• 제목/요약/키워드: High voltage apparatus

검색결과 146건 처리시간 0.023초

플라즈마 이온주입에서 쉬스 동역학에 관한 연구 (Study of Sheath Dynamics in Plasma Source Ion Implantation)

  • 김광훈;조주현;최영욱;이홍식;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1797-1799
    • /
    • 1998
  • Plasma source ion implantation(PSII) is a non-line-of-sight technique for surface modification of materials which is effective for non-planar targets. A apparatus of 30kV PSII is established and plasma characteristics are diagnosed by using a Langmuir probe. A spherical target is immersed in argon plasma and biased negatively by a series of high voltage pulses. Sheath evolution is measured by using a Langmuir probe and compared with the result of computer simulations.

  • PDF

공기중 코로나방전의 초음파신호 특성 (Ultrasonic Signal Characteristics of Corona Discharges in Air)

  • 이상우;김인식;이광식;이동인;이동헌;배상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1702-1704
    • /
    • 1998
  • In order to establish the usefulness of ultrasonic techniques for detecting corona discharges in high-voltage power apparatus, it is first necessary to determine the relationship between electrical and ultrasonic signals of corona discharges in air. In this paper, various characteristics of ultrasonic signal detection for point-to-plane corona discharges using a 200[kHz] ultrasonic sensor are examined. In regard to the attenuation and directivity of ultrasonic signals, the signals were inversely proportional to the distance between corona sources and ultrasonic receiving sensors, and half attenuation angles were approximately 7.0 degree. Ultrasonic signals of positive polarities were first obserbed at corona inception voltages. and the signals were increased with increasing the applied voltages.

  • PDF

MCS에 의한 Helium 기체 중의 전자수송특성 해석 (Analysis of electron transport characteristic in He gas by MCS)

  • 송병두;하성철;서상현;문기석;유회영;김상남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1752-1754
    • /
    • 1998
  • Recently the research about electron transport characteristic and energy distribute function in mixture gases within Helium, has been used and developed widely as industrial quality improvement of extinguish characteristic, electrical dielectric strength ability of application of each species high voltage apparatus, gas plasma etching progress of work to use manufacture of semiconductor, thin film molding by CVD, insulation film to use ultra LSI, etc. This paper analyze electron transport characteristic in the range E/N $1{\sim}60$[Td], pressure $0.1{\sim}6.0$[Torr] by MCS. It is necessary to seek electron drift velocity, diffusion coefficient, lonization coefficients, characteristic energy, mean energy and electron energy distribution function as electron transport characteristic.

  • PDF

네트워크 최적화 기법에 의한 고압지중배전계통 계획 (A Planning on the high voltage underground distribution line using optimization technique)

  • 최상봉;김대경;정성환;김병숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1044-1047
    • /
    • 1997
  • This paper presents development of practical and universal program that is applied to ${\pi}$ loop system which is based on basic algorithm of network optimization for reduction investment cost and rationalization of underground plan. This system is ease to input and modify about information of powerline drawing, that is, can input easily condition of their calculation referring to candidate of underground apparatus under using digitizer.

  • PDF

FEM을 이용한 가스차단기의 아크해석 (Arc Simulation of GCB Interrupter Using FEM)

  • 무징웨이;박경엽;정진교;최영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.345-348
    • /
    • 1999
  • An arc model based on the N-S equations modified by adding an energy source term to take account of the arc is developed and solved using Taylor-Garlerkin FEM in the present paper. The numerical method is applied to the simulation of the opening procedure of a puffer type GCB. Moving boundary conditions of the arc chamber during operation is taken into account. Numerical predictions of the temperature profiles at different strokes are presented.

  • PDF

COMPUTER SIMULATION OF ARC INTERRUPTION USING FEM FOR $SF_6$ GAS CIRCUIT BREAKERS

  • Park, K.Y.;Chong, J.K.;Song, K.D.;Lee, B.Y.;Mu, J.W.
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.68-73
    • /
    • 2000
  • An arc model based on the N-S equations modified by adding an energy source term to take account of the arc is developed and solved using Taylor-Galerkin FEM. The numerical method is applied to the simulation of the interruption process of a puffer type GCB. Moving boundary conditions of the arc chamber during operation is taken into account. The thermal interruption capability of an actual puffer type GCB will be predicted and compared with that of the measured result.

