• 제목/요약/키워드: IPS Empress ceramic

검색결과 76건 처리시간 0.03초

Investigations on the effects of mouthrinses on the colour stability and surface roughness of different dental bioceramics

  • Soygun, Koray;Varol, Osman;Ozer, Ali;Bolayir, Giray
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.200-207
    • /
    • 2017
  • PURPOSE. In this study, three bioceramic materials, [IPS Empress CAD (Ivoclar), IPS e.max CAD (Ivoclar), and Lava Ultimate CAD (3M ESPE)] were treated with three commercial mouthrinses [Listerine, Tantum Verde, and Klorhex]; and changes in colour reflectance and surface roughness values were then quantitatively assessed. MATERIALS AND METHODS. One hundred and twenty ceramic samples, with dimensions of $2{\times}12{\times}14mm$, were prepared and divided into nine sample groups, except three control samples. The samples were immersed in the mouthrinse solutions for 120 hrs, and changes in colour reflectance and surface roughness values were measured by UV light spectrophotometry (Vita Easyshade; VITA Zahnfabrik) and by profilometer device (MitutoyoSurftest SJ-301), respectively. The change of surface roughness was inspected by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). RESULTS. There was a positive correlation between the ${\Delta}E$ and increase in the surface roughness. Two of the ceramic materials, IPS Empress and Lava Ultimate, were affected significantly by the treatment of the mouthrinse solutions (P<.05). The most affecting solution was Tantum Verde and the most affected material was Lava Ultimate. As expected, the most resistant material to ${\Delta}E$ and chemical corrosion was IPS e max CAD among the materials used. CONCLUSION. This work implied that mouthrinse with lower alcohol content had less deteriorating effect on colour and on the surface morphology of the bioceramic materials.

Empress 2 도재와 레진시멘트의 결합강도에 관한 연구 (A STUDY ON THE BOND STRENGTH OF RESIN CEMENTS TO EMPRESS 2 CERAMIC)

  • 김정숙;황희성;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.184-196
    • /
    • 2001
  • The objective of this study was to investigate the influence of resin cements and ceramic etching on shear bond strength of Empress 2 ceramic and observe the change of microstructure of ceramic according to etching time. Sixty-six square ceramic specimens($6{\times}6{\times}1.5mm$) were prepared. 6 specimens were etched with different etching times(0, 10, 20, 30, 40 and 60 seconds) and observed by means of a scanning electron microscope(SEM). Other sixty specimens were divided into 6 groups with 10 specimens in each group. 3 groups were etched with 4% hydrofluoric acid and each groups was bonded with 3 resin cements(Variolink II, Super-Bond C&B, Panavia F). Each specimen was subjected to a shear load in an Instron at a cross-head speed of 0.5mm/min and was observed with SEM after mechanical testing to establish modes of failure. The results were as follows : 1. Within etched groups, Variolink II and Super-Bond C&B exhibited significantly greater bonding strengths than Panavia F(p<0.05) 2. Bond strength of etching groups had three to five times greater than that of no-etching groups. 3. All of no-etching groups showed adhesive failure and etching groups mostly showed mixed failure. And, 20-second etching specimen showed the most distinct lithium disilicate crystal. so it is considered that 20-second etching is optimal time for bonding.

  • PDF

임시접착 후, 치면세마에 따른 Lithium Disilicate Glass-Ceramic의 레진결합강도에 대한 연구 (Resin Bond Strength of Lithium Disilicate Glass-Ceramic by Surface Cleansing Method after Temporary Cementation)

  • 정승화;이진한;오상천
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.259-268
    • /
    • 2007
  • purpose: This study was to evaluate the shear bond strength of Lithium Disilicate Glass-Ceramic by removable method of temporary cement on the abutment tooth. Material and Method: Sixty molar teeth of human with the occlusal surface up were mounted in acrylic resin blocks. The 45 specimens were prepared to exposure dentin by diamond bur and the eugenol-containing temporary cement($Cavitec^{TM}$ ($KERR^{(R)}$, U.S.A)was applied to the dentin surfaces. After initial removal of the cement with a dental explorer, the specimens were divided into 4 groups of 15 specimens each. The dentin surfaces of the specimens were treated by rotary instrument with as follow pastes: $Zircate^{(R)}$ prophy paste(Dentsply, U.S.A), Radent Prophy Paste(Pascal company,inc. U.S.A), and Dental pumice(Wip mix corporation,U.S.A). An adhesive resin luting agent(Variolink $II^{(R)}$, Ivoclar Vivadent, Leichtenstein) including Monobond-S and $Excite^{(R)}$ was applied to all specimens. The ceramic specimens were made with an A1 ingot of IPS Empress $II^{(R)}$ (Ivoclar Vivadent, Leichtenstein). After the specimens were stored in distilled water for 48hr, the shear bond strength(MPa) was measured by a Universal testing machine(Zwick 145641, Zwick, Germany) at a 1mm/min cross-head speed. The data were statistically analyzed by one-way ANOVA and Duncan's multiple range test. Results: In all group, there were no significant differences in comparison with the control group(p>0.05). The pattern of most failure showed the mixed type of cohesive and adhesive failure. Conclusion: Resin bond strength of IPS Empress $II^{(R)}$ was not affected by removal method of the temporary cement.

