• 제목/요약/키워드: Hospital medical devices

검색결과 306건 처리시간 0.029초

Embolization of the Device to the Left Pulmonary Artery after the Interventional Closure of Ruptured Sinus of Valsalva Aneurysm

  • Choudhry, Lalit Kumar;Rao, Vinay M;Gnanamuthu, Birla Roy;Agrawal, Vishal;Shankar, Ravi;Prasath, Ram
    • Journal of Chest Surgery
    • /
    • 제48권3호
    • /
    • pp.202-205
    • /
    • 2015
  • Formation of an aneurysm in the sinus of Valsalva of the aortic root is usually due to an area of congenital weakness in its wall. This aneurysm may progressively dilate and rupture into any of the cardiac chambers or into the pericardial cavity. Though this is conventionally treated by surgery, interventional therapy using various closure devices is becoming more common. Embolization of these closure devices may occur. We report a case of embolization of such a device into the left pulmonary artery which during surgical retrieval, unmasked the hidden ventricular septal defect (VSD). Therefore one has to be cautious while making a diagnosis of rupture of the sinus of Valsalva of right coronary sinus without VSD.

Does Second-Generation Suspensory Implant Negate Tunnel Widening of First-Generation Implant Following Anterior Cruciate Ligament Reconstruction?

  • Sundararajan, Silvampatti Ramasamy;Sambandam, Balaji;Singh, Ajay;Rajagopalakrishnan, Ramakanth;Rajasekaran, Shanmuganathan
    • Knee surgery & related research
    • /
    • 제30권4호
    • /
    • pp.341-347
    • /
    • 2018
  • Purpose: Tunnel widening following anterior cruciate ligament (ACL) reconstruction is commonly observed. Graft micromotion is an important contributing factor. Unlike fixed-loop devices that require a turning space, adjustable-loop devices fit the graft snugly in the tunnel. The purpose of this study is to compare tunnel widening between these devices. Our hypothesis is that the adjustable-loop device will create lesser tunnel widening. Materials and Methods: Ninety-eight patients underwent ACL reconstruction from January 2013 to December 2014. An adjustable-loop device was used in 54 patients (group 1) and a fixed-loop device was used in 44 patients (group 2). Maximum tunnel widening at 1 year was measured by the L'Insalata's method. Functional outcome was measured at 2-year follow-up. Results: The mean widening was 4.37 mm (standard deviation [SD], 2.01) in group 1 and 4.09 mm (SD, 1.98) in group 2 (p=0.511). The average International Knee Documentation Committee score was 78.40 (SD, 9.99) in group 1 and 77.11 (SD, 12.31) in group 2 (p=0.563). The average Tegner-Lysholm score was 87.25 (SD, 3.97) in group 1 and 87.29 in group 2 (SD, 4.36) (p=0.987). There was no significant difference in tunnel widening and functional outcome between the groups. Conclusions: The adjustable-loop device did not decrease the amount of tunnel widening when compared to the fixed-loop device. There was no significant difference in outcome between the two fixation devices. Level of Evidence: Level 3, Retrospective Cohort.

동물병원 방사선 안전관리체계에 대한 연구 (Study of Radiation Safety Management of Veterinary Hospital in Korea)

  • 채수영;최호정;이영원
    • 한국임상수의학회지
    • /
    • 제37권1호
    • /
    • pp.15-22
    • /
    • 2020
  • This study investigated the effectiveness of radiation safety rules in animal hospital and the awareness and behavior of veterinary radiation workers. With the questionnaires, the data was collected from randomly selected veterinarians in animal hospitals and animal medical imaging centers. Collected data were about radiation device, shielding device, regulations, safety management, education, knowledge, behavior and awareness. Frequency, correlation and multiple regression analysis were performed. The medical devices related with radiation in animal hospital were X-ray (59%), CT (15%), fluoroscopy (12%), mobile X-ray (12%) and others (2%). The number of people using radiation shielding device is high. The answers were low on knowing radiation related regulation and receiving radiation protection education. The group with higher knowledge and awareness shows positive correlation with safety behavior. The increase of use of the radiation related medical devices in veterinary hospital causes the increase of radiation exposure risk. This study suggests that radiation safety management system and policies need to be developed to protect radiation workers and give them correct information and consciousness.

