• Title/Summary/Keyword: Icp

Search Result 2,338, Processing Time 0.028 seconds

A Study on the Factors Causing Analytical Errors through the Estimation of Uncertainty for Cadmium and Lead Analysis in Tomato Paste (불확도 추정을 통한 토마토 페이스트에서 카드뮴 및 납 분석의 오차 발생 요인 규명)

  • Kim, Ji-Young;Kim, Young-Jun;Yoo, Ji-Hyock;Lee, Ji-Ho;Kim, Min-Ji;Kang, Dae-Won;Im, Geon-Jae;Hong, Moo-Ki;Shin, Young-Jae;Kim, Won-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.2
    • /
    • pp.169-178
    • /
    • 2011
  • BACKGROUND: This study aimed to estimate the measurement uncertainty associated with determination of cadmium and lead from tomato paste by ICP/MS. The sources of measurement uncertainty (i.e. sample weight, final volume, standard weight, purity, molecular weight, working standard solution, calibration curve, recovery and repeatability) in associated with the analysis of cadmium and lead were evaluated. METHODS AND RESULTS: The guide to the expression of uncertainty was used for the GUM (Guide to the expression of Uncertainty in Measurement) and Draft EURACHEM/CITAC (EURACHEM: A network of organization for analytical chemistry in Europe/Co-Operation on International Traceability in Analytical Chemistry) Guide with mathematical calculation and statistical analysis. The uncertainty components were evaluated by either Type A or Type B methods and the combined standard uncertainty were calculated by statistical analysis using several factors. Expected uncertainty of cadmium and lead was $0.106{\pm}0.015$ mg/kg (k=2.09) and $0.302{\pm}0.029$ mg/kg (k=2.16), on basis of 95% confidence of Certified Reference Material (CRM) which was within certification range of $0.112{\pm}0.007$ mg/kg for cadmium (k=2.03) and $0.316{\pm}0.021$ mg/kg for lead (k=2.01), respectively. CONCLUSION(s): The most influential components in the uncertainty of heavy metals analysis were confirmed as recovery, standard calibration curve and standard solution were identified as the most influential components causing uncertainty of heavy metal analysis. Therefore, more careful consideration is required in these steps to reduce uncertainty of heavy metals analysis in tomato paste.

Monitoring and Risk Assessment of Heavy Metals in Edible Mushrooms (국내 유통 버섯 중 중금속 함량 조사 및 위해성 평가)

  • Kim, Ji-Young;Yoo, Ji-Hyock;Lee, Ji-Ho;Kim, Min-Ji;Kang, Dae-Won;Ko, Hyeon-Seok;Hong, Su-Myeong;Im, Geon-Jae;Kim, Doo-Ho;Jung, Goo-Bok;Kim, Won-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.1
    • /
    • pp.37-44
    • /
    • 2012
  • BACKGROUND: Many edible mushrooms are known to accumulate high levels of heavy metals. This research was focused on health risk assessment to investigate the mushrooms in Korea, arsenic (As), cadmium (Cd), lead (Pb) and mercury (Hg) contaminations in edible mushrooms in cultivated areas were investigated, and health risk was assessed through dietary intake of mushrooms. METHODS AND RESULTS: The heavy metals in mushrooms were analyzed by ICP/MS after acid digestion. Probabilistic health risk were estimated by Monte-Carlo simulation techniques. The average contents of As, Cd, Pb, and Hg were $0.035{\pm}0.042$ mg/kg, $0.017{\pm}0.020$ mg/kg, $0.043{\pm}0.013$ mg/kg, and $0.004{\pm}0.004$ mg/kg, respectively. The results showed that contents of Cd and Pb did not exceed maximum residual levels established by European Uion regulation (Cd 0.20 mg/kg and Pb 0.30 mg/kg). For health risk assessment, estimated intakes in all age populations did not exceed the provisional tolerable daily intake of As and Hg, provisional tolerable monthly intake of Cd, provisional tolerable weekly intake of Pb. The Hazard Index (HI) were ranged from $0.03{\times}10^{-4}{\sim}0.01{\times}10^{-3}$ for As, $0.02{\times}10^{-3}{\sim}0.81{\times}10^{-3}$ for Cd, $0.06{\times}10^{-3}{\sim}0.38{\times}10^{-3}$ for Pb, and $0.08{\times}10^{-4}{\sim}0.14{\times}10^{-3}$ for Hg at general population. CONCLUSION: The HI from the ratio analysis between daily exposure and safety level values was less than 1.0. This results demonstrated that human exposure to heavy metals through dietary intake of mushrooms might not cause adverse effect.

