• 제목/요약/키워드: Icp

검색결과 2,338건 처리시간 0.032초

MFMIS 게이트 구조에서의 메모리 윈도우 특성 (Characteristics of Memory Windows of MFMIS Gate Structures)

  • 박전웅;김익수;심선일;염민수;김용태;성만영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.319-322
    • /
    • 2003
  • To match the charge induced by the insulators $CeO_2$ with the remanent polarization of ferro electric SBT thin films, areas of Pt/SBT/Pt (MFM) and those of $Pt/CeO_2/Si$ (MIS) capacitors were ind ependently designed. The area $S_M$ of MIS capacitors to the area $S_F$ of MFM capacitors were varied from 1 to 10, 15, and 20. Top electrode Pt and SBT layers were etched with for various area ratios of $S_M\;/\;S_F$. Bottom electrode Pt and $CeO_2$ layers were respectively deposited by do and rf sputtering in-situ process. SBT thin film were prepared by the metal orgnic decomposition (MOD) technique. $Pt(100nm)/SBT(350nm)/Pt(300nm)/CeO_2(40nm)/p-Si$ (MFMIS) gate structures have been fabricated with the various $S_M\;/\;S_F$ ratios using inductively coupled plasma reactive ion etching (ICP-RIE). The leakage current density of MFMIS gate structures were improved to $6.32{\times}10^{-7}\;A/cm^2$ at the applied gate voltage of 10 V. It is shown that in the memory window increase with the area ratio $S_M\;/\;S_F$ of the MFMIS structures and a larger memory window of 3 V can be obtained for a voltage sweep of ${\pm}9\;V$ for MFMIS structures with an area ratio $S_M\;/\;S_F\;=\;6$ than that of 0.9 V of MFS at the same applied voltage. The maximum memory windows of MFMIS structures were 2.28 V, 3.35 V, and 3.7 V with the are a ratios 1, 2, and 6 at the applied gate voltage of 11 V, respectively. It is concluded that ferroelectric gate capacitors of MFMIS are good candidates for nondestructive readout-nonvolatile memories.

  • PDF

Magnetized inductively coupled plasma etching of GaN in $Cl_2/BCl_3$ plasmas

  • Lee, Y.H.;Sung, Y.J.;Yeom, G.Y.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 1999년도 추계학술발표회 초록집
    • /
    • pp.49-49
    • /
    • 1999
  • In this study, $Cl_2/BCI_3$ magnetized inductively coupled plasmas (MICP) were used to etch GaN and the effects of magnetic confinements of inductively coupled plasmas on the GaN etch characteristics were investigated as a function of $Cl_2/BCI_3$. Also, the effects of Kr addition to the magnetized $Cl_2/BCI_3$ plasmas on the GaN etch rates were investigated. The characteristics of the plasmas were estimated using a Langmuir probe and quadrupole ma~s spectrometry (QMS). Etched GaN profiles were observed using scanning electron microscopy (SEM). The small addition of $Cl_2/BCI_3$ (10-20%) in $Cl_2$ increased GaN etch rates for both with and without the magnetic confinements. The application of magnetic confinements to the $Cl_2/BCI_3$ inductively coupled plasmas (ICP) increased GaN etch rates and changed the $Cl_2/BCI_3$ gas composition of the peak GaN etch rate from 10% $BCI_3$ to 20% $BCI_3$. It also increased the etch selectivity over photoresist, while slightly reducing the selectivity over $Si0_2$. The application of the magnetic field significantly increased positive $BCI_2{\;}^+$ measured by QMS and total ion saturation current measured by the Langmuir probe. Other species such as CI, BCI, and CI+ were increased while species such as $BCl_2$ and $BCI_3$ were decreased with the application of the magnetic field. Therefore, it appears that the increase of GaN etch rate in our experiment is related to the increased dissociative ionization of $BCI_3$ by the application of the magnetic field. The addition of 10% Kr in an optimized $Cl_2/BCI_3$ condition (80% $Cl_2/$ 20% $BCI_3$) with the magnets increased the GaN etch rate about 60%. More anisotropic GaN etch profile was obtained with the application of the magnetic field and a vertical GaN etch profile could be obtained with the addition of 10% Kr in an optimized $Cl_2/BCI_3$ condition with the magnets.