Biometry of width between labial transitional line angles in anterior teeth: an observational study

  • Wen, Chao;Ye, Hongqiang;Chen, Hu;Zhou, Yongsheng;Huang, Mingming;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.1-11
    • /
    • 2022
  • PURPOSE. The maximum width between the mesial and distal labial transitional line angles, described as "esthetic width" herein, could significantly influence the visual perception of the teeth and smile. This study aimed to conduct biometric research on esthetic width and to explore whether regular distribution exists in the esthetic width of human teeth. MATERIALS AND METHODS. A total of 4,264 maxillary and mandibular anterior teeth were measured using the Geomagic studio software program. The proportions of maxillary to mandibular homonymous teeth and proportions between the adjacent teeth were calculated. Bilateral symmetry and the correlation between the esthetic and mesiodistal widths were both accounted for during the measurement procedures. RESULTS. The mean esthetic widths were 6.773 ± 0.518 mm and 4.329 ± 0.331 mm for maxillary and mandibular central incisors, respectively, 5.451 ± 0.487 mm and 5.008 ± 0.351 mm for maxillary and mandibular lateral incisors, respectively, and 3.340 ± 0.353 mm and 5.958 ± 0.415 mm for maxillary and mandibular canines, respectively. Except for the mandibular canines, no significant difference in esthetic width was found among homonymous teeth from the same jaw. A high linear correlation was found between the esthetic and mesiodistal widths of the same tooth, except for the maxillary canines. Esthetic width proportions among different tooth categories showed some regular patterns, which were similar to those of the mesiodistal width. CONCLUSION. Esthetic width is regularly distributed among the teeth in the Chinese population. This could provide an important reference for anterior dental restorations and dimension recovery in esthetic reconstruction of anterior teeth.

의료용 침대 및 수술대의 기준규격 연구 (A Study on Standards for Hospital Bed and Operating Table)

  • 박상건;문인혁
    • 재활복지공학회논문지
    • /
    • 제3권1호
    • /
    • pp.35-40
    • /
    • 2009
  • 전동 조절식 의료용 침대나 수술대는 병원에서 환자의 요양시 또는 진료시 자세유지에 사용되는 유용한 기기이지만, 다양한 기능과 복잡한 기구 메커니즘으로 인해 사용상의 안전사고가 빈번하게 발생하는 의료기기의 하나이다. 본 논문에서는 의료기기로서 승인이 필요한 의료용 침대와 수술대의 안전성과 성능에 관한 일반 요구사항 및 시험방법을 제시한다. 각 항목은 관련 국제규격을 바탕으로 구성한다. 연구의 결과는 식품의약품안전청의 의료기기 인허가시 적용되는 기준규격의 개발에 사용될 수 있다.

  • PDF

Transcatheter closure of small ductus arteriosus with amplatzer vascular plug

  • Cho, Eun Hyun;Song, Jinyoung;Kang, I-Seok;Huh, June;Lee, Sang Yoon;Choi, Eun Young;Kim, Soo Jin
    • Clinical and Experimental Pediatrics
    • /
    • 제56권9호
    • /
    • pp.396-400
    • /
    • 2013
  • Purpose: The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP). Methods: We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated by performing angiograms, and the PDA size and the AVP devices size were compared. Results: The mean age of the patients was $54.9{\pm}45.7$ months old. The PDAs were of type C (n=5), type D (n=12), and type E (n=3). The mean pulmonary end diameter of the PDA was $1.7{\pm}0.6$ mm, and the aortic end diameter was $3.6{\pm}1.4$ mm. The mean length was $7.3{\pm}1.8$ mm. We used 3 types of AVP devices: AVP I (n=5), AVP II (n=7), and AVP IV (n=8). The ratio of AVP size to the pulmonary end diameter was $3.37{\pm}1.64$, and AVP size/aortic end ratio was $1.72{\pm}0.97$. The aortic end diameter was significantly larger in those cases repaired with AVP II than in the others (P=0.002). The AVP size did not significantly correlate with the PDA size, but did correlate with smaller ratio of AVP size to aortic end diameter ($1.10{\pm}0.31$, P=0.032). Conclusion: Transcatheter closure of small PDA with AVP devices yielded satisfactory outcome. AVP II was equally effective with smaller size of device, compared to others.