  • PDF

대두유 에스테르계 절연유의 합성과 분석 (Study on the synthesis and characterization of soybean based transformer oils)

  • 한동희;조한구;한세원;안명상;오대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.244-245
    • /
    • 2005
  • Electrical insulation is one of the most important parts in a high voltage apparatus. Traditionally mineral oils and synthetic esters have been widely used as dielectric coolants for power transformers. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. This paper reports on the synthesis and characterization of soybean based ester oils. Two different types of soybean based transformer oils, named as methyl ester and isopropyl ester were synthesized. The synthesis of these esters was achieved by transesterification reactions of soybean oil and alcohol in the presence of catalyst. The GC and NMR spectroscopic analysis of the esters have been performed. The thermal stability of the esters was determined by thermal gravimetric analysis(TGA).

  • PDF

방사선 검출기 적용을 위한 액정 기반 다층 구조의 광 특성 평가 (The optical characteristics study of sandwich structure based liquid crystal for the radiation detector application)

  • 신정욱;강상식;박지군;조성호;차병열;김진영;이건환;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.390-392
    • /
    • 2005
  • The digital radiation detectors are used clinically by diagnostic apparatus. However the digital radiation detector are some problem like high operating voltage, light blurring, low conversion efficiency, low fill factor, etc. Thus we propose a new radiation detector that the photoconductor layer and liquid crystal layer are coupled in sandwich structure. X-ray absorption in the photoconductor layer controls the state of the liquid crystal via creation of charge carrier and the light modulation of liquid crystal make image formation. The advantage of the new radiation detector is that high resolution image is acquired and the signal amplification is possible by external visible light source. In this study, we study the optical properties and electrical properties of the new radiation detector to irradiate X-ray. The Mercury Iodide($HgI_2$) was used by photoconductor material, and the aluminum is used by reflective layer. The thickness of Mercury Iodide is about $200{\mu}m$, the operating voltage of the liquid crystal is 1.5~5V. The electrical properties of Mercury Iodide was measured, and the transmission efficiency of liquid crystal was measured by modulation potential.

  • PDF

초고압 GCB의 차단성능 검증을 위한 유동해석 (Fluid Analysis for Verifying Interrupting Capability of UHV GCB)

  • 김두성;서경보;송원표;정영환;김덕수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.19-21
    • /
    • 2002
  • Recently, it has become more competitive to take larger market share among domestic companies manufacturing high-power apparatus. Unfortunately, the size of total market in this field is being smaller than before because the business of transmission and distribution of electric power is being shifted from government control to private management. To save this situation, we are trying to develop new high-voltage Gas Insulated Switchgear for export such as 245kV GIS and 300kV GIS. It is very important to make GIS compact size to have international competitiveness against European companies. By reducing GIS's dimensions same as 170kV class, we expect to launch abroad successfully. Many factors should be considered to achieve good performance during short-circuit making-breaking. Analysis on cold gas flow is one method widely used to evaluate small-current interruption. Through this analysis, we can examine the dielectric characteristics at the weak points in the circuit-breaker. In this paper, we describe the results of cold-gas flow analyses on 245kV and 300kV circuit-breakers.

  • PDF

PC 펠렛의 마이크로웨이브 건조를 위한 에너지 효율 분석 (Analysis of Energy Consumption for Microwave Drying in PC Pellet)

  • 이현민;김재경;전의식
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.44-48
    • /
    • 2021
  • Semiconductor inspection equipment makes components using materials with insulating properties for functional inspection including current and voltage of semiconductor parts. A representative insulating material is plastic, and plastic is made of a component through an injection process using plastic pellet. When plastic pellets contain excessive moisture, problems such as performance degradation and product surface defects occur. To prevent this, pre-drying is essential, and the heat convective type is the most applied. However, the heat convective type has a problem of low consumption efficiency and a long drying time. Recently, many studies have been conducted on a drying method using microwaves due to high energy efficiency. In this paper, drying was performed using a microwave for drying PC pellets. Energy consumption and drying efficiency analyzed by set up an experimental apparatus of heat convective, microwave, and hybrid(heat convective + microwave) types. It was confirmed that energy consumption and drying efficiency were high when drying using microwaves, and it was confirmed that the hybrid method improved drying performance compared to the heat convective method. It is expected that the research results of this paper can be used as basic data for drying plastic pellets using microwave.