  • PDF

한방처방의 전탕 전과 후의 위해물질 농도변화 -보양.보음 처방을 중심으로 - (Concentration of Hazardous Substances of before/after a Decoction in Prescription of Herbal Medicine -In Prescription of tonify Yang and tonify Yin-)

  • 서창섭;황대선;이준경;하혜경;천진미;엄영란;장설;신현규
    • 대한한의학방제학회지
    • /
    • 제17권2호
    • /
    • pp.53-63
    • /
    • 2009
  • Objective : To compare the contents of heavy metals, residual pesticides and sulfur dioxide before/after a decoction. Methods : The heavy metal contents before/after a decoction were measured by Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) and mercury analyzer. In order to analyze pesticides in 4 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide ($SO_2$) were performed by Monier-Williams distillation method. Results: 1. The mean values of heavy metal contents (mg/kg) for the samples were as follows: Jaeumganghwa-tang (before decoction - Pb; 1.190, Cd; 0.184, As; 0.099 and Hg; 0.028, after decoction - Pb; .033, Cd; 0.003, As; 0.005 and Hg; 0.001), Yukmijiwhang-tang (before decoction - Pb; 0.484, Cd; 0.133, As; 0.053 and Hg; 0.009, after decoction - Pb; 0.065, Cd; 0.008, As; 0.007 and Hg; not detected), Bojungikgi-tang (before decoction - Pb; 0.863, Cd; 0.197, As; below 0.016 and Hg; 0.011, after decoction - Pb; 0.071, Cd; 0.009, As; 0.004 and Hg; 0.001) and Ssangwha-tang (before decoction - Pb; 1.511, Cd; 0.212, As; 0.094 and Hg; 0.016, after decoction - Pb; 0.029, Cd; 0.006, As; 0.005 and Hg; 0.0004). 2. Contents (mg/kg) of sulfur dioxide ($SO_2$) before a decoction in Jaeumganghwa-tang, Yukmijiwhang-tang and Ssangwha-tang exhibited 22.7, 107.3 and 5.5, respectively. However, contents of sulfur dioxide after a decoction in all samples were not detected. 3. Contents (mg/kg) of residual pesticides before/after a decoction in all samples were not detected. Conclusion : These results will be used to establish a criterion of heavy metals, residual pesticides and sulfur dioxide.

  • PDF

전탕 전과 후의 중금속, 잔류농약 및 잔류이산화황의 농도변화 - 십전대보탕 구성처방을 중심으로 - (Concentration of Heavy Metals, Residual Pesticides and Sulfur Dioxide before/after a Decoction - In Prescription consist of Sipjeondaebo-tang -)

