Measurement uncertainty in heavy-weight floor impact sounds

측정 불확도에 따른 중량충격음 측정편차에 관한 연구

  • 유승엽 (한양대학교 건축환경공학과) ;
  • 김용희 (한양대학교 건축환경공학과) ;
  • 심명희 (한양대학교 건축환경공학과) ;
  • 전진용 (한양대학교 건축공학과)
  • Published : 2008.04.17

Abstract

In a field measurement, measurement errors are produced by measuring environments and systematic errors in the measurement procedure. Measurement errors can be expressed as a measurement uncertainty. In this study, the measurement uncertainty and various measuring factors are investigated in heavy-weight impact sounds. According to KS 2810-2, the model functions, which is the estimation of the maximum SPL measurement in each octave band frequency, are determined. From this estimation model, 3.53dB is shown in 63Hz. This level is caused by the sound field of the receiving room, which does not meet the diffusing field.

Keywords