up period of $44.2{\pm}21$ months and the 8-year cumulative survival rate was 94.6%. Failure occurred in 4 implants, all of which were due to early failures. None of the following factors were significantly associated with the survival of immediate implants: advanced surgical technique including bone graft and guided bone regeneration, the types of implants, causes of tooth loss, and types of prosthesis. Conclusion : On the basis of 8-year life time analysis, immediate implant placement can be considered a safe and predictable treatment mordality.

  • PDF

Radiologic evaluation and survival rate of taper-straight designed implant with SLA surface: A 1-year follow-up retrospective study (SLA surface를 가진 taper straight designed implant의 방사선학적 평가와 생존율: 1년 추적 관찰을 통한 후향적 연구)

  • Kim, Jee Eun;Kim, Ye Seul;Kim, Ok-Su
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.405-414
    • /
    • 2021
  • Purpose. This study was conducted to evaluate clinical usefulness by evaluating the marginal bone resorption and survival rate of an implant with a taper straight type SLA surface domestically available on the market recently. Materials and methods. 40 implants satisfying the including criteria were observed for one year of 125 implants of 83 adult men and women who had KISPLANT® implanted from August 2016 to December 2019 at the Department of Periodontology, Chonnam National University Dental Hospital. The marginal bone level was measured on periapical radiographs taken initially and 1 year later and we analyzed implant survival and success rates. A t-test was used for the analysis of the association between the marginal bone resorption and the severity of periodontitis, supportive periodontal therapy, the inserted site, the cause of extraction, immediate placement, and systemic disease. Results. After 1 year of loading, the mesial bone resorption was 0.74 ± 1.07 mm, and the distal bone resorption was 0.53 ± 1.04 mm. The marginal bone resorption of 2 mm or more occurred at 3 implants out of 40 implants after 1 year, so the success rate of implant was 92.5% and survival rate was 100%. There was a significant difference in mesial marginal bone resorption according to the inserted site and no significant differences were found between marginal bone resorption and the other factors. Conclusion. As a result of marginal bone resorption, success rate, and survival rate in this study, we found little marginal bone resorption and high survival and success rate. It can be concluded that they represent excellent clinical results.

The effects of hard and soft tissue grafting and individualization of healing abutments at immediate implants: an experimental study in dogs

  • Thoma, Daniel S.;Jung, Ui-Won;Gil, Alfonso;Kim, Myong Ji;Paeng, Kyeong-Won;Jung, Ronald E.;Fickl, Stefan
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.3
    • /
    • pp.171-184
    • /
    • 2019
  • Purpose: To evaluate the effects of intra-alveolar socket grafting, subepithelial connective tissue grafts, and individualized abutments on peri-implant hard and soft tissue outcomes following immediate implant placement. Methods: This randomized experimental study employed 5 mongrel dogs, with 4 sites per dog (total of 20 sites). The mesial roots of P3 and P4 were extracted in each hemimandible and immediate dental implants were placed. Each site was randomly assigned to 1 of 4 different treatment groups: standardized healing abutment (control group), alloplastic bone substitute material (BSS) + standardized healing abutment (SA group), BSS + individualized healing abutment (IA group), and BSS + individualized healing abutment + a subepithelial connective tissue graft (IAG group). Clinical, histological, and profilometric analyses were performed. The intergroup differences were calculated using the Bonferroni test, setting statistical significance at P<0.05. Results: Clinically, the control and SA groups demonstrated a coronal shift in the buccal height of the mucosa ($0.88{\pm}0.48mm$ and $0.37{\pm}1.1mm$, respectively). The IA and IAG groups exhibited an apical shift of the mucosa ($-0.7{\pm}1.15mm$ and $-1.1{\pm}0.96mm$, respectively). Histologically, the SA and control groups demonstrated marginal mucosa heights of $4.1{\pm}0.28mm$ and $4.0{\pm}0.53mm$ relative to the implant shoulder, respectively. The IA and IAG groups, in contrast, only showed a height of 2.6mm. In addition, the height of the mucosa in relation to the most coronal buccal bone crest or bone substitute particles was not significantly different among the groups. Volumetrically, the IA group ($-0.73{\pm}0.46mm$) lost less volume on the buccal side than the control ($-0.93{\pm}0.44mm$), SA ($-0.97{\pm}0.73mm$), and IAG ($-0.88{\pm}0.45mm$) groups. Conclusions: The control group demonstrated the most favorable change of height of the margo mucosae and the largest dimensions of the peri-implant soft tissues. However, the addition of a bone substitute material and an individualized healing abutment resulted in slightly better preservation of the peri-implant soft tissue contour.

Aesthetic implant restoration with alveolar bone graft and digital method on maxillary central incisor: a case report (치조골이식과 디지털 방법을 활용한 상악 중절치 임플란트 심미 수복 증례)

  • Jang, Han-Sol;Pyo, Se-Wook;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.168-174
    • /
    • 2022
  • In case of gingival recession or bone defect in maxillary anterior implant treatment, it is not easy to obtain satisfactory clinical results. In this case, loss of the labial alveolar plate was diagnosed in the maxillary right central incisor, so after tooth extraction, soft tissue was secured and implant placement with bone graft was planned. In addition, digital guide surgery was performed for the ideal implant position, and GBR (Guided Bone Regeneration) was accompanied with the xenogeneic bone and the autologous bone collected from the mandibular ramus since alveolar bone defects were extensive. After a sufficient period of osseointegration of the implant, a temporary prosthesis was fabricated through secondary stage surgery and impression taking, and through periodic external adjustment, the shape of soft tissue was improved. In the final prosthesis fabrication, a color tone of natural teeth was induced by an gold anodized customized abutment, and an aesthetic and functional zirconia prosthesis with reproducing the shape of the temporary prosthesis through intraoral scan was delivered.

Success rate and marginal bone loss of Osstem USII plus implants; Short term clinical study (Osstem USII plus 임플란트의 단기간 성공률 및 변연골 흡수량 평가)

  • Kim, Sun-Keun;Kim, Jee-Hwan;Lee, Keun-Woo;Cho, Kyoo-Sung;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the clinical value of Osstem$^{(R)}$ USII plus system implants. Clinical and radiographic data were analyzed for 88 implants placed and functionally loaded for a 12 month period at the Yonsei University Dental Hospital. Materials and Method: Based on the patient's medical records, clinical factors and their effects on implant marginal bone resorption, distribution and survival rate were analyzed. The marginal bone loss was evaluated at implant placement and during a 6 to 12 months functional loading period. The independent sample t-test was used to evaluate the interrelationship between the factors (${\alpha}$=0.05), and one way repeated measures ANOVA was used to compare the amount of marginal bone resorption. Results: The cumulative survival rate for 88 implants was 100%. The marginal bone resorption from implant placement to prosthetic delivery was 0.24 mm and the average marginal bone resorption from prosthetic delivery to 12 months of functional loading was 0.19 mm. The total average bone resorption from implant placement to 12 months of functional loading was 0.43 mm. There were no statistically differences in the amount of marginal bone resorption when implants were placed in the maxilla or the mandible (P>.05), however, implants placed in the posterior areas showed significantly more marginal bone loss than those placed in the anterior areas (P<.05). Conclusion: Based on these results, the short term clinical success rate of RBM surface treated external connection domestic implants showed satisfactory results and the marginal bone loss was in accord with the success criteria of dental implants.