  • 서창섭;황대선;이준경;하혜경;천진미;엄영란;장설;신현구
    • 대한한의학회지
    • /
    • 제30권4호
    • /
    • pp.108-117
    • /
    • 2009
  • Objective: To compare the contents of heavy metals, residual pesticides and sulfur dioxide before/after a decoction. Methods: The heavy metal contents before/after a decoction were measured by inductively-coupled plasma atomic emission spectrometer (ICP-AES) and mercury analyzer. In order to analyze pesticides in 5 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide ($SO_2$) were performed by Monier-Williams distillation method. Results: 1. The mean values of heavy metal contents (mg/kg) for the samples were as follows: Sipjeondaebo-tang (before decoction - Pb; 1.163, Cd; 0.257, As; 0.080 and Hg; 0.016, after decoction - Pb; 0.059, Cd; 0.007, As; 0.006 and Hg; 0.0003), Palmul-tang (before decoction - Pb; 1.181, Cd; 0.242, As; 0.152 and Hg; 0.014, after decoction - Pb; 0.067, Cd; 0.008, As; 0.008 and Hg; 0.0003), Sagunja-tang (before decoction - Pb; 1.285, Cd; 0.283, As; 0.063 and Hg; 0.012, after decoction - Pb; 0.047, Cd; 0.009, As; 0.004 and Hg; not detected) and Samul-tang (before decoction - Pb; 1.025, Cd; 0.169, As; 0.099 and Hg; 0.013, after decoction - Pb; 0.065, Cd; 0.007, As; 0.010 and Hg; 0.001). 2. Contents (mg/kg) of residual pesticides before/after a decoction were not detected in any samples. 3. Contents (mg/kg) of sulfur dioxide ($SO_2$) before a decoction in Sipjeondaebo-tang, Palmul-tang, Sagunja-tang and Samul-tang exhibited 5.0, 6.0, 14.0 and 6.9, respectively. However, contents of sulfur dioxide after a decoction were not detected in any samples. Conclusion: These results will be used to establish a criterion for heavy metals, residual pesticides and sulfur dioxide.

  • PDF

골유착성 임플랜트 보철물 장착시 하악골의 탄성변형 및 응력분포에 관한 삼차원 유한요소법적 연구 (A STUDY ON THE ELASTIC DEFORMATION AND STRESS DISTRIBUTION OF THE MANDIBLE WITH OSSEOINTEGRATED IMPLANT PROSTHESES USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS METHOD)

  • 김용호;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.203-244
    • /
    • 1998
  • The human mandible is always under the condition of loading by the various forces extorted by the attached muscles. The loading is an important condition of the stomatognathic system. This condition is composed of the direction and amount of forces of the masticatory muscles, which are controlled by the neuromuscular system, and always influenced by the movement of both opening and closing. Mandible is a strong foundation for the teeth or various prostheses, nevetheless it is a elastic body which accompanies deformation by the external forces on it. The elastic properties of the mandible is influenced by the various procedures such as conventional restorative treatments, osseointegrated implant treatments, reconstructive surgical procedures and so forth. Among the treatments the osseointegrated implant has no periodontal ligaments, which exist around the natural teeth to allow physiologic mobility in the alveolar socket. And so around the osseointegrated implant, there is almost no damping effect during the transmission of occlusal stress and displacements. If the osseointegrated implants are connected by the superstructure for the stabilization and effective distribution of occlusal stresses, the elastic properties of mandible is restricted according to the extent of 'splinting' by the superstructure and implants. To investigate the change of elastic behaviour of the mandible which has osseointegrated implant prosthesis of various numbers of implant installment and span of superstructre, a three dimensional finite element model was developed and analyzed with conditions mentioned above. The conclusions are as follows : 1. The displacements are primarily developed at the area of muscle attachment and distributed all around the mandible according to the various properties of bone. 2. The segmentation in the superstructure has few influence on the distribution of stress and displacement. 3. In the load case of ICP, the concentration of tensional stress was observed at the anterior portion of the ramus($9.22E+6N/m^2$) and at the lingual portion of the symphysis menti($8.36E+6N/m^2$). 4. In the load case of INC, the concentration of tensional stress was observed at the anterior portion of the ramus($9.90E+6N/m^2$) and the concentration of tensional stress was observed at the lingual portion of the symphysis menti($2.38E+6N/m^2$)). 5. In the load case of UTCP, the relatively high concentration of tensional stress($3.66E+7N/m^2$) was observed at the internal surface of the condylar neck.

