• Title/Summary/Keyword: Hydrometer method

Search Result 23, Processing Time 0.028 seconds

Comparison of Micro-Pipette Method and Hydrometer Method in Soil Particle Size Analysis (Micro-Pipette법과 Hydrometer법에 의한 토양 입경 분석의 비교)

  • Chung, Jong-Bae;Kim, Min-Kyeong;Kim, Bok-Jin;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.3
    • /
    • pp.274-278
    • /
    • 1999
  • Determination of soil texture, particularly the clay fraction, is an important measurement in most researches related with soil. In this study micro-pipette method For soil particle size analysis was compared with the standard hydrometer method. Micro-pipette method can eliminate the need for bulky laboratory equipment and long settling times associated with the standard hydrometer or pipette method. In the results of this investigation, the particle size data obtained with micro-pipette method were in good agreement with those found using standard hydrometer method. And with this method one person could run analysis much larger numbers of soil sample per day than with hydrometer method in relatively small laboratory space.

  • PDF

Rapid Evaluation Method for Blast Furnace Slag Fineness and Influence of Fineness on Properties of Cement Mortar (고로슬래그의 분말도 신속평가 및 분말도가 시멘트 모르타르의 특성에 미치는 영향)

  • Han, Cheon-Goo;Joo, Eun-Hee
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.5
    • /
    • pp.13-18
    • /
    • 2018
  • In this research, regarding the type three blast furnace slag (BS) regulated by KS F 2563 and supplied to actual ready mixed concrete plant, the fineness on specification and actually measured fineness by Blain test were compared, and by applying the hydrometer method used for early prediction of concrete strength, the feasibility of the hydrometer method for acquisition inspection of BS was analyzed. Additionally, the influence of various fineness of BS on properties of cement mortar was also assessed. According to the experimental results of this research, correlation of fineness values between specification and actually measured data were not matched. In the case of the rapid evaluation method using hydrometer, a good relation was shown between the fineness data obtained from hydrometer and Blain test. furthermore, from the cement mortar properties test, there was a good relation was obtained between fineness data from rapid evaluation method by hydrometer and cement mortar properties, while there was no clear relation between fineness data from specification and cement mortar properties. Hence, as a qulity controlling method of BS fineness, a rapid evaluation method using hydrometer is suggested as a new method.

Feasibility Analysis of Rapid Quality Evaluation Method for Blast Furnace Slag Using Hydrometer (Hydrometer를 이용한 고로슬래그 미분말의 분말도 품질 신속평가 가능성 분석)

  • Han, Cheon-Goo;Joo, Eun-Hui
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.43-49
    • /
    • 2018
  • The aim of the research is to analyze the feasibility of rapid quality evaluation method for blast furnace slag using hydrometer based on the former research of the prediction method for concrete compressive strength using hydrometer. Using this method, it is expected to provide a new application for blast furnace slag quality evaluation easily and rapidly during the receiving inspection. According to the experimental results, the settling time period of hydrometer was delayed with increased fineness of blast furnace slag. By using the regression equation of y = 198 120 x - 193 936(R=0.9398) obtained from the correlation between density of suspension at three minutes and fineness, it was possible to evaluate the quality of blast furnace slag fineness rapidly. Therefore, for ready-mixed concrete receiving inspection, the suggested method can be used as a cheap, a simple, and a rapid inspection method.

Analysis of the Correlation Between the Density of the Hydrometer Method and Fly Ash Fineness in Acceptance Inspection (인수검사시 Hydrometer법의 밀도 값과 플라이애시의 분말도간 상관관계 분석)

  • Moon, Byeong-Yong;Hyun, Seong-Yong;Lee, Jae-Jin;Song, Heung-Ho;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.20-21
    • /
    • 2017
  • There have been reports in the media about some refineries that omit the refining process and deliver raw material for reasons of cost reduction, shortening of production time, etc. Also, in most RMC factories acceptance inspection is not conducted on account of issues with the proficiency of the equipment and cost issues; instead only scores are relied upon. Therefore this study sought to analyze the relation between the value of the density of FA actually delivered to RMC companies, attained with the Hydrometer method, and its fineness, to see whether the quality of FA can be evaluated statistically. Results led to the conclusion that there is a problem in terms of credibility in the fineness of FA shown on the test report. Upon analyzing the difference between the fineness of FA as measured using Blaine's air permeability method and its density of the Hydrometer method, the correlation was found to be satisfactory; therefore the possibility of a FA fineness quality evaluation could be proved as well.

  • PDF

A Feasibility Analysis of Rapid Acquisition Test for Cement Fineness using Hydrometer (시멘트 인수검사 시 액체밀도계법에 의한 분말도 품질 신속평가 가능성 분석)

  • Han, Cheon-Goo;Kim, Young-Tae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.29-34
    • /
    • 2018
  • In this research, regarding the cement supplied to ready mixed concrete plant, the feasibility of rapid acquisition test for cement fineness using hydrometer which used for early strength evaluation of concrete was analyzed. Additionally, regarding the rapid test with hydrometer control factors were provided. As a result of analysis, quality control using hydrometer was possible with the regressive equation obtained in five minute between density of suspension and fineness of cement powder. As the control factors, dispersing admixture, replacing kerosene as a medium, and temperature of cement and water were evaluated. According to the control factor evaluation, the tap water was optimum as a medium and calibration of keeping the temperature of water to $20^{\circ}C$ or correction factor was needed for density results. Finally, it is considered that the suggested rapid quality evaluation method using hydrometer is cheaper and easier method than currently used Blaine test.

