Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
The Korean Journal of Nuclear Medicine Technology
/
v.23
no.1
/
pp.35-39
/
2019
Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).
Purpose: $TFB^{(R)}$ CA19-9 IRMA kit uses beads coated with CA19-9 antibody. However, this mathod can not use automated equipment, and requires a long time test. Recently, CA19-9 IRMA kit developed by $TFB^{(R)}$ is coated with CA19-9 antibody to the polystyrene test tube and reaction at room temperature, and also reduced test time. This study evaluated the performance of a newly developed $TFB^{(R)}$ CA19-9 IRMA kit. Materials and Methods: This study were measured by using 56 patients sample of Boramae Medical Center and Seoul National University Hospital. We evaluated intra-and inter-assay precision, recovery rate, linearity, sensitivity and high dose hook effect of coated tube CA19-9 IRMA kit developed by $TFB^{(R)}$. The values of CA19-9 measured by $TFB^{(R)}$ bead kit were compared with those measured by $TFB^{(R)}$ coated tube kit. Results: ntra-assay coefficients of variation on three different levels were 4.1%, 4.0% and 4.2%. Inter-assay coefficients of variation were 7.6%, 4.3% and 7.8%. Recovery tests on all three different levels showed within $100{\pm}10%$. Linearity was good and sensitivity was 0.3 U/mL. High dose hook effect is not observed. There was strong correlation between bead kit and coated tube kit by $TFB^{(R)}$ CA19-9 IRMA kit. (y=0.9185x-0.953, $R^2$=0.9779) Conclusion: Coated tube CA19-9 IRMA kit developed by $TFB^{(R)}$ showed satisfactory precision, recovery rate, linearity, sensitivity and high dose hook effect.
Purpose The principle of nuclear medicine test is divided into two main categories: competition(radioimmunoassay, RIA) and noncompetitive reaction(Immunoradiometric assay, IRMA). It is known that the curve fitting method, which is commonly used in inspection field, uses Spline interpolation in RIA method and Linear interpolation method in IRMA method. Among them, the insulin test using the IRMA test showed a significant difference, especially at low concentrations, despite the same algorithm of linear interpolation between fully automated radio immunoassay analyzers. In this study, we aim to obtain results from applying two different of algorithm using fully automated radio immunoassay analyzers including Gamma pro, Gamma 10, Cobra, and SR300. Materials and Methods A total of 30 test samples were selected for the test of TSH, ferritin, C-peptide, and insulin serum levels. Test was performed by IRMA method. We compared the difference in the results of applying the linear interpolation method and the spline interpolation method to Gamma Pro, Gamma 10, Cobra, and SR300 equipment. Results Two-way ANOVA was used for statistical analysis. The significance level was applied as P <0.05. The results of TSH, ferritin, C-peptide, and insulin tests were compared between the fully automated radio immunoassay analyzers. There was a significant difference between ferritin, C-peptide, and insulin serum levels(P<0.001). TSH didn't show any significant different between the devices(P=0.29). In the difference between linear and spline interpolation, there was no significant difference between insulin test(P=0.08), TSH test(P=0.81), and Ferritin test(P=0.06). However, C-peptide test showed a significant difference(P=0.03). Especially, the insulin test showed significant difference in lower ranges. As a result of comparing and analyzing the difference between the two interpolation methods, the devices in the low concentration group showed significant difference(P<0.001). Conclusion In case of new equipment in the laboratory it is necessary to recognize that there is a difference in the curve fitting method for each automated radio immunoassay analyzers in the low concentration area when the principle of inspection is IRMA method.
The Purpose of this study is development and analysis of Effluence Characteristic of the Rainfall in the IRMA Green Roof System(developed in KICT) Plus 50 program is an internal research project at KICT(Korean Institute of Construction Technology) which has it as an object ; to lengthen the building's life 50-year or more and reduce energy conception 50% than present. Green roof system is one of the most important theme in the Plus 50 program. Generally, a Green Roof System has a positive effect on the thermal conductivity in winter, the micro cooling effect on building and city by evaporation in summer, the flood-control effect by runoff-reduction or the treated rainwater-quality of green roof system and so on. However, inspection of the physical effect of green roof system does not consider in Korea. Above all, long-term monitoring and a whole observation of green roof system is needed to probate the effect. So a new experimental method could be tried in this research, which is never attempted in Korea. The measurement by a bucket with a great volume, 1L, gives a new dimension of measuring green roof effect to measure the permanent running flood from a wide roof. This offers a reasonable result on a long-term measuring of a running water. Additionally, the thermal behavior of the IRMA(Insulated Roof Membrane Assembly), known in the western europe as a reasonable solution at green roof system by economical benefits and easy construction, would be experimented.