Monitoring of Lead and Cadmium Contents of Vegetables in Korea (국내 유통 중인 채소류의 납, 카드뮴 함량 모니터링)

  • Shim, Jee-Youn;Oh, Hyun-Suk;Jang, Mi-Ran;Lee, Yoon-Ae;Lee, Ryun-Kyung;Kim, Min-A;Lee, Hyo-Jung;Lee, Sang-Min;Cho, Tae-Youg
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.395-401
    • /
    • 2010
  • This research was carried out as a survey on the contents of Lead (Pb) and Cadmium (Cd) in 5 type agricultural products unestablished safety guideline in Korea. The average levels of Pb: onion 0.010 mg/kg, cucumber 0.018 mg/kg, garlic 0.012 mg/kg, green pepper 0.027 mg/kg, sesame 0.029 mg/kg. The average levels of Cd: onion 0.006 mg/kg, cucumber 0.002 mg/kg, garlic 0.008 mg/kg, green pepper 0.011 mg/kg, sesame 0.024 mg/kg. The present result of this study showed that Pb and Cd contents in the whole samples were less than the maximum residual levels of the codex standard. The levels of exposure assessment for Pb and Cd by intake from vegetables and sesame were merely at $1.3{\times}10^{-4}$(mean) ~ $5.1{\times}10^{-4}$($95^{th}$ percentiles) ${\mu}$g/kg bw/day for Pb, $7.5{\times}10^{-5}$(mean) ~ $3.6{\times}10^{-4}$($95^{th}$ percentiles) ${\mu$}g/kg bw/day for Cd. The data from this research will be valuable source for database construction for science-based safety control and management for the trace metal contamination in food including agricultural products.

A Study on Heavy Metal Concentrations of Color Cosmetics in Korea Market (국내시판 중인 색조화장품의 중금속 농도에 관한 연구)

  • Choi, Chae Man;Hwang, Young Sook;Park, Ae Sook;Jung, Sam Ju;Kim, Hyun Jung;Kim, Jung Hun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.3
    • /
    • pp.269-278
    • /
    • 2014
  • This study aimed to provide the fundamental data on the field of cosmetics by comparing heavy metal concentration in terms of domestic/foreign products, types and colors. The study determined the concentrations of lead, cadmium, arsenic, chromium, antimony, nickel, copper and cobalt in cosmetics such as lipstick, lip gloss, lip balm, foundation and eye liner. From the period of January to August, 2013, 121 samples were collected from cosmetic stores distributing to the general market. The average metal concentrations were as follows; $0.663{\mu}g/g$ for lead, $0.010{\mu}g/g$ for cadmium, $0.056{\mu}g/g$ for arsenic, $1.144{\mu}g/g$ for chromium, $0.008{\mu}g/g$ for antimony, $0.405{\mu}g/g$ for nickel, $0.319{\mu}g/g$ for copper and $0.108{\mu}g/g$ for cobalt. Except for chromium, the heavy metal concentrations were significantly higher in foreign products than in domestic products (p < 0.05). Also, The mean concentrations of heavy metal were significantly different (p < 0.05) when classified by cosmetic type. The highest mean concentrations shown in lipstick were $1.430{\mu}g/g$ of chromium, $0.616{\mu}g/g$ of lead and $0.385{\mu}g/g$ of nickel, in foundation $1.155{\mu}g/g$ of lead and $1.023{\mu}g/g$ of chromium. In eye liner, the highest mean concentrations were $1.424{\mu}g/g$ of chromium and $0.830{\mu}g/g$ of nickel. Additionally, The concentrations of heavy metal were significantly different by color (p < 0.05). Brown colored cosmetics were found to have the highest mean concentrations of chromium, nickel and copper, ivory colored cosmetics the highest mean concentrations of chromium and lead, and pink colored cosmetics the highest concentrations of lead and chromium.

