• Title/Summary/Keyword: ISD Model

Search Result 76, Processing Time 0.026 seconds

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Validation and comparison of volume measurements using 1 multidetector computed tomography and 5 cone-beam computed tomography protocols: An in vitro study

  • Juliana Andrea Correa, Travessas;Alessandra Mendonca, dos Santos;Rodrigo Pagliarini, Buligon;Nadia Assein, Arus;Priscila Fernanda Tiecher, da Silveira;Heraldo Luis Dias, da Silveira;Mariana Boessio, Vizzotto
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.399-408
    • /
    • 2022
  • Purpose: The purpose of this study was to compare volume measurements obtained using 2 image software packages on Digital Imaging and Communications in Medicine (DICOM) images acquired from 1 multidetector computed tomography and 5 cone-beam computed tomography devices, using different protocols for physical volume measurements. Materials and Methods: Four pieces of bovine leg were prepared. Marrow was removed from 3 pieces, leaving cortical bone exposed. The resulting space of 1 piece was filled with water, another was filled with propylene glycol, and the third was left unfilled. The marrow in the fourth sample was left fully intact. Volume measurements were obtained after importing DICOM images into the Dolphin Imaging 11.95 and ITK-SNAP software programs. Data were analyzed using 3-way analysis of variance with a generalized linear model to determine the effects of voxel size, software, and content on percentage mean volume differences between tomographic protocols. A significance level of 0.05 was used. Results: The intraclass correlation coefficients for intraobserver and interobserver reliability were, respectively, 0.915 and 0.764 for the Dolphin software and 0.894 and 0.766 for the ITK-SNAP software. Three sources of statistically significant variation were identified: the interaction between software and content (P=0.001), the main effect of content (P=0.014), and the main effect of software (P=0.001). Voxel size was not associated with statistically significant differences in volume measurements. Conclusion: Both content and software influenced the accuracy of volume measurements, especially when the content had gray values similar to those of the adjacent tissues.

Development of Teaching and Learning Manual for Competency-Based Practice for Meridian & Acupuncture Points Class (역량중심 경혈학실습 교육을 위한 교수학습매뉴얼 개발 및 활용방안)

  • Eunbyul, Cho;Jiseong, Hong;Yeonkyeong, Nam;Haegue, Shin;Jae-Hyo, Kim
    • Korean Journal of Acupuncture
    • /
    • v.39 no.4
    • /
    • pp.184-190
    • /
    • 2022
  • Objectives : In our previous study, we developed the prototype of a lesson plan for meridian and acupuncture clinical skills education by applying the rapid prototyping to instructional systems design. The present study aimed to develop a teaching-learning manual, including the lesson plans, practice notes, and instructions for devices. We also aimed to present a guideline on how to use the manual in class. Methods : The manual and materials for teachers and learners were developed based on the solutions and the prototype derived from our previous study. Practical classes on meridian and acupuncture points consist of four major subjects, and the lesson plan and practice note were designed according to each topic. Results : Flipped learning, George's five-step method, peer role-play, and peer-led objective structured clinical examination (OSCE) were applied as main methodologies in the meridian and acupuncture points practical class. The teaching-learning manual, including practice notes, detailed lesson plan, OSCE checklist, and instruction manual for devices, was developed to be utilized at each stage of the learning activity. Conclusions : The application of the teaching-learning manual is expected to provide effective clinical skills education, strengthen learners' communication skills, establish professional identity, assess learners' performance, and provide immediate feedback. The educational effect of the manual for the existing class should be identified, and its feasibility should be verified by implementing it on another group. This manual could be helpful in designing classes for other subjects of Korean medicine, especially for clinical skills education.

Dental age estimation in Indonesian adults: An investigation of the maxillary canine pulp-to-tooth volume ratio using cone-beam computed tomography

