• Title/Summary/Keyword: Illumination uniformity

Search Result 84, Processing Time 0.025 seconds

A comparative study on the light environment of the classroom classified by floor , time (강의실 빛 환경의 층별 , 시간대별 비교연구)

  • 곽경숙
    • Journal of the Korean housing association
    • /
    • v.4 no.2
    • /
    • pp.1-9
    • /
    • 1993
  • This study is a basic research to analyze and estimate the light environment of the classroom by serial correlation of time. Its purpose lies in the comparison by time period in order In select floor for laboratory and to calculate the uniformity factor. The proving ground is T building in W university, Which is five floor of central hall type. The subject of investigating is eight classrooms, four rooms in South and North, from the second floor that is net influenced by the shelter. The results that compared and estimated them in the illumination of daylight, Uniformity factor, Daylight factor, are as follows1. The illumination of classroom in South and North is over 10001x, but the classroom in North is good and the classroom in South excellent.2. The uniformity factor of classroom in South is good and that of classroom in North is normal.3. The daylight factor of each classroom is over 5% but the classroom in South is above that in North. The classroom in South surpasses the classroom in North in the general light environment and the classroom in third and fourth floor is so better than that in second and fifth floor in the condition of laboratory In the uniformity factor, the classroom in fourth can be better than any classroom.

  • PDF

Economical Efficient Evaluation of Lighting Design in Lecture Room (강의실 조명설계의 경제성 평가)

  • Kim, Deog-Goo;Oh, Seong-Bo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.268-273
    • /
    • 2004
  • The visual environment in an educational building, apart from providing the comfortable seeing conditions needed for the performance of a wide variety of work tasks, must also satisfy the psychological and emotional needs of learners. This paper presents study on actual illumination environment of college and comparison of economical efficiency in order to figure out illumination problems. Furthermore, it attempts to suggest an optimum design of lecture room illumination through computer simulation. We try to evaluate economical efficiency of lighting design in lecture room under the illumination plan which is based on illumination maintenance and uniformity ratio that KS. illumination standard sets.

  • PDF

Lightings Arrangement Method of the Small Gymnasiums (소형 옥내 운동장의 조명기구 배치방식)

  • Kim, Tae-Hoon;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.1-6
    • /
    • 2014
  • In KSC 3706, the gymnasiums are classified according to their size(small, medium, large) and there are two kinds of illumination arrangement method for them such as Side and Distributed. The characteristic of the distributed illumination arrangement method is excellent in uniformity and the characteristic of the side illumination arrangement method is excellent in glare. but illuminations were so diverse that features are not always applicable. So in this paper, in this paper, We analyzed characteristic of distributed illumination arrangement method and side illumination arrangement method using nine illumination.

Study on the Design of Asymmetric Lighting with Uniform Illumination Over a Large Area at Short Distance (단거리 조사 시 넓은 면적에 균일한 조명도를 가지는 비대칭 조명 광학계 설계 연구)

  • Kang, Dong-Hwa;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.4
    • /
    • pp.183-190
    • /
    • 2020
  • In this paper, the illuminating optics of asymmetric light distribution was studied, which allowed the light distribution to be uniform even for short-range irradiation on a wide illumination area. In the case of a light installed at a short distance, the light is not diffused enough because of the short irradiation distance. For this reason, it is difficult to satisfy uniformity of illumination. In addition, lighting design for asymmetric distribution is required because the lighting device is installed tilted, for visibility. Therefore, the design of lighting systems with asymmetric light distribution could achieve uniform illumination of the target surface even under short-distance irradiation. This was then applied to the license lamp, a lighting system featuring short light irradiation distance, to confirm that it satisfies the legal standards.

Overall Illuminance Uniformity of IRED Lighting in Nighttime CCTV

  • Sa-Gong, Geon;Park, Yung-Jun;Park, Jung-Je;Lee, Suho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2017
  • This study looks at optimizinge light redistribution to improve the overall illuminance uniformity of commercial IRED modules. To obtain uniform illumination over a prescribed rectangular area, a freeform surface lens was evaluated using TracePro. The LED light overall illuminance uniformity regulated in KSC 7658 was verified using Relux software. Experimental test results showed 0.81 overall illuminance uniformity for rectangular light distribution of LED lights having a radiation angle of $80^{\circ}$. After fabricating prototype IRED lights based on these simulation results, illuminance performance was observed when used as actual IRED lighting with a nighttime CCTV system. Image observation photographs of the prototype $80^{\circ}$ rectangular IRED lights confirmed that object images can be seen clearly owing to high overall illuminance uniformity, and that dark regions of the CCTV screen were not shown.

