• Title/Summary/Keyword: Hydrogen refueling stations

Search Result 50, Processing Time 0.018 seconds

A Study on Safety Improvement for Mobile Hydrogen Refueling Station by HAZOP Analysis (위험과 운전 분석을 통한 이동식 수소충전소 안전성 향상에 관한 연구)

  • BYUN, YOON-SUP
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.299-307
    • /
    • 2021
  • In order to expand the supply of hydrogen vehicles, the first thing to be done is to build an infrastructure to supply hydrogen. There are fixed and mobile types of hydrogen refueling stations that can supply hydrogen. Mobile hydrogen refueling stations have the advantage of supplying hydrogen to two or three areas, so the introduction of mobile hydrogen refueling stations is considered at the initial stage of hydrogen vehicle dissemination. However, mobile hydrogen refueling stations have greater risks than fixed hydrogen refueling stations due to the hazard associated with movement and intensive installation of facilities in vehicle, so stricter design standards to lower the risk must be applied. Therefore, in this study, basic data for establishing safety standards for mobile hydrogen refueling stations were proposed by suggesting improvements such as the location of emergency shutoff valves, the number of gas detectors etc., using HAZOP analysis.

Analysis of Costs for a Hydrogen Refueling Station in Korea (한국 수소 충전소 건설의 경제성 분석)

  • KANG, BYOUNGWOO;KIM, TAEHYUN;LEE, TAECKHONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.3
    • /
    • pp.256-263
    • /
    • 2016
  • As the hydrogen era comes near future, hydrogen fuel cell vehicles are core of hydrogen economy. Until now, Korea has 17 hydrogen refueling stations but 9 hydrogen refueling stations have been retired already and 8 hydrogen refueling stations are still running. With a limited number of hydrogen refueling stations, it is very difficult to get scientific data for the economy of hydrogen refueling stations in Korea. Thus, based on NREL(National Renewable Energy Laboratory) study, we analyzed most recent data for the construction of hydrogen refueling stations in one specific site in Korea. The cost comparison data between Korea and USA shows 14% difference, saying higher costs of Korea. Korea looks 5 years delay compared to USA. This data will be an important tool for the investment from every industrial parties.

Hydrogen Refueling Stations Improving Safety and Economic Feasibility (안전성과 경제성이 개선된 수소충전소)

  • YunSil Huh;DongHoon Lee;Yongjin Chung;Yongchai Kwon
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.611-618
    • /
    • 2023
  • The purpose of the refueling protocol and the contents of SAE J2601, which is used as the basis for hydrogen vehicles refueling around the world, were investigated, and research contents related to domestic protocols were also investigated. In addition, the components of the hydrogen refueling performance evaluation device developed in Korea and the method for evaluating the performance and safety of hydrogen refueling stations were reviewed. And, the result were analyzed by applying it to the hydrogen refueling stations currently operating in Korea. In addition, an economic feasibility analysis was conducted using data collected from domestic hydrogen refueling stations. In order to secure the safety and economy of a hydrogen refueling station, the protocol must be satisfied, and in order to satisfy the protocol, it is necessary to evaluate whether the refueling temperature, refueling pressure, and refueling flow are controlled within a safe range.

Analysis of the Economy of Scale for Domestic Steam Methane Reforming Hydrogen Refueling Stations Utilizing the Scale Factor (Scale Factor를 이용한 국내 천연가스 개질식 수소충전소의 규모의 경제 분석)

  • GIM, BONGJIN;YOON, WANG LAI;SEO, DONG JOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.251-259
    • /
    • 2019
  • The aim of this study is to evaluate the economic feasibility of domestic on-site steam methane reforming (SMR) hydrogen refueling stations. We evaluated the levelized cost of hydrogen (LCOH) for the SMR hydrogen refueling stations, which have production capacities of 100 kg/day (SMR 100), 200 kg/day (SMR 200), and 500 kg/day (SMR 500) utilizing the scale factor. The main results indicated that the LCOH of SMR 100, SMR 200, and SMR 500 were 14,367 won/kg, 11,122 won/kg, and 8,157 won/kg, if the utilizations of hydrogen stations were 70%. These results imply that the production capacity of the domestic SMR hydrogen station should be greater than 500 kg/day to compete with other hydrogen stations when we consider the current sale price of hydrogen at the hydrogen stations.

