• 제목/요약/키워드: Illuminance distribution

검색결과 101건 처리시간 0.023초

표면 검사를 위한 조도 균제도 기반 하이브리드 조명계 설계 (Hybrid Illumination System Design based on Illuminance Uniformity for Surface Inspection)

  • 조은덕;김경범
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.60-65
    • /
    • 2019
  • In this paper, the hybrid illumination system for effectively detecting surface defects in steel plate with lowcontrast, non-uniformity and featureless is designed based on illuminance uniformity. First of all, characteristics of steel plate defects were considered and typical inspection illumination system is implemented. Optimum illumination parameters for uniformly illuminating an inspection area in the typical illumination system are selected based on the illuminance uniformity and illuminance distribution measurement. The illuminance uniformity and illuminance distribution are measured using an illuminometer based on the arduino. Through illuminance distribution analysis of the typical illumination, an hybrid illumination is designed by fusing bi-directional illumination and coaxial illumination. The hybrid illumination showed higher uniformity ratio and illuminance distribution than the typical illuminations. The hybrid illumination system showed the ability to uniformly illuminate the entire inspection region of steel plate surface.

미술관에서의 상부 띠형 천창의 채광분포에 관한 연구 (An Analysis of Illuminance Distribution in Fine Art Museum with Girdle Skylight Type)

  • 최만진
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.93-100
    • /
    • 2005
  • Character and illuminance distribution of daylighting is very important for the architectural plan in museum. Those data show bases for exhibition space design with daylighting and play a decisive role in visual perception of articles and space aesthetic. The goal of this paper was therefore to analyze the illuminance distribution in fine art museum with 3 typical girdle skylight types which are devided according to the art of protection from glare. This Experiment proved that they had a striking contrast with regard to the ratio of daylight illumination and illuminance distribution in spite of the same purpose of those development. The girdle skylight with a translucent glass showed the strongest value of the ratio of daylight illumination, but inequable illuminance distribution in space, excepting the area of the wall. However, the latticed reflector of light refracted daylight in the direction of wall and made illuminance distribution very equable in whole space. The ratio of daylight illumination at the girdle skylight which was located at the verge of the ceiling, was highest at the upper part of the wall and was reduced gradually from there, by way of the middle and under part of the wall, to the center of space.

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가 (Assessment of Daylight Environment on Light Pipe System Under Different Solar Position)

  • 신화영;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

반사갓의 각도에 따른 조도분포 변화 (Illuminance Distribution Variation with the Angle of Reflectors)

  • 마대영
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.16-19
    • /
    • 2010
  • In this paper, we fabricated angle-changable two-stage reflectors and measured the illuminance as a function of the angle of reflection plates. The illuminance of center areas could be controlled by changing the angle of upper reflection plates and the illuminated area expanded with reducing the angle of lower reflection plates. The bright spots could be moved using asymmetric structures of reflection plates. It was found that the distribution of illuminance matches well with the Gaussian distribution function. From the results of curve fitting, it was found that without reflectors, a half of the lights emitted from fluorescent lamp do not reach the working place. A simple model was suggested to explain the illuminance variation with the structure of reflector.

초.중.고교의 흑판조도분포 분석 (Analysis of the Illuminance Distribution on the Blackboard in Classroom of the Elementary and Senior (Junior) High School)

  • 김태현;선상권;박동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1764-1766
    • /
    • 1997
  • In this paper, the illuminance distribution of blackboards on classroom in elementary, junior, and senior high school was measured and analyzed. Generally, average illuminance and uniformity of illuminance was 519[lx] and 0.543 (elementary: 389[lx], 0.387; junior: 632[lx], 0.570; senior: 527[lx], 0.608) respectively. When all lighting fixtures in each classroom were turned on, average illuminance was higher about 65% than lights-out, and, in case that local lighting fixtures exist, was higher 27% than absence, but uniformity of illuminance turned bad on the contrary ($0.462{\rightarrow}0.676$). According to classification into direction of windows on classroom. facing north, both were bad. In case of classroom to slant to east or west, the difference of illuminance at the forenoon and afternoon was big, and uniformity of illuminance was also bad.