Fused Illumination Mechanism Design for Steel Plate Surface Inspection (철강 후판의 표면 검사를 위한 융합조명계 설계)

  • Cho, Eun Doek;Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.3
    • /
    • pp.14-19
    • /
    • 2017
  • In this paper, a fused illumination mechanism for detecting surface defects in steel plates was designed by applying the discriminant function that can differentiate the contrast of defects and non-defects. There is low contrast, non-uniformity, and no feature characteristics in steel plate surfaces. The fused illumination mechanism is devised, based on those characteristics. Optimum parameters of the fused illumination mechanism are determined by applying the discriminant function after acquiring the defect image in steel plate surfaces. The performance of the proposed mechanism is verified by experminets.

  • PDF

Lighting Analysis and Modeling on Jokcu Court (족구장 조명설비에 대한 해석 및 모델링)

  • Kim, Deog-Goo;Oh, Seong-Bo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.173-177
    • /
    • 2007
  • This paper describes the simulations on the actual measurement analysis and lighting design for recreational sports facility. Based on illumination requirements, sports may be divided into multidirectional sports and unidirectional sports. Typical multidirectional aerial sports include Jokcu. These sports require well distributed horizontal illumination and uniformity according to aiming. Therefore, this paper estimates horizontal illuminance and uniformity ratio by actual measurement of sports lighting at recreational Jokcu court in Cheju National University and evaluation of sports lighting conditions for optimal design by computer simulation.

  • PDF

A novel illumination system design for application in the integrated screen 3D display

  • Lin, Chu-Hsun;Lin, Chun-Chuan;Lo, Hsin-Hsiang;Chung, Shuang-Chao;Chen, Tian-Yuan;Wang, Chy-Lin
    • Journal of Information Display
    • /
    • v.11 no.1
    • /
    • pp.28-32
    • /
    • 2010
  • A mini-projector prototype employing a LED light source, a nontelecentric structure, and an LCOS panel for application in the integrated 3D display was fabricated. A seamless image was obtained by tilting an array of mini-projectors. Seamless quality was created by the excellent uniformity of the projection intensity on the mini-projector's screen, which was simulated as 98.34%. Great uniformity can be realized by optimizing the design of the light source and the optics configuration, which is the key to such realization.

A Study on the Actual Conditions of Living Room Lighting in Daegu and Gyeongbuk Districts (대구·경북 지역 거실 조명 실태조사)

  • Jo, Young-Mi;An, Ok-Hee;Kim, Hyun-Jin
    • Journal of the Korean housing association
    • /
    • v.23 no.3
    • /
    • pp.13-20
    • /
    • 2012
  • This research study was conducted to determine the actual conditions of living room lighting in Daegu and Gyeongbuk districts. For this study, 112 households were surveyed. The results of this study are as follows: Firstly, fluorescent light was used as the general illumination of living rooms, and the ratio of not using local sources of illumination was high. Secondly, the standard illuminance was found to be 221. The illuminance was the value that satisfied the activities for togetherness and entertainment, but did not reach the illuminance necessary for other activities, such as reading, make-up, and sewing. In addition, the uniformity of brightness used as a measure of uniformity in examining the results was normal. Thirdly, both the brightness and the satisfaction of lighting in the living room space were indicated to be normal. In addition, in regard to housing lighting, 'stability', and 'brightness of lighting' were indicated as important considerations and 'brightness of lighting', 'shadow' and 'management of lighting' were indicated as problem areas.

A Study of yield method including artificial lighting uniformity ration in interior space (실내공간에서의 인공조면 균제도 산출방법에 대한 일고찰)

  • 김현지;안옥희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.7-11
    • /
    • 1999
  • In this paper, the result of study in artificial lighting uniformity ratio yield Irethod subjtrt to lecture room are reported. It is desirable that the aWication of equation $\circled1 U=Ei/Ex\times100$ cannot be used to the rrean value in place to be efftrtive of light and darkness. And it is desirable that the awlication of equatioo $\circled2 U=Ei/Ea\times100$ or equation $\circled3 U=(Ea-Ei)/Ea\times100$ be used to the rrean Value equality illumination conditioos. Also, requiring preparation of judgarent standard, uniformity ratio equation agree with actual circumstances in this country. It must be considerai intensity of illumination and specificity of space in established standard.andard.

  • PDF