• 제목/요약/키워드: IMPLANT

검색결과 6,058건 처리시간 0.032초

A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis

  • Song, Ho-Yong;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.304-312
    • /
    • 2016
  • PURPOSE. The aim of this study was to investigate the stress distribution of 2-short implants (2SIs) installed in a severely atrophic maxillary molar site. MATERIALS AND METHODS. Three different diameters of internal connection implants were modeled: narrow platform (NP), regular platform (RP), and wide platform (WP). The maxillary first molars were restored with one implant or two short implants. Three 2SI models (NP-oblique, NP-vertical, and NP-horizontal) and four single implant models (RP and WP in a centered or cantilevered position) were used. Axial and oblique loadings were applied on the occlusal surface of the crown. The von Mises stress values were measured at the bone-implant, peri-implant bone, and implant/abutment complex. RESULTS. The highest stress distribution at the bone-implant interface and the peri-implant bone was noticed in the RP group, and the lowest stress distribution was observed in the 2SI groups. Cantilevered position showed unfavorable stress distribution with axial loading. 2SI types did not affect the stress distribution in oblique loading. The number and installation positions of the implant, rather than the bone level, influenced the stress distribution of 2SIs. The implant/abutment complex of WP presented the highest stress concentration while that of 2SIs showed the lowest stress concentration. CONCLUSION. 2SIs may be useful for achieving stable stress distribution on the surrounding bone and implant-abutment complex in the atrophic posterior maxilla.

나사풀림과 나사파절이 동반된 실패한 임플란트 고정성 보철물의 회복증례 (Reconstruction of failed fixed implant prosthesis accompanied by abutment screw loosening and fracture : A case report)

  • 배은빈;신영근;전영찬;정창모;윤미정;이소현;허중보
    • 대한치과의사협회지
    • /
    • 제55권7호
    • /
    • pp.457-466
    • /
    • 2017
  • In the case of failed fixed implant prosthesis accompanied by abutment screw fracture, fractured screw fragment must be removed to use the existing implant fixtures. A 61-year-old male patient, who had a failed maxillary fixed implant prosthesis accompanied by three abutment screw fracture, hoped to reconstruct the maxillary implant prosthesis, while maintaining the existing implant fixtures. To use the existing implant fixtures, fractured screw fragments were removed. A maxillary implant overdenture using available existing implants was planned. Bar-attachment with Locator was used for implant splinting, denture stability, and retention. Final impression was taken after treatment of peri-implantitis. Jaw relation registration was taken to evaluate available interarch space for bar-attachment. After fabricating bar-attachment, centric relation was taken. Implant overdenture using bar-attachment with Locator was delivered after wax-denture evaluation. This case report showed that a satisfactory clinical result was achieved by implant overdenture using existing implant fixtures in a maxillary edentulous patient.

  • PDF

A comparison of the implant stability among various implant systems: clinical study

  • Kim, Jae-Min;Kim, Sun-Jong;Han, In-Ho;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.31-36
    • /
    • 2009
  • PURPOSE. To determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period(24 weeks), without loading. MATERIAL AND METHODS. Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems(group A,C,R) were placed in the posterior maxilla or mandible. The specific transducer for each implant system was used. ISQ(implant stability quotient) reading were obtained for each implant at the time of surgery, 3, 6, 8, 10, 12, 24 weeks postoperatively. Data were analyzed for different implant type, bone type, healing time, anatomical locations. RESULTS. For each implant system, a two-factor mixed-model ANOVA demonstrated that a significant effect on ISQ values(group A=0.0022, C=0.017, R=0.0018). For each implant system, in a two-factor mixed model ANOVA, and two-sample t-test, the main effect of jaw position(P > .005) on ISQ values were not significant. CONCLUSIONS. All the implant groups A, C and R, the change patterns of ISQ over time differed by bone type. Implant stability increased greatly between week 0 and week six and showed slow increase between week six and six months(plateau effect).

