Efficient use of ferrate(VI) in the oxidative removal of potassium hydrogen phthalate from aqueous solutions

  • Tiwari, Diwakar;Sailo, Lalsaimawia;Yoon, Yi-Yong;Lee, Seung-Mok
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.129-135
    • /
    • 2018
  • The aim of this study is to assess the applicability of ferrate(VI) in the efficient treatment of aqueous waste contaminated with potassium hydrogen phthalate (KHP) which is known to be a potent endocrine disrupting chemicals. Simulated batch reactor operations were conducted at a wide range of pH (7.0 to 12.0) and molar ratios of KHP to ferrate(VI). Kinetic studies were performed in the degradation process and overall rate constant was found to be 83.40 L/mol/min at pH 8.0. The stoichiometry of ferrate(VI) and KHP was found to be 1:1. Further, lower pH values and higher KHP concentrations were favoured greatly the degradation of KHP by ferrate(VI). Total organic carbon analysis showed that partial mineralization of KHP was achieved. The presence of several background electrolytes were studied in the degradation of KHP by ferrate(VI).

Degradation of Ultra-thin SiO2 film Incorporated with Hydrogen or Deuterium Bonds during Electrical Stress (수소 및 중수소가 포함된 실리콘 산화막의 전기적 스트레스에 의한 열화특성)

  • Lee, Jae-sung;Back, Jong-mu;Jung, Young-chul;Do, Seung-woo;Lee, Yong-hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.11
    • /
    • pp.996-1000
    • /
    • 2005
  • Experimental results are presented for the degradation of 3 nm-thick gate oxide $(SiO_2)$ under both Negative-bias Temperature Instability (NBTI) and Hot-carrier-induced (HCI) stresses using P and NMOSFETS, The devices are annealed with hydrogen or deuterium gas at high-pressure $(1\~5\;atm.)$ to introduce higher concentration in the gate oxide. Both interface trap and oxide bulk trap are found to dominate the reliability of gate oxide during electrical stress. The degradation mechanism depends on the condition of electrical stress that could change the location of damage area in the gate oxide. It was found the trap generation in the gate oxide film is mainly related to the breakage of Si-H bonds in the interface or the bulk area. We suggest that deuterium bonds in $SiO_2$ film are effective in suppressing the generation of traps related to the energetic hot carriers.

The Effect of Methane in Hydrogen on the Performance of Proton Exchange Membrane Fuel Cell (수소연료 중의 메탄에 의한 고분자전해질 연료전지 성능변화 연구)

  • Seo, Jung-Geun;Kwon, Jun-Taek;Kim, Jun-Bum;Chung, Jong-Tae;Kim, Woo-Sik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.4
    • /
    • pp.432-438
    • /
    • 2007
  • The reforming process for hydrogen production generates some impurities. Impurities in hydrogen such as $CO_2$, CO, $H_2S$, $NH_3$ affect fuel cell performance. It is well known that CO generated by the reforming process may negatively affect performance of cell, cause damage on catalysts resulting performance degradation. Hydrogen produced by reforming process includes about 2% methane. The presence of methane up to 10% is reported negligible degradation in cell performance. However, methane more than 10% in hydrogen stream had not been researched. The concentration of impurity supplied to the fuel cell was verified by gas chromatography(GC). In this study, the influence of $CH_4$ on performance of PEM fuel cell was investigated by means of current vs. potential experiment, long run(10 hr) test and electrochemical impedance measurement when the concentrations of impurities were 10%, 20% and 30%.

Performance Degradation of Mea with Cation Contamination in Polymer Electrolyte Membrane Water Electrolysis (고분자 전해질막 수전해 막전극접합체의 양이온 오염에 따른 성능 저하)

  • JUNG, HYEYOUNG;CHOI, NAKHEON;IM, SUHYUN;YOON, DAEJIN;MOON, SANGBONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.331-337
    • /
    • 2017
  • Proton Exchange Membrane Water Electrolysis (PEMWE) is one of the most popular and widely used methods for hydrogen production. PEMWE contributes to eco-friendly system via its energy storage system application, hence making it environmentally friendly to use. However, its main drawback is contamination of proton exchange membrane during water electrolysis. Existing cation such as magnesium, calcium and the likes are the cause for membrane contamination. As a result, the cation contamination give rise to degradation of performance of electrolysis and the reverse electrolysis is effective method to remove cation.

Effects of Electrical Stress on Polysilicon TFTs with Hydrogen passivation (다결정 실리콘 박막 트랜지스터의 수소화에 따른 전기적 스트레스의 영향)

  • Hwang, Seong-Soo;Hwang, Han-Wook;Kim, Dong-Jin;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1315-1317
    • /
    • 1998
  • We have investigated the effects of electrical stress on poly-Si TFTs with different hydrogen passivation conditions. The amounts of threshold voltage shift of hydrogen passivated poly-Si TFTs are much larger than those of as-fabricated devices both under the gate bias stressing and under the gate and drain bias stressing. Also, we have quantitatively analized the degradation phenomena using by analytical method. we have suggested that the electron trapping in the gate dielectric is the dominant degradation mechanism in only gate bias stressed poly-Si TFT while the creation of defects in the poly-Si is prevalent in gate and drain bias stressed device.

