• Title/Summary/Keyword: II-VI

Search Result 608, Processing Time 0.028 seconds

Correlation between Chest Radiographic Findings and Respiratory Indices in Neonates with Respiratory Distress Syndrome (신생아 호흡곤란 증후군에서 흉부방사선 소견과 Respiratory Index와의 관계)

  • Chung, Yong-Hwan;Park, Youn-Jin;Bae, Chong-Woo;Sung, Dong-Wook
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.7
    • /
    • pp.655-660
    • /
    • 2003
  • Purpose : The relationship between chest X-ray findings and respiratory indices, including the arterial-alveolar oxygen partial pressure ratio($a/APO_2$) and the ventilatory index(VI), indicators of the clinical respiratory status in neonates with respiratory distress syndrome(RDS), was examined in the present study. Methods : The records of 50 neonates, randomly chosen from 174 neonates treated with pulmonary surfactant(PS) in the Neonatal Intensive Care Unit of Kyunghee University Hospital from 1996 to 2000 were analyzed retrospectively. Chest radiographs taken at the time after birth were classified into four groups according to Bomsel's classification. The $a/APO_2$ and VI values were calculated and compared with the corresponding chest radiographs. Results : Among the 50 cases of RDS examined, three cases were classified into grade I(6%), eight cases into grade II(16%), 20 cases into grade III(40%), and 19 cases into grade IV(38%). The mean $a/APO_2$ of the cases classified into grades I or II was 0.32 and the mean $a/APO_2$ of those classified into grades III and IV was 0.18 and 0.09, respectively. The mean VI was 0.049 for the cases classified into grades I or II and 0.076 and 0.161 for those classified into grades III and IV, respectively. Conclusion : The severity of RDS according to chest X-ray findings correlate to the values of respiratory indices, $a/APO_2$ and VI.

Adsorption of U(VI), Fe(II), Sm(III) Ions on OenNen-Styrene DVB Synthetic Resin (OenNen-Styrene DVB 합성수지에 의한 U(VI), Fe(II), Sm(III) 이온들의 흡착)

  • Lee, Chi-Young;Kim, Joon-Tae
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.77-87
    • /
    • 2007
  • The ion exchange resins have been synthesized from chlormethyl styrene - 1,4 - divinylbenzene(DVB) with 1%, 3%, and 5%-crosslinking and macro cyclic ligand of OenNen-$H_4$ by copolymerization method and the adsorption characteristics of uranium(VI), iron(II) and samarium(III) metallic ions have been investigated in various experimental conditions. The synthesis of these resins was confirmed by content of chlorine, element analysis, and IR-spectrum. The effects of pH, time, dielectric constant of solvent and crosslink on adsorption of metallic ions were investigated. The uranium ion was showed fast adsorption on the resins above pH 3. The optimum equilibrium time for adsorption of metallic ions was about two hours. The adsorption selectivity determined in ethanol was in increasing order uranium ${UO_2}^{2+}>Fe^{2+}>Sm^{3+}$ ion. The adsorption was in order of 1%, 3%, and 5% crosslink resin and adsorption of resin decreased in proportion to order of dielectric constant of solvent.

The study of characteristics of II-VI group chemical semiconductor by the kVp variation to development X-ray dosimeter (X-ray dosimeter 개발을 위한 II-VI 족 화합물 반도체의 kVp 변화에 따른 특성 연구)

  • Eun, C.K.;Cho, S.Y.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.23-26
    • /
    • 1997
  • In exposuring x-rays, we can adjust three variables of kVp, mA and sec. The kVp is one of main factors affecting x-ray quality -peneterability. And miliampere-seconds is directly proportional to x-ray quantity. In this paper, we detected voltage variation of CdS, II-VI group semiconductor compounds, by kVp as the fundamental experiments of designing x-ray dosimeter. We exposured x-ray on the material from 40 to 100 kVp by increasing 2kVp using Shimadazu TH-500-125 Radio-Tex cx-s x-ray machine. We fixed miliampere -seconds to 100mA and 0.2 sec. After acquiring the raw data, we plotted the graph of kVp and voltage variation and figured slope value of 0.093 by regression. The standard deviation of voltage to kVp was 0.22. For the future study, the mAs variation study will be needed to investigate the connections between kVp and mAs in order to design x-ray dosimeter.