A Study on Safety Guidelines for Hydrogen Refueling Stations at Expressway Service Area using Quantitative Risk Assessment (정량적 위험성 평가를 통한 고속도로 휴게소 수소 충전소 안전 가이드라인 연구)

  • KIM, HEE JIN;JANG, KYEONG MIN;KIM, SOO HYEON;KIM, GI BEOM;JUNG, EUN SANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.551-564
    • /
    • 2021
  • The use of clean energy based on the hydrogen economy is increasing rapidly due to the greenhouse gas reduction policies and the increase in the need for hydrogen. Currently, South Korea government have been considering a plan to construct hydrogen refueling stations at expressway service area for the purpose of supplying hydrogen vehicles. In the case of a hydrogen refueling stations, a quantitative risk assessment (QRA) must be performed because it includs and uses a high pressurized hydrogen storage tank. In this study, QRA was conducted using societal risk and F-N curve by the consequence assessment (CA) of jet fire and explosion according to the population density, capacity of the high pressurized hydrogen storage tank and frequency assessment (FA) data to the general hydrogen refueling stations systems in expressway service area. In the cases of jet with a leak diameter of 7.16 mm, regardless of expressway service area location, the societal risk was over 1E-04 that was acceptable for as Low As reasonably practicable (ALARP) region (workforce), but unacceptable for ALARP region (public). In the cases of gas explosion, all expressway service area satisfy ALARP region. In the case of the population density is over 0.0727, QRA for constructing the hydrogen refueling stations, must be conducted.

Analysis of Back-to-back Refueling for Heavy Duty Hydrogen Fuel Cell Vehicles Using Hydrogen Refueling Stations Based on Cascade System (캐스케이드 시스템 기반 수소 충전소를 이용한 대형 수소 연료 전지 차량 연속 충전 분석)

  • GYU SEOK SHIM;BYUNG HEUNG PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.3
    • /
    • pp.300-309
    • /
    • 2024
  • Hydrogen utilization in the transportation sector, which relies on fossil fuels, can significantly reduce greenhouse gas by using to hydrogen fuel cell vehicles, and its adoption depends performance of hydrogen refueling station. The present study developed a model to simulate the back-to-back filling process of heavy duty hydrogen fuel cell vehicles at hydrogen refueling stations using a cascade method. And its quantitatively evaluated hydrogen refueling station performance by simulating various mass flow rates and storage tank capacity combinations, analyzing vehicle state of charge (SOC) of vehicles. In the cascade refueling system, the capacity of the high-pressure storage tank was found to have the greatest impact on the reduction of filling time and improvement of efficiency.

Safety Analysis of Potential Hazards at Hydrogen Refueling Station (수소충전소 잠재적 위험에 대한 안전성해석)

  • Park, Woo-Il;Kim, Dong-Hwan;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.43-48
    • /
    • 2021
  • This study was conducted using FLACS, a specialized gas accident analysis program. Hydrogen refueling stations subject of safety analysis, consist of compression facilities, storage tanks, and hydrogen piping. The safety analysis of potential risk factors was conducted after reflecting the design specifications of major facilities and components, environmental conditions around hydrogen refueling stations, etc. As of 2021, about 70 refueling stations in Korea are available, and 1,200 are scheduled to be introduced in the next 2040. To prepare for possible accidents caused by potential hazards for the safe distribution of hydrogen refueling stations, we intend to derive hydrogen leakage diffusion scenarios and review their safety.