The Effect of HCl Gas on Selective Catalytic Reduction of Nitrogen Oxide (질소산화물의 선택적 환원 제거시 염화수소기체가 촉매에 미치는 영향)

  • Choung, Jin-Woo;Choi, Kwang-Ho;Seong, Hee-Je;Chai, Ho-Jung;Nam, In-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.609-617
    • /
    • 2000
  • This study is aimed at investigating an effect of HCl gas on selective reduction of NOx over a CuHM and $V_2O_5-WO_3/TiO_2$ catalyst. SCR process is the most effective method to remove NOx, but catalyst can be deactivated by the acidic gas such as HCl gas which is also included in flue gas from the incinerator. In dry condition of flue gas, the CuHM catalyst treated by HCl gas has shown higher NO removal activity than the fresh catalyst. The activity of the catalyst can be restored by treating at $500^{\circ}C$. On the contrary. $V_2O_5-WO_3/TiO_2$ catalyst is obviously deactivated by HCl and the deactivation increases in proportion to the concentration of HCl gas. The deactivated catalyst is not restored to it's original activity by heat treatment for regeneration. In wet flue gas stream, the CuHM catalyst has shown lower activity than fresh catalyst and $V_2O_5-WO_3/TiO_2$ catalyst was severely deactivated by HCl treatment. The activity loss of catalysts are mainly due to the decrease of Br$\ddot{o}$nsted acid site on the catalyst surface by $NH_3$ TPD. The change of BET surface area of CuHM catalyst after the reaction isn't observed but $V_2O_5-WO_3/TiO_2$ catalyst is observed. The amount of $Cu^{{+}{+}}$ and $V_2O_5$ is decreased after the reaction. From these results, it is expected that CuHM catalyst should be better than $V_2O_5-WO_3/TiO_2$ catalyst for its application to the incineration of flue gas.

  • PDF

A Study on Heavy Metal Concentrations of Oxidized Hair Coloring Products in Korea Market (한국에서 유통 중인 산화형 염모제의 중금속 농도에 관한 연구)

  • Choi, Chae Man;Hong, Mi Sun;Lee, Yun Jung;Kim, Hwa Soon;Kim, Hyun Jung;Kim, Jung Hun;Chae, Young Zoo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.3
    • /
    • pp.241-249
    • /
    • 2013
  • This study was aimed to provide the fundamental data about oxidized hair color products. For this reason, we collected 125 oxidized hair color products, which were distributed in domestic market from January to October, 2012, and measured the heavy metal concentrations of lead, arsenic, cadmium, chromium, manganese, nickel, copper in the samples. Results were compared by domestic, foreign, henna, type and color. The average metal concentrations were as follows; 0.211 ${\mu}g/g$ for lead, 0.008 ${\mu}g/g$ for cadmium, 0.051 ${\mu}g/g$ for arsenic, 0.954 ${\mu}g/g$ for chromium, 6.250 ${\mu}g/g$ for manganese, 0.591 ${\mu}g/g$ for nickel and 0.544 ${\mu}g/g$ for copper. In case of lead and arsenic, the concentrations were much less than the regulated amount (20 ${\mu}g/g$ and 10 ${\mu}g/g$, respectively) suggested by MFDS (Ministry of Food and Drug Safety). In henna (p < 0.05), the concentrations were significantly higher than those of other domestic and foreign oxidized hair color products as follows; 1.264 ${\mu}g/g$ for lead, 0.267 ${\mu}g/g$ for arsenic, 0.025 ${\mu}g/g$ for cadmium, 4.055 ${\mu}g/g$ for chromium, 72.044 ${\mu}g/g$ for manganese, 3.076 ${\mu}g/g$ for nickel and 4.640 ${\mu}g/g$ for copper. Statistically, it showed that the heavy metal concentrations were quite different for the different types of hair color products. The cream and liquid type products had the highest average concentration in chromium (0.708 ${\mu}g/g$, 0.478 ${\mu}g/g$, respectively). On the other hand, powder type products showed the highest concentration in manganese (60.041 ${\mu}g/g$). In addition, the concentrations of heavy metals and the color of products are not quite correlated. It was shown that average concentrations of lead and chromium were higher for yellow, chromium for red and pink, manganese for brown and black, and nickel for green.