병원복을 위한 UFC(Ubiquitous Fashionable Computer) 디자인 (Ubiquitous Fashionable Computer Design for Hospital Clothing)

  • 강정민;하지수
    • 한국의류학회지
    • /
    • 제31권5호
    • /
    • pp.717-728
    • /
    • 2007
  • The purpose of this study is to suggest hospital clothing design which reflects ubiquitous info-communications technology as changing hospital environment in the information-oriented era of the 21st century. The methods of this study are documentary research of previous studies, observation research and deep interviews. Seoul national university hospital is selected as a target of observation for this study. Doctors, nurses, pharmacists, and patients who are the representative jobs in the hospital are interviewed from on July, 13, 2006 to on August, 1, 2006. According to observation research, the computers, OCR, and PACS are applied from registration to dosage through all courses of diagnosis. However, the most inconvenient problems to patients are the location of medical offices and confusion of reservation. Also, the needs and inconveniences of doctors, nurses, pharmacists, and patients are almost solved by using RFID technology as a result of deep interviews. They prefer wearing devices as an accessory to wearing devices as a clothing directly. In conclusion, suggested UFC design for hospital clothing with info-communications technology promotes efficiency, accuracy, convenience of work to medical personnel in changing hospital environment as the flow of the information-oriented era of the 21st century.

의료기기 발전과 신의료기술평가 규제혁신 (Advanced medical devices and regulatory innovations in new health technology assessments)

  • 이유경
    • 대한의사협회지
    • /
    • 제61권12호
    • /
    • pp.702-705
    • /
    • 2018
  • Advances in technology lead to advances in medical devices, and these advances have the positive effect of creating opportunities for beneficial developments in healthcare, such as innovating traditional healthcare processes or expanding opportunities for diagnosing and treating diseases. Nonetheless, device developers, suppliers, users, insurers, and patients all face the challenge of balancing patient safety and health effectiveness with a reasonable profit. In Korea, the New Health Technology Assessment system aims to introduce safe and effective health technology, but this is only effective for the entry of devices onto the healthcare market. This system is not enough for creating a healthy ecosystem in which high-quality technologies and devices survive in the market and naturally exit from the market if not successful. The nation must not lag in the rapid development of medical devices, but the concomitant requirement for patient safety is like two rabbits moving in different directions. There is not enough time to resolve each source of uncertainty for both developers and users. The early adoption of health technologies, including medical devices, offers new opportunities for treatment and diagnosis, but also poses unexpected health risks. Thus, we need to design a plan to generate scientific evidence related to medical devices after they introduced into practice. Additionally, regarding the use of individual medical devices, we believe that the creation of a healthy ecosystem for medical devices by implementing medical device surveillance culture is a way to manage the opportunities and risks of the early introduction of innovative medical devices.

커넥티드 의료기기 해킹 및 랜섬웨어 대응기술 동향 (Security Technology Trends to Prevent Medical Device Hacking and Ransomware)

  • 권혁찬;정병호;문대성;김익균
    • 전자통신동향분석
    • /
    • 제36권5호
    • /
    • pp.21-31
    • /
    • 2021
  • Ransomware attacks, such as Conti, Ryuk, Petya, and Sodinokibi, that target medical institutions are increasing rapidly. In 2020, in the United States., ransomware attacks affected over 600 separate clinics, hospitals, and organizations, and more than 18 million patient records. The cost of these attacks is estimated to be almost $21 billion USD. The first death associated with a ransomware attack was reported in 2020 by the University Hospital of Düesseldorf in Germany. In the case of medical institutions, as introduced in the Medjack report issued by TrapX Labs, in many cases, attackers target medical devices that are relatively insecure and then penetrate deep into more critical network infrastructure, such as EMR servers. This paper introduces security vulnerabilities of hospital medical devices, considerations for ransomware response by medical institutions, and related technology trends.

The use of mobile computing devices in microsurgery

  • Pafitanis, Georgios;Hadjiandreou, Michalis;Miller, Robert;Mason, Katrina;Theodorakopoulou, Evgenia;Sadri, Amir;Taylor, Kirsten;Myers, Simon
    • Archives of Plastic Surgery
    • /
    • 제46권2호
    • /
    • pp.102-107
    • /
    • 2019
  • Mobile computing devices (MCDs), such as smartphones and tablets, are revolutionizing medical practice. These devices are almost universally available and offer a multitude of capabilities, including online features, streaming capabilities, high-quality cameras, and numerous applications. Within the surgical field, MCDs are increasingly being used for simulations. Microsurgery is an expanding field of surgery that presents unique challenges to both trainees and trainers. Simulation-based training and assessment in microsurgery currently play an integral role in the preparation of trainee surgeons in a safe and informative environment. MCDs address these challenges in a novel way by providing valuable adjuncts to microsurgical training, assessment, and clinical practice through low-cost, effective, and widely accessible solutions. Herein, we present a review of the capabilities, accessibility, and relevance of MCDs for technical skills acquisition, training, and clinical microsurgery practice, and consider the possibility of their wider use in the future of microsurgical training and education.