• Title/Summary/Keyword: IMPLANT

Search Result 6,029, Processing Time 0.031 seconds

Implant complications in bruxism patients

  • Song, Ji-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.2
    • /
    • pp.149-150
    • /
    • 2021
  • Bruxism is defined as a parafunctional activity during sleep or while awake that includes locking and grinding of teeth and clenching. It generates excessive occlusal force that may lead to implant failure. Therefore, diagnosis of bruxism and providing specific protocols such as occlusal splint and/or injection of botulinum toxin before implant installation are important to prevent increases the risk of implant failure in bruxism patients.

Open and Closed Mouth Impression Techniques for Mandibular Implant Overdenture: Two Cases Report

  • Ha-Jin, Yoon;Jung-Yoon, Bae
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.152-161
    • /
    • 2022
  • Mandibular implant overdenture is a good treatment option for complete edentulous patients with restoring removable prosthesis. Mandibular implant overdenture with two implants and locator attachments is widely used. It is tissue-supported overdenture that is made with the concept of conventional complete denture fabrication. There are two patients who provided impressions by open mouth technique and closed mouth technique in each case. In both cases, mandibular implant overdentures were restored with functionally and aesthetically satisfying results.

Three-Dimensional Finite Element Analysis for Comparison between Titanium Implant Abutment and Zirconia Implant Abutment (지르코니아 임플란트 지대주와 티타늄 임플란트 지대주의 삼차원적 유한요소응력분석)

  • Yun, Mi-Jung;Kim, Chang-Weop;Jeong, Chan-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.51-61
    • /
    • 2011
  • Recently, restoring implants in the esthetically demanding region, zirconia-based materials are widely used due to their superior mechanical properties, accuracies, and esthetics. The purpose of this study was to investigate the load transfer and mechanical stability of zirconia and titanium implant abutments by using the three-dimensional finite element analysis model. The internal conical joint type and external butt joint type implant system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. An load of 250N was applied vertically beside 3mm of implant axis. Stress distribution of zirconia and titanium implant abutment is similar. The maximum equivalent stress of titanium implant abutment is lower than zirconia implant abutment about 15%. Howevere considering a high mechanical strength that exceed those of titanium implant abutment, zirconia implant abutment had similar mechanical stability of titanium implant abutment clinically.

Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants (Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교)

  • Park, Hyo-Sang;Yen, Shue;Jeoung, Seong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.295-307
    • /
    • 2006
  • Objective: The purpose of this study was to compare the histological and biomechanical characteristics of self-tapping and self-drilling microscrew implants. Methods: 112 microscrew implants (56 self-drilling and 56 self-tapping) were placed into the tibia of 28 rabbits. The implants were loaded immediately with no force, light (100 gm), or heavy force (200 gm) with nickel-titanium coil springs. The animals were sacrificed at 3- and 5-weeks after placement and histologic and histomorphometric analysis were performed under a microscope. Results: All microscrew implants stayed firm throughout the experiment. There was no significant difference between self-drilling and self-tapping microscrew implants both in peak insertion and removal torques. Histologic examinations showed there were more defects in the self-tapping than the self-drilling microscrew implants, and newly formed immature bone was increased at the interface in the self-tapping 5-week group. There was proliferation of bone towards the outer surface of the implant and/or toward the marrow space in the self-drilling group. Histologically, self-drilling microscrew implants provided more bone contact initially but the two methods became similar at 5 weeks. Conclusion: These results indicate the two methods can be used for microscrew implant placement, but when using self-tapping microscrew implants, it seems better to use light force in the early stages.

A Retrospective study of the type of patients, the distribution of implant and the survival rate of $Xive^{(R)}$ implant (($Xive^{(R)}$)임플란트 식립시 환자 유형 및 식립부 분포와 생존율에 대한 후향적 연구)

  • Myung, Woo-Chun;Lee, Jung-Seok;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.523-534
    • /
    • 2007
  • This study is an analysis of types of patients and distribution of implant site and survival rate of $Xive^{(R)}$ implant. The following results on patient type, implant distribution and survival rate were compiled from 324 implant cases of 140 patients treated at the periodontal dept. of Yonsei University Hospital and G dental clinic between February 2003 and April 2006. 1. There are no dissimilarities between men and women, with patients in their 30, 40, 50s accounting for 80% of patients and accounted for 82% of implant treatments; the largest share of patients and implant treatments. 2. Mn, posterior area. accounted for 57% of implant treatments followed by Mx. posterior area(29%), Mx, anterior area(8%) and Mn, anterior area(6%). 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 96% and fully edentulous patient accounted for the remaining 4%. 4. The major cause of tooth loss is periodontal disease, followed by dental canes, trauma and congenital missing. 5, The distribution of bone quality for maxillae was 54,2% for type III, followed by 30.8% for type II, 15% for type IV and 0% for type I. As for mandible, the distribution was 63% for type II, followed by 34% for type III, 2,5% for type I and 0,5% for type IV. 6. The distribution of bone quantity for maxillae was 55% for type C, followed by 35% for type B, 8% for type D and 2% for type A. As for mandible, the distribution was 60% for type B, followed by 32% for type C, 7% for type A and 0% for type D. 7. The majority of implants were those of 9.5-13 mm in length(95%) and regular diameter in width(82%). 8. The total survival rate was 98%. The survival rate was 97% in the maxillae region and 99% in the mandible region. 9. The survival rate in type I was 83%, in type II was 99%, in type III was 97% and in type IV was 100%. As for the bone quantity, the survival rate in type A and D(100%) was most, followed by type B(99%) and type C(96%). The results showed that $Xive^{(R)}$ implant could be used satisfactorily compare for the other implant system. But we most to approach carefully in certain extreme condition especially with poor bone quality and quantity.

AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS (Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구)

  • Woo, Jin-Oh;Park, Bong-Wook;Byun, June-Ho;Kim, Seung-Eon;Kim, Gyoo-Cheon;Park, Bong-Soo;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.52-59
    • /
    • 2008
  • The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

Three-dimensional finite element analysis on stress distribution of the mandibular implant-supported cantilever prostheses depending on the designs (임플란트 지지 하악 캔틸레버 보철물의 디자인에 따른 저작압 분산에 관한 삼차원 유한요소 분석)

  • Ban, Jae-Hyurk;Shin, Sang-Wan;Kim, Sun-Jong;Lee, Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.70-81
    • /
    • 2009
  • Statement of problem: The position and length of cantilever influence on the stress distribution of implants, superstructure and bone. In edentulous mandible, implant-supported cantilever prostheses that based 4 or 6 implants between mental foramens has been attempted. Excessive bite force loaded at cantilever prosthesis causes bone resorption and breakage of superstructure prosthesis around posterior implants. To complement the cantilever length of conventional prosthesis, In 1992, (McCartney) introduced "cantilever-rest-implant" and Malo reported "All-on-Four" in 2003. Purpose: Analyze and compare the stress distribution of conventional cantilever prostheses with rest implant and All-on-$Four^{TM}$ implant prostheses. Material and method: The external loads(300 N vertically, 75 N horizontally) are applied to first molar area. The stress value, stress distribution and aspect of stress dispersion are analyzed by three-dimensional finite element analysis program, ANSYS ver. 10.0. Results: 1. The rest implant and "All-on-Four" implant system are superior to conventional cantilever prostheses to reduce stress on the bone and the superstructure around implants. 2. The rest implant was of the greatest advantage to stress distribution on bone, implant and superstructure. 3. With same number of implants, distally tilted implants are preferred to conventional cantilever prostheses for reducing the length of cantilever.

The Study of Implant Patient's Type and Implant Distribution (임플란트 환자의 유형 및 분포에 대한 연구)

  • Hong, Sung-Jae;Paik, Jeong-Won;Kim, Chang-Sung;Choi, Seong-Ho;Lee, Keun-Woo;Chai, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.539-554
    • /
    • 2002
  • It has been approximately 40 years since $Br{{\aa}}nemark$ first introduced osseo-integration for implants in the early 1960s. Unlike crown and bridge or denture treatment, implant treatment helps preserve existing bone and improve masticatory functions. Thus, the awareness of implant treatment has grown rapidly among dentists and patients alike in Korea, as it becomes a widely accepted treatment. The following results on patients type and implant distribution were compiled from 1814 implant cases of 640 patients treated at the periodontal dept. of Y University Hospital during 1992 to 2001. 1. There are no dissimilarities between men and women, with patients in their 40,50s accounting for 49% of patients and 56% of implant treatments; the largest share of patients and implant treatments. 2. Mn. posterior area accounted for 59% of implant treatments followed by Mx. posterior area(21%), Mx anterior area(l4%) and Mn anterior area 2%. 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 98% and fully edentulous patient accounted for the remaining 2% 4. The major cause of tooth loss is periodontal disease, followed by dental caries, trauma and congenital missing. Compared to women, men are more likely to suffer from tooth loss due to periodontal disease. Also, older people are more likely to suffer from tooth loss due to periodontal disease rather than dental caries. 5. The distribution of bone quality for maxillae was 52% for type III, followed by 23% for type II, 20% for type IV and 0% for type I. As for mandible, the distribution was 52% for type II, followed by 37% for type III, 7% for type IV and 4% for type I. 6. The distribution of bone quantity for maxillae was 49% for type C, followed by 34% for type B, 14% for type D, 3% for type A, and 0% for type E. As for mandible, the distribution was 52% for type B, followed by 35% for type C, 6% for type D, 3% for type A and 0% for type E. 7. The majority of implants were those of 10-14mm in length (80%) and regular diameter in width (79%). The results provided us with basic data on patient type, implant distribution, bone condition, etc. We wish that our results coupled with other research data helps assist in the further study for better implant success/survival rates, etc.