Cp-Ti와 Ti-6Al-4V 합금으로 제조된 치과용 임플란트의 부식특성에 관한 블라스팅과 산세처리의 영향 (Effects of Blasting and Acidic Treatment on the Corrosion Characteristics of Dental Implant Fabricated with Cp-Ti and Ti-6Al-4V Alloy)

  • 문영필;최한철;박수정;김원기;고영무
    • 한국표면공학회지
    • /
    • 제39권4호
    • /
    • pp.190-197
    • /
    • 2006
  • The effects of blasting and acidic treatment on the corrosion characteristics of dental implant fabricated with Cp-Ti and Ti-6Al-4V alloy have been researched by using electrochemical methods. The fabricated implants were cleaned and sandblasted by $Al_2O_3$ powder and then acidic treatment was carried out in nitric acid solution. The surface morphology were observed using scanning electron microscope. The corrosion behaviors were investigated using potentiosat and EIS in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The potentio-dynamic test in 0.9% NaCl indicated that the corrosion potential of blasting and acidic treated implant was lower than that of non treated implant, but current density was higher than that of non treated implant. From the cyclic potentiodynamic test results of Ti implant, the passivation current density of blasting and acidic treated implant slightly higher than that of non treated implant. From A.C. impedance test results in 0.9% NaCl solution, polarization resistance($R_p$) value of blasting and acidic treated implant was lower than that of non treated implant. In case of blasting and acidic treated implant surface, the pits were observed in valley and crest of implant surface.

DENTIS 내부연결형 서브머지드 임플란트에서 지대주 선택에 따른 성공률의 후향적 연구 (A retrospective randomized study of success rates according to abutment selection in DENTIS submerged implant with an internal hex connection)

  • 김은희;이정은;황희성;김철훈;김정한;김복주
    • 대한치과의사협회지
    • /
    • 제56권11호
    • /
    • pp.605-614
    • /
    • 2018
  • PURPOSE. The purpose of this study is to determine the efficacy of the DENTIS submerged-type implant with an internal hex connection and to build corresponding abutment-selection criteria. MATERIAL AND METHODS. A total of 204 patients received submerged implant fixtures with an internal hex connection at the Dong-A University Hospital Dental clinic in Busan from January 2013 and May 2016. Three specific abutments, UCLA abutments, customized abutments, ready-made abutments, were randomly selected. Implant success was defined as the basis of the International Congress of Oral Implantologists(ICOI, 2007) criteria. The relationship between the implant success rate and the abutment factor was analyzed using the Kruskal-Wallis test(P<.05). RESULTS. A total of 508 implants were placed in 204 patients. After a mean observation period of 38.6 months, 493 out of 508 implants were in normal function, yielding an overall success rate of 97.05%. A total of 15 implants failed: 10 in the maxillary molar area, 4 in the mandibular molar area, and 1 in the mandibular incisal area. All of the implant failures occurred in a single-implant prosthesis, especially high in the maxillary molar area. The Kruskal-Wallis analysis showed that abutment selection has no significant correlation with implant failure(P>.05). CONCLUSION. DENTIS submerged implants with an internal hex connection showed predictable results with a success rate of 97.05%. It is no influence on the success rate in the selection of submerged implant abutment with an internal hex connection.

  • PDF

Effect of repeated use of an implant handpiece on an output torque: An in-vitro study

  • Son, KeunBaDa;Son, Young-Tak;Kim, Ji-Young;Lee, Jae-Mok;Yu, Won-Jae;Kim, Jin-Wook;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.136-143
    • /
    • 2021
  • Purpose. This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque. Materials and Methods. Two types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150). For statistical analysis, the difference between the groups was analyzed using the Mann-Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05). Results. NSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (P<.001). The type of implant handpiece and repeated use influenced the output torque (P<.001). Conclusion. There may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.

Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study

  • Acharya, Paramba Hitendrabhai;Patel, Vilas Valjibhai;Duseja, Sareen Subhash;Chauhan, Vishal Rajendrabhai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.79-88
    • /
    • 2021
  • Purpose. To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion. Materials and methods. A 3-D finite element model of mandible with D2 bone with partially edentulism with unilateral distal extension was made. Two Ti alloy identical implants with 4.2 mm diameter and 10 mm length were placed in the mandibular second premolar and the mandibular second molar region and prosthesis was given with the mandibular first molar pontic. Vertical load of 100 N and and oblique load of 70 N was applied on occlusal surface of prosthesis. Group 1 was cuspally loaded occlusion with total 8 contact points and Group 2 was implant protected occlusion with 3 contact points. Results. In Group 1 for vertical load, maximum stress was generated over implant having 14.3552 Mpa. While for oblique load, overall stress generated was 28.0732 Mpa. In Group 2 for vertical load, maximum stress was generated over crown and overall stress was 16.7682 Mpa. But for oblique load, crown stress and overall stress was maximum 22.7561 Mpa. When Group 1 is compared to Group 2, harmful oblique load caused maximum overall stress 28.0732 Mpa in Group 1. Conclusion. In Group 1, vertical load generated high implant stress, and oblique load generated high overall stresses, cortical stresses and crown stresses compared to vertical load. In Group 2, oblique load generated more overall stresses, cortical stresses, and crown stresses compared to vertical load. Implant protected occlusion generated lesser harmful oblique implant, crown, bone and overall stresses compared to cuspally loaded occlusion.