  • Khamila Gayatri Anjani;Rizky Merdietio Boedi;Belly Sam;Fahmi Oscandar
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.221-227
    • /
    • 2023
  • Purpose: This study was performed to develop a linear regression model using the pulp-to-tooth volume ratio (PTVR) ratio of the maxillary canine, assessed through cone-beam computed tomography (CBCT) images, to predict chronological age (CA) in Indonesian adults. Materials and Methods: A sample of 99 maxillary canines was collected from patients between 20 and 49.99 years old. These samples were obtained from CBCT scans taken at the Universitas Padjadjaran Dental Hospital in Indonesia between 2018 and 2022. Pulp volume (PV) and tooth volume (TV) were measured using ITK-SNAP, while PTVR was calculated from the PV/TV ratio. Using RStudio, a linear regression was performed to predict CA using PTVR. Additionally, correlation and observer agreement were assessed. Results: The PTVR method demonstrated excellent reproducibility, and a significant correlation was found between the PTVR of the maxillary canine and CA(r= -0.74, P<0.01). The linear regression analysis showed an R2 of 0.58, a root mean square error of 5.85, and a mean absolute error of 4.31. Conclusion: Linear regression using the PTVR can be effectively applied to predict CA in Indonesian adults between 20 and 49.99 years of age. As models of this type can be population-specific, recalibration for each population is encouraged. Additionally, future research should explore the use of other teeth, such as molars.

Convolutional neural networks for automated tooth numbering on panoramic radiographs: A scoping review

  • Ramadhan Hardani Putra;Eha Renwi Astuti;Aga Satria Nurrachman;Dina Karimah Putri;Ahmad Badruddin Ghazali;Tjio Andrinanti Pradini;Dhinda Tiara Prabaningtyas
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.271-281
    • /
    • 2023
  • Purpose: The objective of this scoping review was to investigate the applicability and performance of various convolutional neural network (CNN) models in tooth numbering on panoramic radiographs, achieved through classification, detection, and segmentation tasks. Materials and Methods: An online search was performed of the PubMed, Science Direct, and Scopus databases. Based on the selection process, 12 studies were included in this review. Results: Eleven studies utilized a CNN model for detection tasks, 5 for classification tasks, and 3 for segmentation tasks in the context of tooth numbering on panoramic radiographs. Most of these studies revealed high performance of various CNN models in automating tooth numbering. However, several studies also highlighted limitations of CNNs, such as the presence of false positives and false negatives in identifying decayed teeth, teeth with crown prosthetics, teeth adjacent to edentulous areas, dental implants, root remnants, wisdom teeth, and root canal-treated teeth. These limitations can be overcome by ensuring both the quality and quantity of datasets, as well as optimizing the CNN architecture. Conclusion: CNNs have demonstrated high performance in automated tooth numbering on panoramic radiographs. Future development of CNN-based models for this purpose should also consider different stages of dentition, such as the primary and mixed dentition stages, as well as the presence of various tooth conditions. Ultimately, an optimized CNN architecture can serve as the foundation for an automated tooth numbering system and for further artificial intelligence research on panoramic radiographs for a variety of purposes.