  • PDF

Adsorption Characteristic of U(VI), Cu(II), Dy(III) Ions Utilizing Nitrogen-Donator Synthetic Resin (질소-주게 합성수지를 이용한 U(VI), Cu(II), Dy(III) 이온들의 흡착특성)

  • Rho, Gi-Hwan;Kim, Joon-Tae;Kim, Hee-Joung
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.3 s.61
    • /
    • pp.52-60
    • /
    • 2006
  • The ion exchange resins have been synthesized from chlormethyl styrene-1,4-divinylbenzene(DVB) with 1%, 2%, and 20%-crosslinking and macrocyclic ligand of cryptand 21 by copolymerization method and the adsorption characteristics of uranium(VI), copper(II) and dysprosium(III) metallic ions have been investigated in various experimental conditions. The synthesis of these resins was confirmed by content of chlorine, element analysis, and IR-spectrum. The effects of pH, equilibrium time, dielectric constant of solvent and crosslink on adsorption of metallic ions were investigated. The metal ion was showed fast adsorption on the resins above pH 3. The optimum equilibrium time for adsorption of metallic ions was about two hours. The adsorption selectivity determined in ethanol was in increasing order uranium$(UO^{2+}_2)\;>\;copper(Cu^{2+})\;>\;dysprosium(Dy^{3+})$ ion. The adsorption was in order of 1%, 2%, and 20% crosslink resin and adsorption of resin decreased in proportion to order of dielectric constant of solvents.

The Preferred Orientation of CdSe and CdS Thin Films on the AlOx and SiO2 Templates (AlOx와 SiO2 형판위 CdSe와 CdS 박막의 우선방위(Preferred Orientation) 특성)

  • Lee, Young-Gun;Chang, Ki-Seog
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.502-506
    • /
    • 2012
  • In order to find the structural characteristics of the thin films of group II-VI semiconductor compounds compared with those of powder materials, films were made of 4 powders of ZnS, CdS, CdSe, and CdTe(Aldrich), each with 99.99 % purity. For the ZnS/CdS multi-layers, the ZnS layer was coated over the CdS layer on an $AlO_x$ membrane, which served as a protective layer within a vacuum at the average speed of 1 ${\AA}$/sec. After studying the structures of the group II-VI semiconductor thin films by using X-ray spectroscopy, we found that the ZnS, ZnS/CdS, CdS, and CdSe films were hexagonal and exhibited some degree of preferred orientation. Also, the particles of the thin films of II-VI semiconductor compounds proved to be more homogeneous in size compared to those of the powder materials. These results were further verified through scanning electron microscopy(SEM), EDX analysis, and powder and thin film X-ray diffraction.

A Comparison between Bacterial Cr(VI) Resistance and Cr(VI) Reduction among Environmental Isolates (미생물의 크롬내성과 크롬환원의 상호 비교)

  • 오영숙;최성찬
    • Korean Journal of Microbiology
    • /
    • v.33 no.2
    • /
    • pp.125-130
    • /
    • 1997
  • Microbial reduction of hexava1ent(VI) to trivalent(lII) chromium is regarded as one of the mechanisms that confers resistance to bacteria. In order to verify this hypothesis, we compared Cr(VI) resistance with Cr(VI) reduction among 20 phenotypically distinct environmental isolates from Cr-contaminated and uncontaminated soils. With glucose as an electron donor, Cr(VI) reduction by washed cell suspensions ranged from 0.014 to 0.305 mM Cr(VI) reduced $h^1$. Cr(VI) resistance of the isolates were measured by growth inhibitions on a liquid medium containing 2 mM Cr(VI) based on their decrease of $A_{630}1$ as compared to the controls without Cr(VI). The isolates had a broad range of resistance from no inhibition to 93.4% inhibition of their growth. Upon correlation analysis, there was no significant relationship between those two phenomena. At a population level, a comparison of % resistant viable counts among the Cr-contaminated and uncontaminated soils showed 19.1 % and 0.4% of their total viable counts, respectively. The difference of % resistance between two site,. strongly suggested that the Cr(VI) present in the soils influences natural selection for resistant phenotypes. However, it is unlikely that the Cr(VI) resistance is dependent solely on the reduction as judged by the correlation analysis.

