• Title/Summary/Keyword: High power electromagnetic

Search Result 954, Processing Time 0.037 seconds

Current Characteristics of CMOS device Broken by Intentional High Power Electromagnetic Wave (의도 고출력 전자파에 의해 오동작 되는 CMOS소자의 전류특성)

  • Hwang, Sun-Mook;Hong, Joo-Il;Han, Seung-Mook;Park, Shin-Woo;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1516-1517
    • /
    • 2007
  • This paper investigated the breakdown effect of the CMOS device by impact of high power electromagnetic wave. The experiments employed a waveguide to study the current characteristics of CMOS device broken by high power electromagnetic wave. The CMOS device were composed of a LED drive circuit for visual discernment. Also CMOS device broken by high power electromagnetic wave was observed by power current. The CMOS device were broke by high power electromagnetic wave at about 10 kV/m and when power current is 75 mA. Based on the result, CMOS devices should show plan to protect the CMOS devices by high power electromagnetic wave. And the database from this experiment should provide the basis for future investigation.

  • PDF

The Destruction Effects of Semiconductors by High Power Electromagnetic Wave (고출력 과도전자파에 의한 반도체 소자의 파괴효과)

  • Hwang, Sun-Mook;Hong, Joo-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1638-1642
    • /
    • 2007
  • This paper investigated the destruction effect of the semiconductors by impact of high power electromagnetic wave. The experiments is employed as an open-ended waveguide to study the destruction effects on semiconductor using a 2.45 GHz 600 W Magnetron as a high power electromagnetic wave. The semiconductors are located at a distance of $31cm\sim40cm$ from the open-ended waveguide and are composed of a LED drive circuit for visual discernment. Also the chip condition of semiconductor is observed by SEM(Scanning Electron Microscope) analysis. The semiconductor are damaged by high power electromagnetic wave at about 860 V/m. The SEM analysis of the destructed devices showed onchipwire and bondwire destructions. Based on the result, semiconductor devices should have plan to protect the semiconductor devices form high power electromagnetic wave. And the database from this experiment provides the basis for future investigation.

Electromagnetic Interference Analysis of an Inhomogeneous Electromagnetic Bandgap Power Bus for High-Speed Circuits

  • Cho, Jonghyun;Kim, Myunghoi
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.4
    • /
    • pp.237-243
    • /
    • 2017
  • This paper presents an analysis of the electromagnetic interference of a heterogeneous power bus where electromagnetic bandgap (EBG) cells are irregularly arranged. To mitigate electrical-noise coupling between high-speed circuits, the EBG structure is placed between parallel plate waveguide (PPW)-based power buses on which the noise source and victim circuits are mounted. We examine a noise suppression characteristic of the heterogeneous power bus in terms of scattering parameters. The characteristics of the dispersion and scattering parameters are compared in the sensitivity analysis of the EBG structure. Electric field distributions at significant frequencies are thoroughly examined using electromagnetic simulation based on a finite element method (FEM). The noise suppression characteristics of the heterogeneous power bus are demonstrated experimentally. The heterogeneous power bus achieves significant reduction of electrical-noise coupling compared to the homogeneous power buses that are adopted in conventional high-speed circuit design. In addition, the measurements show good agreement with the FEM simulation results.

Estimation of Damage in Electric Power Networks due to High Power Electromagnetic Pulse (고출력 전자기파에 대한 전력망 피해 비용 산출)

  • Hyun, Se-Young;Du, Jin-Kyoung;Kim, Wooju;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.757-766
    • /
    • 2014
  • In this paper, economic loss due to high power electromagnetic pulse is estimated and the methodology used for calculating its impacts is suggested using a macro approach. In order to investigate the most critical infrastructure for the high power electromagnetic pulse assault, the vulnerability assessment that provides information on the threats of concern is conducted. As a result, this study concentrates on the electric power networks. The presented assessment model is considered with gross domestic product (GDP) and energy consumption when the electric power networks are damaged due to high power electromagnetic pulse. In addition, economic losses are calculated by the extent of damages considering different types of the high power electromagnetic pulse assault generated by nuclear and man-made weapon. Through the estimation of these damages, the resulted economic loss will be compared with the protection cost. Consequently, protection of the vulnerable infrastructures can be prepared against electromagnetic pulse attack.

Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment (전자파 검출에 의한 전력기기 On-Line 열화 측정시스템 개발)

  • Kang, C.W.;Choi, G.S.;Lee, Y.S.;Kim, C.W.;Kang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1664-1666
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment in enclosed switchboard (전자파를 이용한 폐쇄배전반내 전력기기의 열화 온라인 진단시스템 개발)

  • Kang, C.W.;Choi, G.S.;Lee, Y.S.;Kang, D.S.;Kim, J.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.178-181
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

Development of electromagnetic wave detecting equipment for diagnosis of partial discharge in enclosed switchboard (폐쇄 배전반에서의 부분 방전 On-Line 열화 감시 시스템 개발)

  • Jun, K.H.;Kang, C.W.;Kim, J.C.;Kim, K.H.;Kang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.318-320
    • /
    • 2000
  • This paper presents the develop-ment of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

  • Tourab, Wafa;Babouri, Abdesselam
    • Safety and Health at Work
    • /
    • v.7 no.2
    • /
    • pp.102-110
    • /
    • 2016
  • Background: This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Methods: Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. Results: The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

Reducing Electromagnetic Radiation in Split Power Distribution Network of High-Speed Digital System

  • Shim, Hwang-Yoon;Kim, Jiseong;Yook, Jong-Gwan;Park, Han-Kyu
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.340-343
    • /
    • 2002
  • Electromagnetic(EM) radiation problems and their possible solutions are addressed in this paper for the split power plane of high-speed digital systems. Stitching and decoupling capacitors are proved to be very effective fur reducing signal noise, ground bounce as well as electromagnetic radiation from the split power plane. Simulations based on 3D-Finite Difference Time Domain (FDTD) method are utilized for the analysis of practical high frequency multi-layered PC main board

  • PDF

Exposure limits of Magnetic fields of High Voltage Transmission lines for Evaluation of Environmental Impact (고압선로 환경영향평가의 자기장 노출범위설정에 관한 연구)

  • Jeon, In-Soo
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.5
    • /
    • pp.243-250
    • /
    • 2004
  • Recently, concerns about health risks exposed to electromagnetic fields have been brought in the safety of electric power lines. A number of governmental and international organizations have advised to avoid the magnetic field exposure to the schools and residential areas. Some epidemiologic studies showed that electromagnetic fields should not exceed the exposure limits of 2-3mG to the people living near high-voltage transmission lines. In this study, the principles, ranges and survey methods of the assessment for powerfrequency electromagnetic fields were reviewed from the relevant research papers and documents. The ranges of electromagnetic fields were determined from 50m to 100m and have been defined according to the properties of each electric power lines and a new methodology was suggested in this study. It would be necessary to develop and improve specific assessment methods for various high-voltage transmission lines projects.