A retrospective comparison of clinical outcomes of implant restorations for posterior edentulous area: 3-unit bridge supported by 2 implants vs 3 splinted implant-supported crowns

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.223-235
    • /
    • 2022
  • PURPOSE. To compare the clinical outcomes of two types of implant restoration for posterior edentulous area, 3-unit bridge supported by 2 implants and 3 implant-supported splinted crowns. MATERIALS AND METHODS. The data included 127 implant-supported fixed restorations in 85 patients: 37 restorations of 3-unit bridge supported by 2 implants (2-IB), 37 restorations of 3 implant-supported splinted crowns (3-IC), and 53 single restorations (S) as controls. Peri-implantitis and mechanical complications that occurred for 14 years were analyzed by multivariable Cox regression model. Kaplan-Meier curves and the multivariable Cox regression model were used to analyze the success and survival of implants. RESULTS. Peri-implantitis occurred in 28.4% of 2-IB group, 37.8% of 3-IC group, and 28.3% of S control group with no significant difference. According to the implant position, middle implants (P2) of the 3-IC group had the highest risk of peri-implantitis. The 3-IC group showed a lower mechanical complication rate (7.2%) than the 2-IB (16.2%) and S control group (20.8%). The cumulative success rate was 52.8% in S (control) group, 62.2% in 2-IB group, and 60.4% in 3-IC group. The cumulative survival rate was 98.1% in S (control) group, 98.6% in 2-IB group, and 95.5% in 3-IC group. There was no significant difference in the success and survival rate according to the restoration type. CONCLUSION. The restoration type was not associated with the success and survival of implants. The risk of mechanical complications was reduced in 3 implant-supported splinted crowns. However, the middle implants of the 3 implant-supported splinted crowns had a higher risk of peri-implantitis.

R.P.I.(ring pin implant)를 응용한 치아의 재식과 이식 (Transplantation and Replantation Using R.P.I.(ring pin implant))

  • 김재철
    • 대한심미치과학회지
    • /
    • 제8권1호
    • /
    • pp.36-44
    • /
    • 1999
  • No one really doubts that the hottest area of dentistry in 21st century would most likely be 'implant'. With the support of a vast amount of research, implant has been successfully and rapidly absorbed into the field of general dentistry including private practitioners. For teeth with hopeless(or refractory) periodontitis or periapical pathosis, with no hesitation most dentists would think extraction as the sole treatment option followed by prosthodontic replacement possibly including implant. Not many dentists would take Trasplantation/Replantation as another treatment option for a particular condition. Dentistry is often more focused on 'Restoration' than 'Preservation' of natural dentition. 'Biologic Implant' is obviously much closer to the concept of 'Preservation'. Many different types of biologic implant system have been introduced to clinical dentistry so far. Many of those have failed to earn reasonable acknowledgement despite of the clinical success they brought. For some reason biologic implant has rather been alienated for long time. RPI(Ring Pin Implant) is designed to improve the prognosis and success rate of transplanted/replanted teeth. RPI is a Ti-based custom made implant system. It is fabricated either by electric casting or milling process. The major feature RPI gas is the 'ring & hole' structure. The hole should be no less than 1mm diameter to allow bone bridge formation thru it. The ring structure and bone bridge formation creates anti-torque activity, which largely increases the 'initial stability' of the transplanted/replanted teeth. It is also reported that RPI is beneficial in the aspect of resisting root resorption following replantation/transplantation procedure.

  • PDF

Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

  • Yunus, Barunawaty
    • Imaging Science in Dentistry
    • /
    • 제41권2호
    • /
    • pp.59-62
    • /
    • 2011
  • Purpose : This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). Materials and Methods : This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. Results : The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. Conclusion : CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.