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

사이버 시대의 윤리 교육 : 청소년을 중심으로

  • 류나정;고석하
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.417-424
    • /
    • 2002
  • 컴퓨터는 인간의 모든 꿈과 희망을 실현시켜 줄 수 있는 마법상자는 아니다. 정보화 시대라고 일컫는 현재, 정보의 가치를 더해주는 컴퓨터의 중요성은 날로 커지고 있는 반면 인간의 존엄성은 경시되고 있다. 많은 사람들은 요즘 사회가 커다란 도덕적 위기에 빠졌다고 걱정하지만 컴퓨터 사용과 관련된 윤리적 문제에 대해서는 심각하게 느끼지 못하고 있는 것 같다. 정보통신 기술의 발달에 따라 새로운 교육의 필요성이 대두되고 있다. 기존의 전통적인 교육방식에서 사이버 윤리 교육은 교과서 중심의 단편적인 교육이었기 때문에 학습자의 흥미를 유발하지 못하였으며, 교육자와 학습자의 상호작용이 부족하여 사이버 윤리 교육의 효과가 미흡하였다. 정보통신 기술의 발달에 따라 새로운 교육의 필요성이 대두되고 있다. 기존의 전통적인 교육방식에서 사이버 윤리 교육은 교과서 중심의 단편적인 교육이었기 때문에 학습자의 흥미를 유발하지 못하였으며, 교육자와 학습자의 상호작용이 부족하여 사이버 윤리 교육의 효과가 미흡하였다. 이런 관점에서 본 논문은 정보통신 시대가 수반하고 있는 사회적 영향력과 윤리적 이슈들에 대하여 좀더 교육적인 측면으로 접근해 윤리교육의 현황과 문제점, 그리고 체계적인 확산방안에 대해 살펴보았다. 본 논문에서는 사이버공간에서 윤리 교육을 받는 청소년들을 중심으로 그들에게 새로운 윤리교육의 한 형태인 사이버공간에서 관련된 문제들을 교육적인 측면으로 해결할 수 있는 방안을 제시하고자 한다. 그러나, 무엇보다 우리가 명심해야 할 것은 인간의 존엄성은 그 어떤 이유를 막론하고 존중되어야 한다는 사실이다. 검증되지 않은 스토리 보드에 의한 저작 단계로 바로 돌입하고 있는 것이 한국의 실정이라 하겠다. 따라서 본 프로젝트에 의해 개발 된 교수 설계 도구는 교육/학습 컨텐츠의 품질 보증을 위한 방법론인 교육 공학의 체제적 교수 설계 이론 Model (Instructional System Design Model), 특히 그 중에서도 이 분야의 사실상의 표준 이론(de facto standard)인 Dick & Carey 교수와 Gagne 교수의 인지주의 ISD Model을 기반으로 정교한 교수 설계와 코스 맵 설계를 가능하게 함으로써 학습 컨텐츠의 품질 보증 활동을 지원 할 수 있는 도구로 개발하였다. 특히 Linux 기반에서 PHP로 개발 함으로써 Platform에 구애받지 않은 사용 환경을 구현 하였으며 향후 많은 e-Learning Platform에 교수 설계 모듈로 장착 함으로써 기존의 e-Learning Platform들의 가치를 높일 수 있는 계기가 될 것으로 생각한다.실징후를 파악하는데 그치지 않고 부실의 원인을 파악하고 이에 대한 대응 전략을 수립하며 그 결과를 측정하는데 활용될 수도 있다. 따라서 본 연구에서는 기업의 부도예측 정보 중 현금흐름정보를 통하여 '인터넷기업의 미래 현금흐름측정, 부도예측신호효과, 부실원인파악, 비즈니스 모델의 성격규정 등을 할 수 있는가'를 검증하려고 한다. 협력체계 확립, ${\circled}3$ 전문인력 확보 및 인력구성 조정, 그리고 ${\circled}4$ 방문보건사업의 강화 등이다., 대사(代謝)와 관계(

  • PDF

Developing a Customized Sexually Transmitted Infections (STIs) Smartphone Application for Adolescents: An Application of the Instructional System Design Model (청소년 성매개 감염병 교육을 위한 스마트폰 어플리케이션 개발과정)

  • Jeong, Soo-Kyung;Cha, Chi-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.651-659
    • /
    • 2017
  • Although the need for education on sexually-transmitted-infections (STIs) for adolescents has been increasing, a limited number of adolescents receive STI education. Importantly, the exposure of youth to an STI during their adolescence period can seriously affect their genital health. Smartphones are an innovative medium that can be used to change individual behaviors, especially useful when used to educate adolescents. Therefore, we developed a customized smartphone application for Korean adolescents. The application was based on Dick and Carey's instructional system design model. In this paper, we describe the process for development of the smartphone application, and the strategies we applied to attract adolescents to use the smartphone application. Six experts verified the educational content of the application. The application's easygoing words were chosen to help adolescents understand the topic. Strategies such as cartoon clips, secret chat rooms, buttons changing color from blue to grey, questions and answers, and a repeated-learning function were used to attract Korean adolescents to the application. The smartphone application developed in this study could be used in schools, youth centers, and hospital centers to improve STI knowledge, STI prevention, and STI coping skills.

Intravenous contrast media application using cone-beam computed tomography in a rabbit model

  • Kim, Min-Sung;Kim, Bok-Yeol;Choi, Hwa-Young;Choi, Yoon-Joo;Oh, Song-Hee;Kang, Ju-Hee;Lee, Sae-Rom;Kang, Ju-Han;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.31-39
    • /
    • 2015
  • Purpose: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. Materials and Methods: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. Results: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Conclusion: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

  • Pittayapat, Pisha;Jacobs, Reinhilde;Odri, Guillaume A.;Vasconcelos, Karla De Faria;Willems, Guy;Olszewski, Raphael
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.15-22
    • /
    • 2015
  • Purpose: This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Materials and Methods: Thirty-two cone-beam computed tomographic scans (3D Accuitomo$^{(R)}$ 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim$^{(R)}$ software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). Results: The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from $0.43{\pm}0.34mm$ to $0.51{\pm}0.46mm$. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. Conclusion: A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.