• Title/Summary/Keyword: Impact measurement

Search Result 1,328, Processing Time 0.023 seconds

Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source (표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가)

  • Yong-Bong Lee;Hyok-Je Kwon;Chang-Whan Kim;Man-Hee Cho;Hang Kim;SungSoo Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • In this paper, a method for evaluating the measurement uncertainty is proposed when measuring of floor impact sound insulation of buildings using standard heavy impact source. In addition to the effect of repeated measurements, several other factors such as measurement location, impact location, equipment used for sound pressure measurement, and heavy impact source, were considered. A mathematical model for the average maximum impact sound level and the uncertainty evaluation method for each factor were proposed. The present proposed method was applied to measurement results to evaluate the average maximum impact sound pressure level and the measurement uncertainty.

Floor Impact Noise Measurement and Evaluation Method Using Impact Ball (임팩트 볼을 활용한 바닥충격음 측정 및 평가)

  • Jeon, Jin-Yong;Jeong, Jeong-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.10 s.103
    • /
    • pp.1160-1168
    • /
    • 2005
  • Floor impact noise isolation performance of reinforced concrete floors was investigated through new measurement method using impact bail. Strong impact force in Bow frequency band below 63 Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight Impact noise but heavy-weight impact noise measurement and evaluation using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

A Study on Estimation of Uncertainty in Measurement of Light Impact Sound Insulation of Floors (공동주택 경량바닥충격음 측정불확도 추정에 관한 연구)

  • Go, Jong-Chul;Lee, Jong-In;Kim, Hyun-Bae;Lee, Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1409-1416
    • /
    • 2006
  • In measuring, uncertainty in measurement is essential to improve measuring reliability. Currently, however, in measuring impact sound insulation of floors, there are no guidelines to estimate uncertainty in measurement. In addition, the concept of uncertainty in rating is required to recognize the relation between measuring and rating. Therefore, through this paper, the efforts have been made to establish uncertainty in measurement and rating of light impact insulation of floors. The result of estimating of uncertainty in measurement and rating in our laboratory is considered reliable, considering ${\pm}0.46{\sim}1.44dB$ of uncertainty in measurement and 1 dB of uncertainty in rating.

  • PDF

Measurement uncertainty in heavy-weight floor impact sounds (측정 불확도에 따른 중량충격음 측정편차에 관한 연구)

  • Yoo, Seung-Yup;Kim, Yong-Hee;Sim, Myoung-Hee;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.826-829
    • /
    • 2008
  • In a field measurement, measurement errors are produced by measuring environments and systematic errors in the measurement procedure. Measurement errors can be expressed as a measurement uncertainty. In this study, the measurement uncertainty and various measuring factors are investigated in heavy-weight impact sounds. According to KS 2810-2, the model functions, which is the estimation of the maximum SPL measurement in each octave band frequency, are determined. From this estimation model, 3.53dB is shown in 63Hz. This level is caused by the sound field of the receiving room, which does not meet the diffusing field.

  • PDF

Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance (바닥충격음 측정 및 차음 평가의 방향)

  • Jeong, Jeong-Ho;Jeong, Yeong;Seo, Sang-Ho;Song, Hee-Soo;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

Review of measurement of impact sound improvement for light-weight floor (경량 바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰)

  • Jang, Gil-Soo;Jung, Kwang-Yong;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.950-955
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

Review of measurement of impact sound improvement for light-weight floor (경량바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰)

  • Jang, Gil-Soo;Kim, Sun-Woo;Jung, Kwang-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.392.2-392
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the Physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

A study on the impact prediction in environmental impact statement (환경영향평가서 영향예측에 대한 연구)

  • 이영경
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.25 no.3
    • /
    • pp.89-100
    • /
    • 1997
  • The purpose of this paper was to analyze the content of impact prediction in EISS, in order to find the degree of the acuracy of impact prediction . 30 EISS were selected as analysis objects through variance miximization strategy. Content analysis of the selected EISS was performed by 5 analysis items, such as quantification of measurement, range of impact area, time frame of impact, likelihood of impact, and explict characterization of impact significance. The results showed that the accuracy investigated by the 5 items was very low. In conclusion, 5 suggestions were proposed in order to improve the credibility of EIS as a scientific report. The 5 suggestions were : 1) impact prediction should be described by quantitative measurement; 2) In establishing the time frame of the impact and the referent populatioin influenced by the impact, the characteristics of the proposed action should be carefully considerd; 3) the significance of the predicted impact should be quantitatively described; 4) specific description should also be used in the likelihood or the probability of the predicted impact in a real world; 5) equal emphasis should be put on the three environment, including natural and social as well as living environment.

  • PDF

Setting the Current Air Quality Concentration Using the National Atmosphere Measurement Network

  • CHO, Dong-Myung;LEE, Ju-Yeon;KWON, Lee-Seung;KIM, Su-Hye;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.3
    • /
    • pp.23-33
    • /
    • 2021
  • Purpose: In the course of the domestic environmental impact assessment, the current status survey was improperly conducted, and the issue of false and inaccurate environmental impact assessment reports has been raised several times recently through media reports. Research design, data and methodology: There is a continuous demand for improvement measures for the current status measurement method, such as having difficulties in securing a normal measurement date in consideration of equipment operation and rainfall days in the field. Results: In addition, in order to grasp the general air quality status of the evaluation target area, it is necessary to check the various current status concentrations by season and time series per year. However, there is a problem that is currently being carried out based on limited results such as measurement for 1 day or 3 days. Conclusions: Therefore, in this study, based on the national atmospheric measurement network, an inverse distance weighted (IDW) interpolation method was applied to calculate the current state concentration. This study suggested a method to use it in preparing the air quality item in the environmental impact assessment report.

Development of an Impact Force Measurement Device with an Attached Strain Gauge (스트레인게이지가 부착된 충격력 측정 장비 개발)

  • Jeong, Ik-Su
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.243-251
    • /
    • 2012
  • The purpose of this study was to develop an impact force measurement device in order to facilitate the acquisition of quantitative data for the analysis of various sporting events. The device was designed to include cylindrical aluminum supports of 220 mm diameter, which allows mounting and dismounting of the device on walls and frames. In addition, a hard sponge for impact absorption, as well as 4 springs, were attached to the plate. Both were attached to prevent psychological variables and injuries. When a subject applies force on the device, accurate data about the maximum repulsive force is acquired in real time, with a lag of only 0.001 s. The device was calibrated in four steps: (1) increase, (2) increase, (3) increase-decrease, and (4) increase-decrease. The maximum relative expanded uncertainty was 0.166%, indicating that the impact force measurement was sufficiently reliable. The proposed device can be applied to various sporting situations and is expected to be useful for studying kinetics.