HYDROLYTIC DEGRADATION OF POSTERIOR RESIN RESTORATIVE MATERIALS (구치부 레진 수복 재료의 가수분해)

  • Yang, Kuy-Ho;Park, Mi-Ran;Choi, Nam-Ki;Park, Eun-Hae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.673-682
    • /
    • 2001
  • The use of resin composites has continued to increase over the last several years. In spite of their growing popularity, composites continue to exhibit a number of undesirable characteristics. One of the major deficiencies of composite restorative resins is their inadequate resistance to wear. Of the multitude of factors that have been associated with wear, subsurface degradation within the restoration is considered to be one. The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. This solution with a high concentration of hydroxyl ions is a convenient medium for accelerated degradation of silane coupling and filler particles. The brands studies were Definite($Degussa-H\ddot{u}ls$ AG, Germany), Prodigy(Kerr, USA), Pyramid(Bisco, USA) and Synergy(Coltene, Swiss). Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters : (a) mass loss(%)-determined from pre-and post-exposed specimen weights : (b) Si loss(ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation $depth({\mu}m)$-measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. Mass loss of Synergy was $1.24{\pm}0.002%$, it was the highest, there was no significant difference among the materials. 2. The degree of degradation layer depth of Synergy was $107.83{\pm}2.52{\mu}m$, it was the highest, there was no significant difference among any other materials than Synergy. 3. There was no difference among the four materials in Si loss. 4. The correlation coefficient between mass loss and degradation depth was relatively high(r=0.06, p<0.05). 5. There was no coefficient correlation between Si loss and mass loss, the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler.

  • PDF

Study of the Characteristics of Roasted Coffee Bean in Seoul (서울시 유통 원두커피의 품질 특성)

  • Cho, In-soon;Hong, Mi-sun;Lee, Eun-seon;Kim, Si-jung;Lee, Yong-cheol;Kim, Sung-dan;Jo, Han-bin;Kim, Jung-hun;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.3
    • /
    • pp.236-241
    • /
    • 2015
  • This study was performed to survey and evaluate the contents of pH, total acidity, caffeine, harmful metals (Pb, Cd) and total polyphenol in coffee extraction. In total, coffee bean. Total fifty coffee samples were analysed. A 5 g portion of roasted ground coffee samples were extracted in coffee-maker with 100 mL of distilled water and the extraction were used in all experiments. The pH range was 4.72~5.25 (mean value = 4.99). According to increase of the roasting temperature, the pH were shown a tendency to increase. The contents of total acidity was 0.72~2.25% (mean value = 1.59%). According to increase of the roasting temperature, the contents of total acidity were shown a tendency to decrease. The contents of harmful metals (Pb, Cd) in coffee extractions were determined by ICP. The average contents of Pb and Cd were 0.0112 and 0.0011 mg/kg, respectively. The contents of caffeine in coffee extractions were determined by HPLC, the range of detection was 0.51~20.28 mg/mL (mean value = 12.29 mg/mL). According to increase of the roasting temperature, the contents of caffeine were shown a tendency to increase. The contents of total polyphenol in coffee extractions were determined by spectrophotometer, the range of detection was 18.88~43.90 mg/mL (mean value = 31.94 mg/mL). According to increase of the roasting temperature, the contents of total polypenol were shown a tendency to decrease.