상악 제1소구치에서 전부도재관의 finish line 형태에 따른 파절강도와 응력 분포에 관한 연구 (Fracture Resistance and Stress Distribution of All Ceramic Crowns with Two Types of Finish Line on Maxillary First Premolar)

  • 이상권;동진근
    • 구강회복응용과학지
    • /
    • 제19권3호
    • /
    • pp.219-237
    • /
    • 2003
  • he purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown, and 0.5mm width chamfer finish lines on the maxillary first premolar. 30 sound maxillary first premolars were selected and then storaged in 5% NaOCl and saline. 15 teeth were performed preparation for each group(1.0mm rounded shoulder, 0.5mm chamfer). After 30 stone dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the natural teeth. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co., Germany)was used to measure the fracture strength, with stress loading on the occlusal surface between buccal and lingual cusp. And also, three-dimensional finite element model was used to measure the stress distribution with two types of the finish lines(1.0mm rounded shoulder, 0.5mm chamfer) and two loading conditions(both buccal and lingual cusp inclination, lingual cusp inclination only). The result of the this study were as follows. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(842N) showed higher value than that of the chamfer(590N) (p<0.05). In the three dimensional finite element analysis of all ceramic crown, metal die and natural teeth model did not show any differences in stress distribution between finish lines. Generally, when force was loaded on the occlusal inclination of buccal and lingual cusp, the stress was concentrated on the loading point and the central groove of occlusal surface. When force was loaded only on the occlusal inclination of lingual cusp, the stress was concentrated on the lingual finish line and loading point.

캐드캠 세라믹의 코어와 베니어의 서로 다른 두께가 반투명도에 미치는 영향 (Effect of translucency on CAD/CAM ceramic according to different core/veneer thickness)

  • 강월;김지환
    • 한국치위생학회지
    • /
    • 제18권6호
    • /
    • pp.1037-1045
    • /
    • 2018
  • Objectives: The purpose of this study was to evaluation the effect of translucency on CAD/CAM ceramic according to different core/veneer thicknesses. Methods: A total of 42 samples from 2 groups of 7 ceramic cores, each with 3 thickness values (0.8, 1.0, 1.2 mm) were manufactured. The veneers were also manufactured in 3 thicknesses (0.3, 0.5, 0.7 mm). The group names were based on the name of the ceramic core (IPS e.Max CAD; LD, and IPS Empress CAD; LR). The associated number was determined by the combined thickness of the core and veneer: 1 = (0.8 + 0.7); 2 = (1.0 + 0.5); 3 = (1.2 + 0.3). The translucency was measured using a spectrophotometer and defined via the contrast ratio (CR) and translucency parameter (TP). Two-way ANOVA was performed to compare the 2 groups (material and thickness). Results: As the core thickness increased, the TP value also increased, and the CR value (for LR group) decreased. The results of 2-way ANOVA demonstrated that the thicknesses of different core/veneer combinations significantly affected the translucency (p<0.05). Conclusions: The different core and veneer thicknesses affected the translucency of CAD/CAM ceramic.

수 종의 도재 수복물에 부착된 세라믹 브라켓의 전단접착강도와 파절양상에 열순환이 미치는 영향 (Effect of thermocycling on shear bond strength and mode of failure of ceramic orthodontic brackets bonded to different porcelain restorations)