  • PDF

Analysis of Heavy Metal Toxic Ions by Adsorption onto Amino-functionalized Ordered Mesoporous Silica

  • Showkat, Ali Md;Zhang, Yu-Ping;Kim, Min-Seok;Gopalan, Anantha Iyengar;Reddy, Kakarla Raghava;Lee, Kwang-Pill
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.11
    • /
    • pp.1985-1992
    • /
    • 2007
  • Ordered mesoporous silica (MCM-41) materials with different textural properties were prepared using alkyl (dodecyl, cetyl, eicosane) trimethyl ammonium bromide (DTAB, CTAB, ETAB, respectively) as structure directing surfactants, functionalized with amine groups and used as adsorbent for the toxic metal ions, Cr (VI), As (V), Pb (II) and Hg (II). Amino functionalization of mesoporous MCM-41 was achieved by cocondensation of N-[3-(trimethoxysilyl)-propyl] aniline with tetraethyl orthosilicate. Adsorption isotherm and adsorption capacity of the amine functionalized materials for Cr (VI), As (V), Pb (II) and Hg (II) ions were followed by inductively coupled plasma mass spectrometry (ICP-MS). Results demonstrate that amine functionalized MCM-41 prepared with ETAB showed higher adsorption capacity for Cr (VI), As (V), Pb (II) and Hg (II) ions in comparison to MCM-41 prepared with CTAB and DTAB. The higher adsorption capacity for MCM-41(ETAB) was correlated with amine content in the material (determined by CHN analysis) and relative decrease in pore volume and pore diameter. X-ray diffraction (XRD) analysis, nitrogen adsorptiondesorption measurements and Fourier Transform infrared spectrometry (FTIR) were used to follow the changes in the textural parameters and surface properties of the mesoporous materials as a result of amine functionalization to correlate with the adsorption characteristics. The adsorption process was found to depend on the pH of the medium.

Electronic Structure of Iron and Molybdenum in $Li_2FeMoO_4Cl$ and Its Crystal Symmetry ($Li_2FeMoO_4Cl$의 결정구조와 Fe 및 Mo의 전자구조 연구)

  • Choy, Jin-Ho;Park, Nam-Gyu;Chang, Soon-Ho;Park, Hyung-Ho
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.6
    • /
    • pp.446-452
    • /
    • 1995
  • Lithium intercalates, $Li_xFeMoO_4Cl$ ($1{\leq}X{\leq}2$) prepared by electrochemical lithiation of $FeMoO_4Cl$ crystallizes in monoclinic structure for all x values as revealed by x-ray diffraction and galvanostatic discharge experiments. According to the x-ray photoelectron spectroscopic study, Fe(III) is at first reduced to Fe(II) upon lithium intercalation with the x domain of $0{\leq}X{\leq}1$, where the crystal symmetry is changed from tetragonal to monoclinic. On the other hand, Mo(VI) is reduced to lower valent state upon further lithium intercalation ($1{\leq}X{\leq}2$), where no crystal symmetry transformation and reduction of Fe(II) to lower valent state are observed. The Mo 3d spectrum for $Li_2FeMoO_4Cl$ appears as a complex shape, but can be deconvoluted into the three sets of the doublet on the basis of Gaussian function, those which correspond to Mo(VI), Mo(V) and Mo(IV) states, respectively. The mixed valent states of molybdenum after further lithiation may be due to a competitive reaction between the formation of Mo(V) and its disproportionation to Mo(IV) and Mo(VI).

  • PDF