Monitoring of Heavy Metals Migrated from Polylactide (PLA) Food Contact Materials in Korea (국내 유통 폴리락타이드(PLA) 식품용 기구 및 용기·포장의 중금속 이행량 모니터링)

  • Kim, Hyeonuk;Park, So-Yeon;Jo, Ye-Eun;Park, Yongchjun;Park, Se-Jong;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.102-109
    • /
    • 2018
  • In the present study, a variety of polylactide (PLA) articles (n = 211) were tested for migration of lead (Pb), cadmium (Cd) and arsenic (As) into the food simulant (4% v/v acetic acid). Pb, Cd, and As were analyzed by inductively coupled plasma mass spectrometry (ICP-MS). Migration tests were performed at $70^{\circ}C$ and $100^{\circ}C$ for 30 min. The amounts of Pb, Cd, and As increased at $100^{\circ}C$ for 30 min compared with levels at $70^{\circ}C$. However, the migration at both conditions was very low. The maximum level of Pb at $100^{\circ}C$ for 30 min corresponded to 1% of the migration limit. The estimated daily intakes (EDI) based on safety evaluation ranged from $2.5{\times}10^{-5}$ to $2.0{\times}10^{-3}{\mu}g/kg\;bw/day$ for Pb, Cd, and As. The EDI calculated from migration of Pb at $100^{\circ}C$ for 30 min in PLA was the maximum value, $2.0{\times}10^{-3}{\mu}g/kg\;bw/day$, which corresponded to 0.055% of provisional tolerable weekly intake (PTWI, $25{\mu}g/kg\;bw/week$). The data from this study represent a valuable source for science-based safety control and management of hazardous heavy metals migrating from polylactide food contact materials.

A Study on Heavy Metal Contamination and Risk Assessment of Seaweed and Seaweed Products (해조류와 해조류가공품의 중금속 오염실태 및 위해성평가)

  • Lee, Ji-Yeon;Lee, Myung-Jin;Jeong, Il-Hyung;Cho, Young-Sun;Sung, Jin-Hee;Baek, Eun-Jin;Lee, Eun-Bin;Kim, Hye-Jin;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.5
    • /
    • pp.447-453
    • /
    • 2019
  • In this study, the contamination of 4 types of heavy metals (lead, cadmium, arsenic, and mercury) was monitored in 80 seaweeds and their processed products, and a food safety assessment was also carried out for these heavy metals. Lead, cadmium and arsenic were analyzed by ICP-OES and mercury was analyzed by mercury analyzer. The detection ranges of heavy metals were found as follows: Pb (N.D-0.802 mg/kg), Cd (N.D-0.759 mg/kg), As (0.134-17.296 mg/kg), and Hg (0.0005-0.0331 mg/kg). Pb and Hg showed no significant differences among seaweeds whereas Cd and As were significantly higher in the species hizikia fusiforme (P<0.05). Food safety assessment from seaweed intake was measured by PTWI (Provisional Tolerable Weekly Intake), PTMI (Provisional Tolerable Monthly Intake), and MADL (Maximum Allowable Daily Body Load) as set by JECFA (Joint FAO/WHO Expert Committee on Food Additives). Pb and Hg were 0.197%, 0.036% of PTWI respectively, while Cd was 1.877% of PTMI and As was 0.619% of MADL. Therefore, it was found that heavy metal levels of seaweed were low and was considered to be safe for consumption.