  • 강상욱;손우성;박수병;김성식
    • 대한치과교정학회지
    • /
    • 제39권4호
    • /
    • pp.225-233
    • /
    • 2009
  • 본 연구는 도재 수복물에 부착된 단결정 세라믹 브라켓의 전단접착강도와 파절양상에 열순환과 도재 수복물의 종류가 어떤 영향을 미치는지 알아보기 위해 시행되었다. 도재전장관에 사용되는 재료들 중 Ceramco 3, Empress II, Zi-ceram/Vintage ZR 세 가지를 선택하여 각 20개씩 총 60개의 시편을 원반형태(두께 2 mm, 직경 12 mm)로 제작하였다. 동일한 접착 술식으로 세라믹 브라켓을 부착한 후 열순환을 시행한 실험군과 시행하지 않은 대조군, 두 군으로 나누어 전단접착강도와 파절양상을 평가하였다. 열순환을 하지 않은 대조군의 전단접착강도는 Ceramco 3는 $7.06\;{\pm}\;1.76\;MPa$, Empress II는 $7.55\;{\pm}\;2.38\;MPa$ 그리고 Zi-ceram/Vintage ZR은 $7.19\;{\pm}\;1.38\;MPa$로 추천되는 전단접착 강도(6 - 8 MPa)에 적합한 강도를 보였으나 열순환을 시행한 실험군은 전단접착강도가 유의하게 감소하였으며(p < 0.05) 열순환 후의 전단접착강도는 Ceramco 3는 $4.88\;{\pm}\;1.00\;MPa$, Empress II는 $5.46\;{\pm}\;1.35\;MPa$ 그리고 Zi-ceram/Vintage ZR은 $4.84\;{\pm}\;1.01\;MPa$로 임상적으로 추천되는 것보다 다소 낮은 값을 보였다. 도재의 종류에 따른 전단접착강도에는 유의한 차이가 없었다. 파절양상은 대조군에서는 모두 브라켓 기저부와 접착제 사이에서 파절이 일어났으며, 실험군에서는 2개의 시편(Ceramco 3과 Zi-ceram/Vintage ZR군에서 각 1개)만이 접착제내 파절을 보였으며 28개의 시편은 브라켓 기저부와 접착제 사이에서 파절이 일어났다. 이상의 연구 결과에서 보았을 때 도재 수복물의 종류에 따른 차이는 없었으나 열순환에 의해 전단접착강도가 약화되므로 실제 임상에서 고려되어야 할 것이다.

Evaluation of the fracture resistance of all-ceramic zirconia posts by 3 different methods

  • Jeong, Seung-Mi;Chung, Chae-Heon;Kang, Dong-Wan;Ludwig, Klaus;Kern, Matthias;Huels, Alfons
    • 대한치과보철학회지
    • /
    • 제38권6호
    • /
    • pp.757-764
    • /
    • 2000
  • Statement of the problem. All-ceramic post-and-core restorations offer a number of advantages compared with systems that use metal build-ups. In certain clinical cases, however, fractures at the joint between the post and core build-up have been reported. Purpose. The objective, therefore, is to improve the joint between the post and the core build-up. Material and methods. Three different methods were used to prepare all-ceramic post-and-core restorations; pressing IPS Empress core build-ups to CosmoPost zirconia posts, cement-ing IPS Empress core build-ups to CosmoPost zirconia posts and Celay-milling of zirconia blanks. A series of ten restorations was prepared for each of the three methods. The post-and-core complexes were tested to failure with the load applied perpendicular to the post axis. The load and deflection at fracture were recorded. Results. The highest breaking load and highest deflection were recorded for the cementing technique with values of 25.3 N and $394{\mu}m$, respectively, The corresponding values for the pressed core build-ups and the milled zirconia core build-ups were 22 N and $301{\mu}m$, and 13 N and $160{\mu}m$, respectively. All the differences are statistically significant (p=0.05). Regarding the load-dependence of the deflection, the cemented core build-ups again demonstrated the highest value with $15.5{\mu}m/N$. The difference in the values of $13.6{\mu}m/N\;and\;13{\mu}m/N$ recorded for the pressed-on and milled core build-ups, respectively, were statistically insignificant. Conclusion. In regard to the high fracture resistance of zirconia post, adhesive cementing the core build-up to the post offers a viable alternative to the conventional pressing technique. The elastic bond between the rigid high-strength zirconia post and the core build-up presents an additional advantage.

