• Title/Summary/Keyword: ISO Solenoid Valve

Search Result 8, Processing Time 0.032 seconds

Characteristic Analysis of Low Consumption Power ISO Solenoid Valve (저소비 전력형 ISO 솔레노이드 밸브 특성 해석)

  • Jeon, Y.S.;Ju, M.J.;Oh, Y.C.;Kim, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1250-1254
    • /
    • 2008
  • In this study, A special quality analysis and experiment for low power consumption type pneumatic ISO Solenoid valve was performed. And flow characteristics of the ISO Solenoid valve by stroke change was numerically investigated. As a result, it is shown that magnetic force(2.4N) is exerted enough to move poppet with 0.3mm stroke with 0.01 seconds of response time, and that there is no magnetic force emitted by yoke.

  • PDF

Analysis of ISO Solenoid Valve for Electrical Characteristic (ISO 솔레노이드 밸브 전기적 특성 분석)

  • Jeon, Yong-Sik;Oh, Yeong-Cheol;Ju, Min-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.663-664
    • /
    • 2008
  • In this study, A special quality analysis and experiment for low power consumption type pneumatic on-off micro valve was performed. And flow characteristics of the micro valve by stroke change was numerically investigated. As a result, it is shown that magnetic force(2.4N) is exerted enough to move poppet with 0.3mm stroke with 0.01 seconds of response time, and that there is no magnetic force emitted by yoke.

  • PDF

Influence of the tempering and magnetic annealing on soft magnetic properties for the KM35F alloy (템퍼링 및 자장열처리가 KM35F 합금의 연자성 특성에 미치는 영향)

  • Park, Byung-Ki;Jeon, Yong-Sik;Kim, Dong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1240-1243
    • /
    • 2008
  • The tempering and magnetic annealing are used to improve the soft magnetic properties such as initial permeability coercivity and core loss of the KM35F alloy. The first heat treatmentis performed at the temperature less than the curie temperature of the KM35F alloy to remove the thermal stress for few hours in nitrogen atmosphere. The second stage heat treatment is performed the magnetic annealing at $500{\sim}800^{\circ}C$ for few hours in nitrogen atmosphere, and then quenching to room temperature in absence of oxygen. Finally, magnetic properties of the thermally treated KM35F alloy are investigated for application as a soft magnetic material of the ISO solenoid valve core and plunger.

  • PDF

Generation of calibration standard gases using capillary gas divider: uncertainty measurement and method validation (다중 모세관을 이용한 교정용 표준가스의 제조: 불확도와 유효성 평가)

  • Lee, Sangyun;Hwang, Eun-Jin;Jung, Hye-Ja;Lee, Kwang-Woo;Chun, Ki-Joon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.369-375
    • /
    • 2006
  • Calibration gas mixtures were prepared using dynamic volumetric method according to ISO 6145-5 and the uncertainty was evaluated. Ten identical capillaries with 0.25 mm in inner diameter and 50 cm in length were applied in this system. Dilution ratio of parent gas was determined by the number of capillaries that passes parent gas and that passes balance gas through. Capillaries were made of Teflon which had good chemical stability against adsorption of gaseous substances. Mechanical valves were introduced in this system in order to minimize the thermal effect of solenoid valves. Concentration of prepared gases were compared with master grade standard gases in cylinders made by RiGAS Co. and calibration of the instrument were completed using comparison method according to ISO 6143. Experimental results showed that the coefficient of variance of diluted oxygen standard gases showed less then 0.2% in most dilution range, that of diluted hydrogen sulfide standard gases showed less then 1.0%. Therefore, it is proven that the standard gases prepared by this system are appropriate to be used as a calibration standards in ambient monitoring, etc.