• Title/Summary/Keyword: High efficiency level

Search Result 1,878, Processing Time 0.029 seconds

Development of the Computer Program for Predicting the Aero-acoustic Performance in the Design Process of Axial Flow Fan (축류형 송풍기 설계 과정에서 공력-음향학적 성능 예측을 위한 전산 프로그램의 개발)

  • Chung, Dong-Kyu;Hong, Soon-Seong;Lee, Chan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.91-98
    • /
    • 2000
  • Developed is a computer program for the prediction of the aero-acoustic performance characteristics such as discharge pressure, efficiency, power and noise level in the basic design step of axial flow fan. The flow field and the aerodynamic performance of fan are analyzed by using the streamline curvature computing scheme with total pressure loss and flow deviation models. Fan noise is assumed to be generated due to the pressure fluctuations induced by wake vortices of fan blades and to radiate via dipole distribution. The vortex-induced fluctuating pressure on blade surface is calculated by combining thin airfoil theory and the predicted flow field data. The predicted aerodynamic performances, sound pressure level and noise directivity patterns of fan by the present computer program are favorably compared with the test data of actual fan. Furthermore, the present computer program is shown to be very useful in optimizing design variables of fan with high efficiency and low noise level and in analyzing their design sensitivities.

  • PDF

Operation-level Early Termination Algorithm for Inter-predictions in HEVC

  • Rhee, Chae Eun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.4
    • /
    • pp.235-242
    • /
    • 2016
  • The emerging High-Efficiency Video Coding (HEVC) standard attempts to improve coding efficiency by a factor of two over H.264/Advanced Video Coding (AVC) at the expense of an increase in computational complexity. Mode decision with motion estimation (ME) is still one of the most time-consuming computations in HEVC, as it is with H.264/AVC. Thus, fast mode decisions are not only an important issue to be researched, but also an urgent one. Several schemes for fast mode decisions have been presented in reference software and in other studies. However, the conventional hierarchical mode decision can be useless when block-level parallelism is exploited. This paper proposes operation-level exploration that offers more chances for early termination. An early termination condition is checked between integer and fractional MEs and between the parts of one partition type. The fast decision points of the proposed algorithm do not overlap those in previous works. Thus, the proposed algorithms are easily used with other fast algorithms, and consequently, independent speed-up is possible.

Adsorption and Desorption Characteristics of Methyl iodide on Silver ion-Exchanged Synthetic Zeolite at High Temperature

  • Park, Geun-Il;Park, Byung-Sun;Cho, Il-Hoon;Kim, Joon-Hyung;Ryu, Seung-Kon
    • Nuclear Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.504-513
    • /
    • 2000
  • The adsorption characteristics of methyl iodide generated from the simulated off-gas stream on various adsorbents such as silver ion-exchanged zeolite (AgX), zeocarbon and activated carbon were investigated. An extensive evaluation was made on the optimal silver ion-exchanged level for the effective removal of methyl iodide at temperature up to 38$0^{\circ}C$. The degree of adsorption efficiency of methyl iodide on silver ion-exchanged zeolite is strongly dependent of silver ion-amount and process temperature. The influence of temperature, methyl iodide concentration and silver ion-exchanged level on the adsorption efficiency is closely related to the pore characteristics of adsorbents. It would be facts that the effective silver ion-exchanged level was about 10 wt%, based on the degree of silver utilization for the removal of methyl iodide.

  • PDF

5-Level Inverter for Excitation Voltage Control of SRM (SRM의 여자전압제어를 위한 5-레벨 인버터)

  • Lee, S.H.;Park, S.J.;Ahn, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.294-296
    • /
    • 2000
  • Energy recovery in the regenerative region is very important when SRM(Switched Reluctance Motor) is used in traction drive. This is because that to reduce energy loss during mechanical braking and/or to have a high efficiency drive during braking. To control excitation voltage in motor operation and regenerative voltage in the generator operation in the SRM, multi-level voltage control is effective. This paper suggests multi-level inverter which is useful for motoring and regenerative operation in SRM.

  • PDF

The Analysis of the Discharging Characteristics on the Base Vacuum Level in a Vacuum In-line Sealing Process for High-efficiency PDP (고효율 PDP 제작을 위한 진공 인라인 실장에서의 초기 진공도에 따른 방전특성 분석)

  • Kwon Sang Jik;Jang Chan-Kyu;Kim Yong-Jae
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.57-63
    • /
    • 2006
  • We have examined the electrical and optical characteristics of the plasma display panel(PDP) produced by vacuum in-line sealing technology. We found that the luminous efficiency was decreased as the base vacuum level was increased. For the base vacuum level of $1\times10^{-3}$ Torr, the firing voltage was 235V at the discharge gas pressure of 400 Torr and the luminous efficiency was 0.8 lm/W at 180V sustaining pulse. However, for the base vacuum level of $1\times10^{-6}$ Torr, the firing voltage was reduced to 215V and the luminous efficiency was improved to 2.5lm/w. Finally, we demonstrated successfully the operation of tip-less PDP fabricated using vacuum in-line sealing method.