  • PDF

다년생 근채류 중 중금속 모니터링 및 위해성평가 (Monitoring and Risk Assessment of Heavy Metals in Perennial Root Vegetables)

  • 조민자;최훈;김혜정;윤혜정
    • 한국환경농학회지
    • /
    • 제35권1호
    • /
    • pp.55-61
    • /
    • 2016
  • 다년생 근채류인 인삼, 산양삼, 더덕, 도라지의 중금속 함량 실태조사를 통해 우리나라 국민의 식품 섭취로 인한 중금속 노출수준에 따른 위해성을 평가하였으며, 이를 위해 총 214건을 수거하였다. 근채류 중 납, 카드뮴 및 비소 함량분석을 위해 microwave장치를 이용해 전처리한 후 ICP/MS로 측정하는 시험법을 확립하였다. 중금속의 검출한계는 0.010~0.050 μg/kg이었으며 정량한계는 0.035~0.175 μg/kg이었다. 표준용액 첨가법과 CRM을 이용하여 회수율을 실험한 결과, 76~102%의 양호한 결과를 얻었다. 다년생 근채류 중 납 함량은 평균 0.013(인삼)~0.070(산양삼) mg/kg이었고, 카드뮴 함량은 평균 0.009(인삼)~0.034(더덕) mg/kg이었으며 비소 함량은 평균 0.002(인삼)~0.004(도라지) mg/kg이었다. 다년생 근채류 섭취에 따른 중금속 위해성 평가를 수행한 결과, 중금속 노출량은 각각 Pb 0.070 μg/day, Cd 0.041 μg/day, As 0.008 μg/day으로 인체섭취한계량의 0.03%, 0.08%, 0.0003% 수준이었다. 따라서, 국내 유통되는 인삼, 산양삼, 더덕 및 도라지 섭취로 인한 중금속 노출수준은 JECFA 등의 인체노출안전기준보다 매우 낮았으며 우리나라 국민은 다년생 근채류에 존재하는 중금속의 위해성으로부터 안전하였다.

석고 및 석고 슬러리에 대한 분석방법의 비교 (The Comparison of Analytical Methods for Gypsum and Gypsum Slurry)

  • 김경숙;양석란;박현주;임춘식
    • 분석과학
    • /
    • 제13권2호
    • /
    • pp.158-165
    • /
    • 2000
  • 배연탈황설비에서 생성된 석고 슬러리 및 석고의 순도와 불순물의 정량분석은 시운전중인 탈황설비의 성능시험시 최적의 탈황공정을 모색하는 데 유용한 자료를 제공할 뿐만 아니라 생성된 석고는 시멘트나 석고 보드 등으로 사용될 수 있으므로 품질관리의 측면에서도 매우 중요하다. 석고의 순도는 결합수분, 삼산황 및 칼슘이온의 농도를 측정한 다음 환산식에 의해서 gypsum($CaSO_4{\cdot}2H_2O$)의 형태로 변환할 수 있다. 성능시험시 시료의 수가 상당히 많으므로, 좀 더 간편하면서도 정확한 분석방법의 확립을 위해 여러가지 비교실험을 실시한 결과, 열분석을 통하여 결합수분을 측정하는 방법이 1시간 이내에 분석이 완료된다는 장점 외에 재현성 또한 아주 우수하였다. 그 외 실리카를 포함한 각종 석고의 불순물의 분석은 산으로 처리하는 방법과 융제를 사용한 용융법을 비교한 결과, 용융법이 훨씬 간편하고 정확한 결과를 나타내었다. 한편 소량의 탄산 마그네슘과 탄산 칼슘의 정량을 위해 사용되는 이산화탄소 측정장치의 트랩부분을 수정하여 이산화탄소 흡수제의 역류를 막도록 하였다. 열분석을 통한 결함수분 측정, 융제를 사용한 용융법 및 이산화탄소의 정량법으로 확립된 분석 방법을 통해 석고 슬러리 및 석고의 분석은 보다 짧은 시간내에 간편하면서도 정확하게 실시될 수 있음을 확인하였다.

