AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS

Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구

  • Woo, Jin-Oh (Dr. Woo's Dental Clinic) ;
  • Park, Bong-Wook (Department of Oral & Maxillofacial Surgery, School of Medicine and Institute of Health Science, Gyeongsang National University) ;
  • Byun, June-Ho (Department of Oral & Maxillofacial Surgery, School of Medicine and Institute of Health Science, Gyeongsang National University) ;
  • Kim, Seung-Eon (Department of Materials Processing, Korea Institute of Machinery & Materials) ;
  • Kim, Gyoo-Cheon (Department of Oral Anatomy, School of Dentistry, Pusan National University) ;
  • Park, Bong-Soo (Department of Oral Anatomy, School of Dentistry, Pusan National University) ;
  • Kim, Jong-Ryoul (Department of Oral & Maxillofacial Surgery, School of Dentistry, Pusan National University)
  • 우진오 (우진오치과의원) ;
  • 박봉욱 (경상대학교 의학전문대학원 치과학교실 구강악안면외과, 경상대학교 건강과학연구원) ;
  • 변준호 (경상대학교 의학전문대학원 치과학교실 구강악안면외과, 경상대학교 건강과학연구원) ;
  • 김승언 (한국기계연구원 공정연구부) ;
  • 김규천 (부산대학교 치의학전문대학원 구강해부학교실) ;
  • 박봉수 (부산대학교 치의학전문대학원 구강해부학교실) ;
  • 김종렬 (부산대학교 치의학전문대학원 구강악안면외과학교실)
  • Published : 2008.01.31

Abstract

The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

Keywords

References

  1. Lee SC, Song WS : Histomorphometric and removal torque values comparison of rough surface titanium implants. J Kor Maxillofac Plast Reconstr Surg 23 : 396, 2001
  2. Kwak JW, Kim TH, Park HJ et al : Effect of implant surface characteristics on osseointegration in the ilium of dogs. J Kor Maxillofac Plast Reconstr Surg 26 : 531, 2004
  3. Predecki P, Auslaender BA, Stephan JE et al : Attachment of bone to threaded implants by ingrowth and mechanical interlocking. J Biomed Mater Res 6 : 401, 1972 https://doi.org/10.1002/jbm.820060507
  4. Martinez H, Davarpanah M, Missika P et al : Optimal implant stabilization in low density bone. Clin Oral Implants Res 12 : 423, 2001 https://doi.org/10.1034/j.1600-0501.2001.120501.x
  5. Buser D, Schenk RK, Steinemann S et al : Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 25 : 889, 1991 https://doi.org/10.1002/jbm.820250708
  6. Hong WS, Kim TH, Ryu SH et al : Comparative study of osseointegration of 4 different surfaced implants in the tibia of dogs. J Kor Oral Maxillofac Surg 31 : 46, 2005
  7. Maniatouplous C, Pilliar R, Smith D : Threaded versus porous surface design for implant stabilization in bone endodontic implant model. J Biomed Mater Res 20 : 1309, 1986 https://doi.org/10.1002/jbm.820200907
  8. Qui J, Dominichi JT, Lifland MI : Composite titanium dental implant fabricated by electro-discharge compaction. Biomaterials 18 : 153, 1997 https://doi.org/10.1016/S0142-9612(96)00097-X
  9. Simmons CA, Valiquette N, Pilliar RM : Osseointegration of sintered porous-surfaced and plasma spray-coated implants : an animal model study of early postimplantation healing respose and mechanical stability. J Biomed Mater Res 47 : 127, 1999 https://doi.org/10.1002/(SICI)1097-4636(199911)47:2<127::AID-JBM3>3.0.CO;2-C
  10. Simmons CA, Meguid SA, Pilliar RM : Differences in osseointegration rate due to implant surface geometry can be explained by local tissue strains. J Orthoped Res 19 : 187, 2001 https://doi.org/10.1016/S0736-0266(00)90006-8
  11. Pilliar RM : Porous-surface metallic implants for orthopedic applications. J Biomed Mater Res 21 : 1, 1987 https://doi.org/10.1002/jbm.820210106
  12. Kariagienes M, Westerman R, Hamilton A : Investigation of long term performance of porous metal implants in nonhuman primates. J Oral Implant 10 : 189, 1982
  13. Deporter DA, Watson PA, Pilliar RM et al : A histological assessment of the initial healing response adjacent to porous-surfaced titanium alloy dental implants in dogs. J Dent Res 65 : 1064, 1986 https://doi.org/10.1177/00220345860650080501
  14. Tache A, Gan I, Deporter DA et al : Effect of surface chemistry on the rate of osseointegration of sintered porous-surfaced Ti-6Al-4V implants. Int J Oral Maxillofac Impl 19 : 19, 2004
  15. Rahmani M, Shimada E, Rokni S et al : Osteotome sinus elevation and simultaneous placement of porous-surfaced implants: a morphometric study in rabbits. Clin?Oral Impl Res 16 : 692, 2005 https://doi.org/10.1111/j.1600-0501.2005.01163.x
  16. Watzek G, Haas R : Internal augmentation of the alveolar crest with the sinus membrane for guided bone regeneration. Oral Maxillofac Surg Clin North Am 13 : 511, 2001
  17. Davies JE : Mechanism of endosseous integration. Int J Prosthodont 11 : 391, 1998
  18. Pauwels F : Biomechanics of the locomotor apparatus, Berlin, Springer-Verlag, 1980, p.518
  19. arter DR, Giori NJ : Effect of mechanical stress on tissue differentiation in the bony implant bed, Toronto, University of Toronto Press, 1991, p.367
  20. Thomson GJ, Puleo DA : Ti-6Al-4V ion solution inhibition of osteogenic cell phenotype as a function of differentiation time-course in vitro. Biomater 17 : 1949, 1996 https://doi.org/10.1016/0142-9612(96)00009-9
  21. Bobyn J, Pilliar R, Cameron H et al : The optimum pore size for the fixation of porous surface metal implants by the ingrowth of bone. Clin Orthop 176 : 52, 1980