  • PDF

전부도재관용 도재의 염색 저항성에 관한 연구 (A STUDY ON THE STAIN RESISTANCE OF DENIAL CERAMICS FOR ALL CERAMIC CROWN)

  • 손외수;진태호
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.416-424
    • /
    • 1999
  • Simulation of naturally appearing enamel in fixed prosthodontics could be achieved with all ceramics. The purpose of this study was to investigate the stain resistance of 4 different all ceramics materials (In-ceram, IPS Empress, Celay, Vintage). Forty specimens were prepared using manifacture's instruction and the samples were divided into two groups. The specimens for one group were glazing and those for other group were ground to remove the glazing layer. All specimens were immersed in methylene-blue for 24hours. The color values for each specimen was measured with colorimeter (Mode Tc-6Fx, Tokyo Denshoku Co.) prior to and after immersion in methylene-blue. The following conclusions were drawn from this study. 1 The stain resistance of glazing ceramics was higher than that of unglazing ceramics. 2. The changes of ${\Delta}E^*$\;and\;L^*$ values were revealed in Vintage and unglazing Celay. 3. The changes of $a^*$ values were revealed in unglazing vintage, Celay, In-ceram. 4. The changes of $b^*$ value were revealed in Vintage, IPS Empress and unglazing Celay.

  • PDF

치아 부위에 따른 지르코니아 도재관의 파절강도 (Fracture strength of zirconia ceramic crowns according to tooth position)

  • 이인섭;김정미;동진근
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.94-100
    • /
    • 2010
  • 연구목적: 본 연구는 상악과 하악의 각 치아부위에 $Lava^{TM}$ All-Ceramic System을 이용하여 지르코니아 전부도재관을 제작하고 각각의 파절강도를 알아보고자 하였다. 연구방법:중절치와 견치는 절단연의 삭제량을 2.0 mm, 소구치와 대구치는 교합면의 삭제량을 1.5 mm, 그리고 축면 경사도는 $8^{\circ}$로하여모두8군의 실험군을 설정하였다. 금속 다이와 지르코니아 도재관을 제작한 후 레진시멘트 (Rely $X^{TM}$ Unicem)를 이용하여 합착하고 만능시험기상에서 치아 장축에 $30^{\circ}$경사지게 하여 중절치와 견치에 제작된 지르코니아 도재관은 절단연 중앙 부위에 하중을 가하였고, 소구치와 대구치에 제작된 지르코니아 도재관은 기능교두의 협설측 경사면 중앙부위에 하중이 가해지도록 한 후 파절강도를 측정하였다. 결과:1. 지르코니아 도재관의 평균 파절강도는 하악 제1대구치에서 2963 N으로 가장 높게 나타났으며, 하악 중절치에서 1035 N으로 가장 낮게 나타났다. 2. 지르코니아 도재관과 IPS Empress 도재관과의 평균 파절강도는 모든 치아에서 지르코니아 도재관이 더 크게 나타났다. 3. 지르코니아 도재관의 파절 양상은 하중이 가해진 중앙 부위에서 치아 장축으로 수직적인 파절상을 보였다. 4. 상악과 하악의 동일 부위에 제작된 지르코니아 도재관의 파절강도는 소구치에서 상악이 하악에 비하여 낮은 것으로 나타났으며 (P< .05), 다른 부위에서는 유의한 차이가 없었다 (P> .05). 결론: 본 실험의 결과로 지르코니아 도재관은 임상에서 활용하기에 만족할 만한 강도를 갖고 있음을 알 수 있었다.

상아질 지각완화제가 레진시멘트의 전단결합강도에 미치는 영향 (EFFECT OF DENTIN DESENSITIZERS ON SHEAR BOND STRENGTH OF RESIN CEMENTS)

  • 이호;진태호;손외수;안희영
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.365-373
    • /
    • 2002
  • The purpose of this study was to investigate the effects of desensitizer on shear bond strength of adhesive resin cements for all ceramic crown. For this study, Gluma $desensitizer^{(R)}$(Heraeus Kulzer, Germany) and MS $Coat^{(R)}$(Sun medical, Japan) were used as desensitizer, and Bistite $II^{(R)}$ resin cement(Tokuyama, Japan) and Variolink $II^{(R)}$ resin cement (Ivoclar, Liechtenstein) were used. IPS Empress ceramics were bonded to dentin surfaces after application of desensitizer and shear bond strength of specimens were measured using UTM(Zwick 1456 41. Zwick, Germany) at a crosshead speed of 1mm/min. The obtained results were as follows : 1. The shear bond strength of both resin cements were not affected by Gluma $desensitizer^{(R)}$ containing HEMA 2. The shear bond strength of Bistite $II^{(R)}$ resin cement was significantly decreased by MS $Coat^{(R)}$. 3. The failure mode in MS $Coat^{(R)}-Bistite \;II^{(R)}$ group was mainly adhesive type between dentin and resin cement. but that of Gluma $desensitizer^{(R)}$-Variolink $II^{(R)}$ group was mainly mixed type, combined adhesive failures between dentin and resin cement or porcelain and resin cement.