  • PDF

KINETICS OF ATRAZINE OXIDATION BY UV RADIATION AND OXALATE ASSISTED H2O2/UV PROCESSES

  • Choi, Hyun-Jin;Choi, Jong-Duck;Kim, Hyun-Kab;Lee, Tae-Jin
    • Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.28-32
    • /
    • 2006
  • The degradation of atrazine was explored using UV alone, $H_2O_2/UV$, oxalate/UV and oxalate-assisted $H_2O_2/UV$. The addition of oxalate to the $H_2O_2/UV$ (oxalate-assisted $H_2O_2/UV$) process was the most effective method for the degradation of atrazine. The overall kinetic rate constant was split into the direct oxidation due to photolysis and that by the radicals from hydrogen peroxide or oxalate. In semi-empirical terms, the initial concentration of hydrogen peroxide had a greater contribution than that of oxalate for atrazine oxidation.

Effects of Electrical Stress on Hydrogen Passivated Polysilicon Thin Film Transistors (다결정 실리콘 박막 트랜지스터에서의 수소화에 따른 전기적 스트레스의 영향)

  • Kim, Yong-Sang;Choi, Man-Seob
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1502-1504
    • /
    • 1996
  • The effects of electrical stress in hydrogen passivated and as-fabricated poly-Si TFT's are investigated. It is observed that the charge trapping in the gate dielectric is the dominant degradation mechanism in poly-Si TFT's which has been stressed by the gate bias alone while the creation of defects in the poly-Si film is prevalent in gate and drain bias stressed devices. The degradation due to the gate bias stress is dramatically reduced with hydrogenation time while the degradation due to the gate and drain bias stress is increased a little. From the experimental results, it is considered that hydrogenation suppress the charge trapping at gate dielectrics as well as improve the characteristics of poly-Si TFT's.

  • PDF

Fenton Degradation of Highly Concentrated Fe(III)-EDTA in the Liquid Waste Produced by Chemical Cleaning of Nuclear Power Plant Steam Generators (펜톤 반응을 이용한 원전 증기발생기 화학세정 폐액의 고농도 Fe(III)-EDTA 분해)

  • Jo, Jin-Oh;Mok, Young Sun;Kim, Seok Tae;Jeong, Woo Tae;Kang, Duk-Won;Rhee, Byong-Ho;Kim, Jin Kil
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.552-556
    • /
    • 2006
  • An advanced oxidation process catalyzed by iron ions in the presence of hydrogen peroxide, the so-called Fenton's reaction, has been applied to the treatment of steam generator chemical cleaning waste containing highly concentrated iron(III)- ethyl-enediaminetetraaceticacid (Fe(III)-EDTA) of 70000 mg/L. The experiments for the degradation of Fe(III)-EDTA were carried out not only with a simulated waste, but also with the real one. The effect of pH and the amount of hydrogen peroxide added to the waste on the degradation was examined, and the results were discussed in several aspects. The optimal pH to maximize the degradation efficiency was dependent on the amount of hydrogen peroxide added to the waste. i.e., when the amount of hydrogen peroxide was different, maximum degradation efficiency was obtained at different pH's. The optimal amount of hydrogen peroxide relative to that of Fe(III)-EDTA was found to be 24.7 mol ($H_{2}O_{2}$)/mol (Fe(III)-EDTA) at pH around 9.

Effect of Compensation for Thickness Reduction by Chemical Degradation of PEMFC Membrane on Performance and Durability (PEMFC 고분자막의 화학적인 열화에 의한 두께 감소 보정이 성능 및 내구성에 미치는 영향)

  • Sohyeong Oh;Yoojin Kim;Seungtae Lee;Donggeun Yoo;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.62 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • As the demand for hydrogen electric vehicles for commercial vehicles increases, the durability of PEMFCs must increase more than five times that of passenger cars, so research and development to improve durability is urgent. When the PEMFC membrane electrode assembly (MEA) undergoes chemical degradation, the MEA thickness decreases and pinholes occur. In this study, changes in the performance and durability of the MEA were measured while increasing the clamping pressure of the unit cell after open circuit voltage (OCV) holding, an accelerated chemical degradation experiment. As the clamping pressure increased, the resistance of the polymer membrane and the membrane/electrode contact resistance decreased, improving the I-V performance and reducing the hydrogen permeability. As the hydrogen permeability decreased, the OCV increased. When the pinhole area was removed and the MEA clamping pressure was increased, the hydrogen permeability decreased sharply, confirming that the local degradation has a large effect on the performance and durability of the entire cell. When the pinhole was removed and re-clamping and OCV holding was evaluated, it was confirmed that the durability improved according to the decrease in membrane resistance and hydrogen permeability.

Optimization of Condensate Water Drain Logic Depending on the Characteristics of Drain Valve in FPS of Fuel Cell Vehicle and Development of Anode Water Management Strategy to Achieve High Fuel Efficiency and Operational Stability (연료전지 자동차 내 수소 공급 시스템에서 드레인 밸브 특성에 따른 드레인 로직 최적화 및 연비와 운전안정성을 고려한 물 관리 전략 개발)

  • AHN, DEUKKUEN;LEE, HYUNJAE;SHIM, HYOSUB;KIM, DAEJONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.155-162
    • /
    • 2016
  • A proton exchange membrane fuel cell (PEMFC) produces only water at cathode by an electrochemical reaction between hydrogen and oxygen. The generated water is transported across the membrane from the cathode to the anode. The transported water collected in water-trap and drained to the cathode within the humidifier outlet. If the condensate water is not being drained at the appropriate time, condensate water in the anode can cause the performance degradation or fuel efficiency degradation of fuel cell by the anode flooding or unnecessary hydrogen discharge. In this study, we proposed an optimization method of condensate water drain logic for the water drain performance and the water drain algorithm as considered the condensate water generating speed prep emergency case. In conclusion, we developed the water management strategy of fuel processing system (FPS) as securing fuel efficiency and operating stability.