  • PDF

소규모 사무실의 블라인드 조건에 따른 주광조도 감소비율 예측 (Prediction of Reduction Rates of Daylight Illuminance for Blind Conditions in a Small Office)

  • Gu, Renyan
    • 토지주택연구
    • /
    • 제12권2호
    • /
    • pp.79-89
    • /
    • 2021
  • 본 연구는 다른 창가 방향에 따라 소규모 개인 사무실의 바닥과 천장의 수평 일광 분포를 분석하였다. 시뮬레이션에는 블라인드를 추가하여 다양한 일광 조도를 분석하고 비교할 수 있는 세 가지 음영 조건을 설정했다. 일광 조도 시뮬레이션을 위한 소프트웨어는 Relux였다. 실험 결과 창가에서 1m 떨어진 곳에서 조도 값이 가장 높았고 거리가 가까울수록 조도 값이 높았다. 바닥과 천장에서는 조도 차이가 12월과 6월에 각각 가장 크고 작았다. 실내 조도 값은 블라인드가 없을 때 가장 높았고, 남향 조건에서는 조도의 45°와 수평 블라인드의 차이가 가장 컸다. 북쪽 조건에서는 45°와 무 블라인드가 실내 조도에 가장 적은 영향을 미치며, 조도가 더 고르게 분배되었다.

축구 경기장의 조명타워 위치에 따른 조도분포 해석 (Illuminance Distribution Analysis by Lighting Tower Position of o Soccer Stadium)

  • 김길영;최홍규;최병숙
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2004
  • 오늘날 축구는 세계적인 주목을 받는 스포츠가 되었다. 특히, 2002 KOREA-JAPAN 월드컵은 한국에 대한 깊은 인상을 심어 주었다. 축구경기장의 조명시스템 설계에 있어서 가장 주요한 기술적 목적은 경기장의 어디에서나 최적의 분포를 나타내도록 하는 것이다. 이렇듯, FIFA는 경기장의 어디에서나 선수, 청중, 방송관계자등에게 일정한 수준의 조도를 제공할 수 있도록 규정하고 있다. 본 논문에서는 경기장의 조명타워의 위치선정에 따른 최적의 수평면 조도와 수직면 조도를 찾기 위한 알고리즘을 제시하였다. 본 논문에서는 Philip's Calculux 프로그램을 이용하여 조명타워의 위치에 따라 수평면 조도, 수직면 조도, 균제도, 글레어 등을 계산하였다.

조명기구의 배치에 따른 교실의 조도와 에너지 절약 (A Energy Saving and Illuminance of a Classroom due to the arrangement of luminaires)

  • 김이두;오세영;박희두;신종열;이수원;홍진웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2417-2419
    • /
    • 1999
  • Among educational environment, lighting's role is getting more important since it improves the visual tasks, capability of work, and it help to build both balanced mind and body. Also, since students spend most of their time inside rather than outside, students need appropriate illuminance everyday. If optimum illuminance, the color rendering properties and controlled distribution of lighting is given, people can decrease the fatigue of eyes, recover their health, and also, people can maximize their efficiency of work. In this paper, their is a comparison between the real illuminance and illuminance distribution due to the uniformity ratio of 2 or 3 dimensions by simulation.

  • PDF

Overall Illuminance Uniformity of IRED Lighting in Nighttime CCTV

  • Sa-Gong, Geon;Park, Yung-Jun;Park, Jung-Je;Lee, Suho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권1호
    • /
    • pp.35-41
    • /
    • 2017
  • This study looks at optimizinge light redistribution to improve the overall illuminance uniformity of commercial IRED modules. To obtain uniform illumination over a prescribed rectangular area, a freeform surface lens was evaluated using TracePro. The LED light overall illuminance uniformity regulated in KSC 7658 was verified using Relux software. Experimental test results showed 0.81 overall illuminance uniformity for rectangular light distribution of LED lights having a radiation angle of $80^{\circ}$. After fabricating prototype IRED lights based on these simulation results, illuminance performance was observed when used as actual IRED lighting with a nighttime CCTV system. Image observation photographs of the prototype $80^{\circ}$ rectangular IRED lights confirmed that object images can be seen clearly owing to high overall illuminance uniformity, and that dark regions of the CCTV screen were not shown.

수직형 라이트파이프의 채광성능에 관한 예비평가 (Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System)

  • 신혜미;박훈;김정태
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.