  • PDF

유도결합플라즈마 질량분석법을 이용한 혈장 중 극미량 납 분석 (Trace level analysis of Pb in plasma by inductively coupled plasma/mass spectrometry)

  • 이성배;양정선;최성봉;신호상
    • 분석과학
    • /
    • 제25권3호
    • /
    • pp.190-196
    • /
    • 2012
  • 납에 의한 노출에 대한 평가에는 주로 전혈 중 납을 사용하고 있으나 전혈 중 납은 납의 단기 노출에 대한 정보만을 제공한다는 단점이 있다. 납 노출의 만성적 노출지표인 혈장 중 납을 분석하기 위해서는 수 ng/L의 극미량 분석이 요구되어 납의 만성지표로서의 효용성 검증에 어려움이 있다. 본 연구에서는 납 노출 근로자의 만성 노출 지표로서 혈장 중 납을 분석하기 위하여 유도결합플라즈마 질량분석법을 정립하였다. 외부환경으로부터의 오염을 최소화시키기 위해 class 1,000 수준의 청정실을 설치한 후 가동 전과 후의 부유 분진량을 확인한 후 극미량 시료 분석을 수행하였다. 표준 우태아 혈청을 이용하여 표준물 첨가법에 의한 표준편차를 이용하여 계산한 최소검출한계는 4.3 ng/L, 최소정량한계는 12.2 ng/L이었으며, 신호-대-잡음 비로 계산한 최소검출한계는 7.0 ng/L, 최소정량한계는 22.1 ng/L이었다. 20 ng/L부터 2,000 ng/L 농도 범위에서 정밀도는 4% 이내였으며, 우태아 혈청에 20-2,000 ng/L의 농도로 첨가하여 계산한 회수율은 92.3-101.3%로 양호한 결과를 얻었다. 본 연구에서 제시한 방법을 사용하여 납 노출근로자의 혈장 및 혈청 중 납 분석이 가능하였으며 이를 통해 납의 만성노출에 대한 조사가 가능할 것으로 판단된다.

Korean solar salts reduce obesity and alter its related markers in diet-induced obese mice

  • Ju, Jaehyun;Song, Jia-Le;Park, Eui-Seong;Do, Myoung-Sool;Park, Kun-Young
    • Nutrition Research and Practice
    • /
    • 제10권6호
    • /
    • pp.629-634
    • /
    • 2016
  • BACKGROUND/OBJECTIVE: The aim of this experiments was to show anti-obesity effects of Korean solar salt from different salt fields in diet-induced obese mice. MATERIALS/METHODS: Diet-induced obesity (DIO) was induced by a high-fat diet (HFD; 45% cal from fat) in C57BL/6J mice for eight weeks. The mice were fed with the designated diets (chow diet for Normal, HFD for Control, 0.47%-salt-mixed HFD for purified salt (PS), Guerande solar salt from France (SS-G), solar salt from Y salt field (SS-Y), solar salts from T salt field (SS-T) and S salt field (SS-S)) for another eight weeks. We checked body weight, food efficiency ratio (FER) and tissue weights (liver and epididymal adipose tissue (EAT)), and observed serum concentrations of triacylglycerol (TG), total cholesterol (TC), leptin and insulin. We also evaluated gene expressions of adipogenic / lipogenic mRNAs of $C/EBP{\alpha}$, $PPAR{\gamma}$ and FAS and beta-oxidation-related factors ($PPAR{\alpha}$ and CPT-1) in liver and EAT. The mineral composition of salt samples were analyzed using inductively coupled plasma optical emission spectrometry (ICP-OES). RESULTS: SS-T and SS-S significantly reduced body weight gain, FER, and weight of EAT compared to control and other samples (P < 0.05). SS-T and SS-S also significantly decreased serum levels of TG, TC, leptin and insulin (P < 0.05). SS-T and SS-S suppressed expressions of adipogenic / lipogenic mRNAs in liver and EAT, while promoting expression of beta-oxidation-related factors. The lowest sodium concentration was observed in SS-T ($30.30{\pm}0.59%$), and the lowest sodium-to-potassium (Na/K) ratio was found in SS-S (17.81). CONCLUSIONS: Our study shows that well-processed Korean solar salt may have anti-obesity effects in vivo, probably owing to its differences in mineral composition and other components, presumably resulting from the manufacturing processes. Further research is needed into the mechanism and to explore optimal manufacturing processes.