Type of Solution and the Effects of Temperature Change in a Rapid Appraisal of Cement Fineness with a Liquid Densimeter (액체밀도계에 의한 시멘트의 분말도 신속평가에서 용액 종류 및 온도변화의 영향)

  • Lee, Jae-Jin;Kim, Min-Sang;Moon, Byeong-Yong;Kim, Yeong-Tae;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.167-168
    • /
    • 2017
  • With the recent increase in demand for construction there has been an increase in the use of the raw material cement when mixing concrete; managing quality of cement powder, therefore, is most important. Therefore this study sought at first to develop a rapid appraisal using the Hydrometer method researched previously, for it was thought that when suspending cement in a solution and applying the Hydrometer method to it the temperature changes in the solution would have a great effect on the density value of the Hydrometer method; yet there has been no report of such influence factors. Therefore after analyzing the influence factors that the type of suspending solution and changes in temperature could have on rapid appraisal of fineness, using the Hydrometer method, this study was able to determine that using water at 20℃ was the most appropriate, and with every temperature increase of 10℃ the value of fineness should also be increased above or below 7% as well.

  • PDF

Implementation on the Portable Blood Gas Analyzer and Performance Estimation/A Study on the Hydrometer Calibration System using Image Processing (영상처리 기법을 이용한 부액계 자동 교정 시스템 구현)

  • Lee, Yong-Jae;Chang, Kyung-Ho;Oh, Chae-Youn;Jung, Sang-Duk
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.258-264
    • /
    • 2003
  • The present paper studies how to calibrate hydrometer using image process. The method aligns particular scales of hydrometer selected for calibrating the hydrometer with the horizontal plane of the reference liquid automatically without man's operation. Major parts composing the system are CCD camera, frame grabber, stepping motor and image process program. The image process program is composed of a part that locates the meniscus and aligns it with a scale and a part that controls the step motor. To verify the performance of the developed method, this study compares the meniscus and scale observed directly with the naked eye with the result of calibration by the manual calibration method. The differences between the corrections were less than $0.004\;kg/m^3$ with uncertainty of $0.06\;kg/m^3$. These showed that the calibration results of the developed hydrometer calibration using image process nearly equal to manual method.

Quick evaluation for cement powder of synthesize with the hydrometer density value and change temperature (Hydrometer의 밀도 값과 혼탁액 온도를 복합한 포틀랜드 시멘트의 분말도 신속 평가)

  • Lee, Jae-Jin;Han, Jun-Hui;Hyun, Seong-Yong;Kim, Yeong-Tae;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.87-88
    • /
    • 2018
  • The change in the degree of powder in cement is very important because it plays a major role in the reaction in the concrete. In this study, we intend to apply the principle of early estimation of concrete strength using the non-middling method previously conducted to the quality evaluation of cement powder. In other words, it is proposed to analyze the potential of Hydrometer density values and the data of temperature variation in the trust solution to propose a method of acceptance inspection. According to the experimental results, the quick evaluation of the cement distributorship will be possible if the resulting regression results are used : y = 161867.4 x1 + 117.953 x2 - 165437 (R = 0.9158).

  • PDF

A Precision Test of Hydrometer Method for Determining Soil Texture (비중계법에 의한 토성분석시 정도 실험)

  • Kim, Lee-Yul;Han, Kyung-Hwa;Cho, Hyun-Jun;Oh, Dong-Shig
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.5
    • /
    • pp.315-320
    • /
    • 2006
  • A precision test of hydrometer method, used to determine soil texture, was conducted on selected 10 soil samples, compared to pipette method. Soil texture measurements with hydrometer method were performed with monitoring the temperature of soil suspension in settling cylinder. The temperature and its fluctuation during settling time had a range of $13^{\circ}C-28^{\circ}C$ and $0.2^{\circ}C-4.4^{\circ}C$, respectively. The difference of clay content between hydrometer and pipette method were distributed from -6.4% to 4.0%. Positive end of difference in clay content was observed at soil having very low clay content, whereas negative end at soil having high organic matter content and exchangeable cations. Except both ends, difference in clay content of soils was less than 3%, and expecially closed to 0% in soils having clay content more than 25%. The difference of sand content were distributed from -1.5% to 4.2%. Similar to clay content, positive end soil was soil sample having lowest sand content.

Analysis of FA Quality through Correlation Analysis between Density Measured with the Hydrometer Method and the Test Report (Hydrometer법에 의한 밀도 값과 시험 성적서간 상관분석을 통한 플라이애시의 품질분석)

  • Moon, Byeong-Yong;Kim, Tae-Woo;Lee, Jae-Jin;Song, Heung-Ho;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.226-227
    • /
    • 2017
  • Basic lot tests via textile and visual examinations are conducted on FA carried into in-service RMCs. The system of evaluating quality by taking samples from each lot and examining them, or evaluating quality based on the score reports submitted by the deliverer during in-service training have on some instances been called into doubt as to their reliability in evaluating the quality of FA. Therefore this study sought to measure the density value of FA that is actually delivered to RMC companies according to the Hydrometer method and analyze its correlation to its test scores, to in turn analyze the reliability of the test reports and the characteristics of the quality of FA. The results led to the conclusion that the fineness and density marked on the score reports were problematic, and therefore accurate experiments and adjustment of significant digits on the test report are necessary.

  • PDF