Ha, Dong-Hyuk;Min, Kyung-Sun;Noh, Gyeong-Woon;Kim, Hyun-Ju
The Korean Journal of Nuclear Medicine Technology
/
v.15
no.1
/
pp.121-125
/
2011
Purpose: The DNA-type virus HBV, discovered by D. Dane and others in 1976, is approximately 42nm big and known as the main cause of liver-related diseases around the world. HBsAg has 4 kinds of subtypes including adw, adr, ayw and ayr and besides common antigen factor a, there are d, y, r, w. From the methods of serologically testing HBV, IRMA, EIA and CLIa were developed for testing HBsAg and are being used in examining the surface antigen of HBV. In this study, among the methods for testing HBV, the recently developed RIAKEY Ultrasensitive HBsAg IRMA kit's sensitivity level and performance in detection of mutant forms were measured and compared with CLIA. Materials and methods: Two certified reference materials, which are WHO 1st International Standard 1985(80/549) and WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA), were used in the examination and the sensitivity level was measured by diluting these materials from 0.08 IU/ml to 0.005 IU/ml. The materials for examining the detection of mutant forms included 9 kinds of subtype 'ad' and one kind of subtype 'ay' purchased from DSI company. Also, with the use of positive and negative samples, they was compared with CLIA. Result: Ultrasensitive HBsAg kit based on IRMA method showed the detection of up to 0.01 IU/ml not only for WHO 1st International Standard 1985(80/549) but also for WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA) and the sensitivity level was measured as 0.01 IU/ml by WHO standard. In testing the performance for detection of mutant forms, the 9 kinds of subtype 'ad' and one kind of subtype 'ay' mutant materials were detected, demonstrating the capacity of detecting various types of mutant forms. Conclusions: With the clinical importance of sensitivity level and performance in detection of mutant forms increasing in the field of HBsAg diagnosis, the examination of IRMA's effectiveness using RIA method in the aspects of the sensitivity level and performance in detection of mutant forms was carried out and its result is as follows. The sensitivity level was measured as 0.01 IU/ml by WHO standard and it was possible to measure various types of mutant forms with high sensitivity. Thus it is suggested that more speedy and accurate reports could be produced from a nuclear medicine laboratory for clinical practitioners requiring results of various situations.
Purpose : IRMA method for the experimental reagents, as set out in the manual settings for doing and reporting the test results should, in principle. But many of the reagents allows for the setting of the plot does not have a lot of information. Depending on the angle setting of the table make a difference in test results and what settings are best suited to investigate. Materials and Methods : The hospital has Boramae DREAM10, Cobra, SR-300's using the Immunotech TSH reagents have been compared with the measurements. Since then there using EXCEL calculation of the equipment compared with the measurement. Results : In the comparison between each piece of equipment 1.SR-300: DREAM 10 y = 1.1376x - 0.046 (LOG-LOGIT), 2.SR-300: COBRA y = 1.0985x + 0.042 (LOG-LOG) 3.DREAM10: COBRA y = 0.965x + 0.0887 (LOG-LOG) was the result. In all charts the same X, Y axis, X values were good in general when you have. Linear-Logit value of Cobra Dream10 and Excel tends to match the calculated values provided. Conclusion : Is to guide the B / max, B / Total Logit Y axis of the chart is set to draw a look at the value equation when the X-axis LOG a high concentration are disadvantages rising urgently toward the slope. Linear-Logit plots close to the straight line has a curve. If you have a chart to guide on setting AS setting and therefore, set to guide the absence of information on the need to set up the experiment are thought to pass through.
Purpose: Although ${\alpha}$-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for ${\alpha}$-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for ${\alpha}$-fetoprotein (Riakey AFP IRMA $CT^R$, Sin-Jin Medics, Seoul, Korea). Materials and Methods: We evaluated intra- and inter-assay precision, recovery rate, parallelism, and sensitivity of serum ${\alpha}$-fetoprotein measurement using Riakey AFP IRMA $CT^R$ kit. The values of ${\alpha}$-fetoprotein measured by Riakey AFP IRMA $CT^R$ kit were compared with those measured by two foreign commercial kits (${\alpha}$-fetoproteina of Radim and ${\alpha}$-feto.riabead of Abbott). Results: Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within $100{\pm}10%$. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of ${\alpha}$-fetoprotein by Riakey AFP IRMA $CT^R$ and that by two foreign commercial kits(r=0.98). Conclusion: The first Korean domestic immunoradiometric kit for ${\alpha}$-fetoprotein, Riakey AFP IRMA $CT^R$, performed well for clinical use.
To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit $(Abott^{(R)}\;and\;Daichi^{(R)})$. Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 voluteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intra assay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/l respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU/l. Mean recoveray rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/l and 2.85-30.8 mU/l repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function.
The soluble transferrin receptor(TfR) in human serum has been shown recently to be a truncated form of intact membrane bound receptor containing most of the extracellular domain. We purfied the transferin-free TfR from human serum by immounoaffinity chromatography which produced the single protein identity in high resolution gel chormatography. The monoclonal antibodies(MAb) against purifed serum TfR were produced by fusion of spleen cells o fimmunized Balb/c mice and SP2 cells. Ten hybrids producing MAb specific for serum TfR were identifed and determine their iostypes. A immunoraddiometric assay (IRMA) for serum TfR was established using two monoclonal IgG1 antibodies as the coating and indicator antibodies on the bosis of their suitability in sandwich IRMA of serum TfR. The mean serum TfR levels in the 15 normal male, 15 normal female, and 19 iron-deficient subjects were 5.4$\pm$0.98, 4.6$\pm$0/76, and 18.0$\pm$12.8mg/1, respectively, and the difference in mean values between normal and iron deficient subjects was significant(p=0.0005). There existed the inverse logarithmic relationship(r=-0.9336, p<0.0001) between the serum TfR and ferritin levels.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.