대면적 Transformer coupled Plasma Source에서 파워결합에 관한 실험적 연구

  • 김희준;손명근;황용석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.166-166
    • /
    • 1998
  • 반도체 공정에서 기존보다 큰 30cm 웨이퍼훌 이용하기 위해서 기존의 ECR, Helicon, ICP, 등 공정용 고 밀도 플라즈마 원들의 대면적화에 대한 연구가 세계적으로 진행되고 있다 현 상황에서는 평판형 안테 나룰 이용한 TCP가 대면적용 폴라즈마 원의 가장 유력한 후보로 여겨지고 있다 TCP롤 대면적화 하는 데 있어서 중요한 문제점으로는 대면적에서의 큰 안테나 인되턴스로 인한 임피던스 정합과 대면적에서 의 유전울질의 기계적 강도이다. 앓은 유전물질올 사용힐 수 있도록 대면적 TCP 플라즈마 원올 실계 저l작하였고 이차원 가열이론올 이용한 TCPRP code 률 이용하여 안테나의 반경옳 결정하였디 안테나의 인덕턴스 값올 줄이기 위해서는 주m수는 13.56MHz 보다 낮은 4-5MHz 부근에서 작동하는 RF 파워룰 선택하였다 이 파워 서플라이는 보통 사용되는 50n 흩력 입묘$\mid$던스훌 갖는 형태가 Of니라 LC 공진현상 올 이용하여 부하에 파워률 전달하는 형태이다 .. TCP 장치에 사용할 수 있도록 파워 서플라이 흩력 단에 안테나와 직혈로 가변 콘덴서를 달아서 임11I던스 정합올 힐 수 있게 하였다 안테나에 직훌로 달Of줌으 로써 안테니의 인덕턴스훌 훌여주는 효과훌 얻올 수 있다 안테나에 흐르는 전류룰 측정하기 위해서 사 각형 루프로 전류 픽업 코일을 만들었고 진공상태에서 RF 파워률 인가하고 안테나의 전류와 전압을 측정하여 픽업 코일걸과훌 조정하였다. 발생기체로는 헬륨올 사용하였고 1-100mTorr 의 압력범위에서 실험을 하였다 플라즈마롤 빌샘시키고 파워를 증가 시킴에 따라 E-H mode transition 현상이 관찰되었고 그 때의 임계 전류 값을 측정하였다. 압력이 낮올수록 모드 변화가 일어나는 전류의 값이 작았다 임계 전류는 압력에 대해서 선형적인 특성을 보였다 이는 압력이 낮을수록 유도걸힘이 더 잘 된다는 것을 의미한다 1 1 mTorr에서는 H-mode에서 안테나의 전류가 파워훌 증가시킴에 따라 계속 증가하였으니, 압력이 올라 갈수록 조금씩 증가하는 정도가 줄어들고. 100mTorr에서는 포화된 값을 나타냈다 H-mode로 넘어간 후 에는 파워가 증가황에 따라 안테나의 임피던스 값이 모든 압력영역에서 줄어드는 경황을 보였고, 이는 플라즈마의 인덕턴스에 의해서 안테나의 인덕턴스 기 감소되기 때문이다, 파워가 증가할수록 안테U오} 플라즈마 루프사이의 상호걸합이 증가하는 걸로 해석힐 수 있다 안테나의 인되턴스 변화보다는 저항.성 분의 변화가 컸다 하지만 전체 임피던스로 볼 때 저항성분이 상대적으로 작기 때문에 인덕턴스의 감소 가 더 큰 영향을 미치는 걸로 볼 수 있다. 하지만 플라즈마로의 파워 전달에는 저항성분만이 영향올 미 치므로 저항성분의 큰 변화는 파워가 많이 전달될올 의미한다 피워전달 효율을 계산해 본 결과 수 r mTorr 부근이 80-90% 정도의 높은 효율올 보였고 5mTorr 일 때가 가장 좋았다.

  • PDF