Development of Hydrogen Flow Field Standard in Hydrogen Refueling Station (수소충전유량 현장교정시스템의 개발 )

  • WOONG KANG;JINWOO SHIN;SAENG-HEE LEE;BYUNG-RO YOON;UNBONG BAEK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.684-691
    • /
    • 2022
  • Hydrogen fuel cell electric vehicles are typically refueled at a wide range of temperatures (-40℃ to 85℃) in the hydrogen refueling station in accordance with the worldwide accepted standard. Currently, there is no traceable method by which to verify and calibrate the hydrogen flowmeters to be used at hydrogen refueling stations except for a water calibration process as a conventional method. KRISS hydrogen field test standard based on the gravimetric principle was developed to verify the measurement accuracy of the mass flowmeter to be used at hydrogen refueling stations for the first time in Korea.

The Factor Analysis for Acceptance on Hydrogen Refueling Station Using Structure Equation Model (구조방정식 모델을 이용한 수소충전소 수용에 미치는 요인분석)

  • Lee, Mi Jeong;Baek, Jong-Bae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.356-362
    • /
    • 2022
  • Research related to hydrogen technology is being actively conducted around the world. Korea is also making great efforts to develop technology to leap forward as a hydrogen economy powerhouse. In particular, the world's No. 1 hydrogen vehicle penetration rate is proof of this. However, the construction of hydrogen refueling stations is being delayed. The biggest delay factor is the public opposition. As such, policies without public support cannot be successfully implemented and are not sustainable. Therefore, this study intends to analyze the factors affecting the acceptability of hydrogen refueling stations in favor of and against them. As a research method, the basic factors affecting acceptability were identified by reviewing previous studies, and a questionnaire was designed and investigated based on the established factors. The validity and reliability of the questionnaire were verified, and the hypothesis was verified through correlation analysis. And, using structural equation modeling, a factor model was developed on the acceptability of hydrogen refueling stations. As a result of the study, acceptability defined private acceptability and public acceptability. In the case of private acceptability, it was confirmed that the higher the attitude toward the environment, the higher the level of knowledge about the hydrogen charging station, and the lower the degree of feeling the risk of the hydrogen charging station, the higher the acceptability. In the case of public acceptability, it was confirmed that the higher the benefit, the better the attitude toward the environment, and the lower the risk-taking characteristics of the individual, the higher the acceptability. Therefore, in this study, based on the potential factors verified in previous studies, the main factors affecting the acceptance on hydrogen refueling stations were identified. And the acceptance model was developed using structural equation modeling. This study is expected to provide basic data to seek ways to improve the acceptance of public when implementing national policies such as hydrogen refueling stations, and to be used analysis data for scientific communication.

A Study on the Achievement of Required Safety Integrity Level to Reduce Risk for SMR On-Site Hydrogen Refueling Stations (개질형 On-Site 수소충전소의 리스크 감소를 위해 요구되는 SIL 등급 달성 방안에 관한 연구)

  • Lee, Jin Ho;Lim, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.1-8
    • /
    • 2020
  • In recent years, hydrogen has received much attention as an alternative energy source to fossil fuels. In order to ensure safety from the increasing number of hydrogen refueling stations, prevention methods have been required. In this regard, this study suggested an approach to reduce the risk of hydrogen refueling station by increasing Safety Integrity Level (SIL) for a Steam Methane Reformer (SMR) in On-Site Hydrogen Refueling Station. The worst scenario in the SMR was selected by HAZOP and the required SIL for the worst scenario was identified by LOPA. To verify the required SIL, the PFDavg.(1/RRF) of Safety Instrumented System (SIS) in SMR was calculated by using realistic failure rate data of SIS. Next, several conditions were tested by varying the sensor redundancy and proof test interval reduction and their effects on risk reduction factor were investigated. Consequently, an improved condition, which were the redundancy of two-out-of-three and the proof test interval of twelve months, achieved the tolerable risk resulting in the magnitude of risk reduction factor ten times greater than that of the baseline condition.