High Efficiency H-Bridge Multilevel Inverter System Using Bidirectional Switches (양방향 스위치를 이용한 고효율 H-Bridge 멀티레벨 인버터 시스템)

  • Lee, Hwa-Chun;Hwang, Jung-Goo;Kim, Sun-Pil;Choi, Woo-Seok;Lee, Sang-Hyeok;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.16-26
    • /
    • 2014
  • This paper proposes new 13-level inverter topology and DC/DC converter buck-boost structure topology for multilevel, compounding uni-directional and bi-directional switches, and proposes high-efficient multilevel inverter system in which the proposed two PCS(Power Conditioning System) was connected in series. In proposed multilevel inverter of forming a output 13-level phase voltage by using total 18 switching parts, Then bi-directional switch has a characteristic of reducing conduction loss and controlling the reactive power effectively by separating electrically from the neutral point. DC/DC converter for supplying in dependent 3 DC voltage to the proposed multi-level inverter generates 180-degree phase shifted PWM by the symmetrically combined structure of 2 buck-boost converter and twice switching frequency efficiency can be obtained, meanwhile, the converter can step up/down the output voltage and 20% output can be generated comparing the input voltage. This proposed system is verified with the simulation and laboratory test.

The Invert for ozone generator by mixed square_wave and PWM (구형파 및 PWM 인버터 조합에 의한 오존발생용 인버터)

  • Park Noh-Sik;Park Sung-Jun;Won Tae-Hyun;Ahn Jin-Woo;Kim Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1193-1195
    • /
    • 2004
  • Ozone gas is one of the strongest oxidizing and bleaching agents which leave no residues harmful to the global environment. In recent years, the ozone generator has been widely utilized, However, it has been known that a broader application of ozone is hindered primarily because of its low efficiency of generation. Thus, it is more indispensable to improve actual system efficiency of the silent discharge type ozonizer using high frequency inverter. This paper presents a multi level resonant ozone power regulation by association of high frequency transformers and full bridge invert. And proposed resonant inverter system can generate continuous output voltage. can control linearly quantity of ozone gas. This invert that add PWM forms within square forms of output voltage about one level range. The power regulation characteristics and operating performances of silent discharge (SD)type ozone generating tube load driven by this load proposed inverter using FET modules are illustrated from a practical point of view, which can operate under stable conditions of basic level and PWM hybrid control strategy implemented DSP(2406). The effectoveness of propsed invert type ozonizer is proved by experiment results.

  • PDF

Research on Efficiency of Western China's Universities under the "Double First-Class" Initiative ("더블 퍼스트 클래스"를 통한 중국 서부 대학의 연구 효율성에 관한 연구)

  • Youming Li;Jae-Yeon Sim
    • Industry Promotion Research
    • /
    • v.8 no.4
    • /
    • pp.257-266
    • /
    • 2023
  • The research focuses on the provincial universities in the western region of China and investigates the research level of 12 provincial universities from 2017 to 2021, considering both static efficiency and dynamic efficiency. The static efficiency is examined using Data Envelopment Analysis (DEA), while the dynamic efficiency is analyzed using the Malmquist model. The analysis results are as follows: the scientific research efficiency of universities in the 12 western provinces is generally not high. Against the background of the "Double First-Class" construction, the overall efficiency of scientific research in universities is showing an increasing trend. The main reason for the increase in scientific research efficiency is the increase in scale efficiency in recent years. The total factor productivity (TFP) of research activities is influenced by the technology progress index and exhibits a pattern of initial increase, followed by a decline, and then an increase again. Research conclusion: Western colleges and universities should reasonably allocate resources for scientific research activities, perfect scientific research mechanisms, improve management standards, promote scientific innovation and corresponding achievements, and ultimately raise the scientific and technological level in western China.

Trends in Indian Private Sector Bank Efficiency: Non-Stochastic Frontier DEA Window Analysis Approach

  • KUMAR, Ashish;ANAND, Nakul;BATRA, Vikas
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.729-740
    • /
    • 2020
  • The study examines the efficiency of private sector banks in India with the help of Window DEA (Data Envelopment Analysis) for a period from 2005 to 2017. With a window of three years, the period was divided into 11 windows. The study outcomes show that 59.9% of all private sector banks in India operate at more than 0.9 level of efficiency, and there are only three occasions when banks were operating at the efficiency value between 0.6 to 0.7. Further, the consistency in the efficiency scores of the banks has also been analyzed using an efficiency mapping matrix, and the mean efficiency score of the bank in each window is studied. The score of standard deviation was interpreted accordingly for these banks. Banks that are showing the highest efficiency scores also have a higher variance of efficiency scores. There was no bank identified in the matrix that promises high-efficiency ratings with low variability. The study concludes that the analysis of the efficiency mapping matrix indicates that, as a DMU escalates in the efficiency scores, the standard deviation reflecting the risk in overall efficiency scores also tends to rise. The findings complement the concept of higher risk to higher return or greater efficiency.

An Improved High Efficiency Resonant Converter for the Contactless Power Supply with a Low Coupling Transformer (낮은 커플링 변압기를 갖는 비접촉 전원의 개선된 고효율 공진 컨버터)

  • Kong Young-Su;Kim Eun-Soo;Lee Hyun-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.1
    • /
    • pp.33-39
    • /
    • 2005
  • Comparing with the conventional transformer without the air gap, a contactless transformer with the large air gap between the long primary winding and the secondary winding has increased leakage inductance and reduced magnetizing inductance. For transferring the primary power to the secondary one, the high frequency series resonant converter has been widely used for the contactless power supply system with the large air gap and the increased leakage inductance of the contactless transformer However, the high frequency series resonant converter has the disadvantages of the low efficiency and high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, the characteristics of the high efficiency and unit voltage gain are revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation based on the theoretical analysis and the 5kW experimental prototype.