• Title/Summary/Keyword: High Thermal Environment

Search Result 944, Processing Time 0.025 seconds

Inspection System of Coating Layers by Thermal Behavior Effect (열 거동 영향에 따른 코팅층 검사 시스템)

  • Yun, Sung-Un;Kim, Jae-Yeol;Choi, Seung-Hyun;Kim, Hang-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.1-7
    • /
    • 2014
  • Gas turbines for generation are operated under high temperatures, high pressures and in corrosive environments for long periods of time. This environment causes serious damage to these parts. Therefore, the material, coating, and cooling technology used with a gas turbine are important factors with regard to turbine blade development. One method that can be used to protect a product from harsh conditions is the coating technology. A turbine blade undergoes very aggressive thermal stress and experiences high-temperature fatigue. In order to reduce the surface temperature of the components and protect the blade from high-temperature flames, a thermal barrier coating (TBC) is applied to its substrate. This study confirms the applicability of an inspection system for the turbine blade coating layer using an artificial heat source.

Volatile Aroma Compounds of Several Domestic Thymus quinquecostatus by Thermal Desorption Gas Chromatograph Mass Spectrometer (열탁착식 가스크로마토질량분석기에 의한 국내 산지별 백리향의 휘발성향기성분)

  • Chiang, Mae-Hee;Lee, Kwang-Woo;Baik, Jung-Ae
    • Journal of Bio-Environment Control
    • /
    • v.20 no.1
    • /
    • pp.14-20
    • /
    • 2011
  • Objective of this research was to investigate the volatile aroma compounds and phenol contents for preservative effects. Aerial part of 5 Korean natured species of thyme located in Jeju alpine, jeju middle mountain, Kyeonggido, Ulleung island, and Gangwondo was analyzed by thermal desorption gas chromatograph mass spectrometer (TD-GC-MSD) method. Jeju middle mountain thyme was relatively high 62 species and has been investigated a high concentration of $7365.22{\mu}g/m^3$ contents according to the quantitative analysis. Total phenol contents containing thymol and carvacrol of Jeju middle mountain thyme were relatively high and showed 35.92%.

공력가열 시험설비 설계

  • Ok, Ho-Nam;Kim, In-Sun;Ra, Seung-Ho;Kim, Seong-Lyong;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.155-169
    • /
    • 2004
  • Space launch vehicles and reentry vehicles are exposed to extreme heating conditions due to high aerodynamic heating while flying at high Mach numbers in the atmosphere. To protect the vehicle itself or the payload from the aerodynamic heating, the thermal load imposed on the surface should be exactly predicted and proper thermal protection should be applied based on the prediction results. But this requires rigorous thermal analysis and testing to prevent loss of payload capacity caused by excessive heat shielding, and the amount of thermal protection material to be applied is determined through aerodynamic heating tests. Various design points to be considered to upgrade the prototype aerodynamic thermal simulation facility(ATSF) used for the KSR-series sounding rocket development to the one suitable for the KSLV(Korean Space Launch Vehicle)-series launch vehicle are considered in this research. The need and limitation for the facility are first considered, and the functions required for KSLV testing are determined. The specifications of the upgraded facility are briefly suggested and these results will be used for the future fabrication and installation of the facility.

  • PDF

Analysis on Thermal Structural Characteristics of Thermal Protection System Panel for a High-speed Vehicle (초고속 비행체 열방어 시스템 패널의 열구조 특성 분석)

  • Lee, Heesoo;Kim, Yongha;Park, Jungsun;Goo, Namseo;Kim, Jaeyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.942-944
    • /
    • 2017
  • High-speed vehicles are subjected to complex loads, such as acoustic pressure from the engine at launch and aerodynamic heating and aerodynamic pressure during flight. A thermal protection system panel is required to protect internal systems such as the fuel tank of the vehicle from the external environment. This study defines analytical models for heat transfer and thermal structure characteristics of the thermal protection system panel. Furthermore, the study performed parameters analysis to achieve the thermal structural integrity and to make it lighter.

  • PDF

Thermal shock characteristics of FGM for gas turbine blade (가스터빈 날개용 경사기능재료의 열충격 특성)

  • Lim, Jae-Kyoo;Song, Jun-Hee;Kim, You-Jig
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.73-79
    • /
    • 1998
  • The development of a new material which should be continuously usable under severe environment of very high temperature has been urgently requested. The conventional thermal barrier coating(TBC) is a two layer coating, but a composition and a microstructure of functionally graded material(FGM) are varied continuously from place to place in ways designed to provide it with the maximum function of mitigating the induced thermal stress. The purpose of this study is to evaluate the heat-resistant characteristics by thermal shock of laser and furnace heating. The fracture behaviors of non-FGM(NFGM) and FGM were investigated based on acoustic emission(AE) technique during thermal shock test. Therefore, it can be concluded that FGM gives higher thermal resistance compared to NFGM by AE signal and fracture surface analysis.

Comparisons of Thermal-moisture Properties in Combination of 3D spacer and Polyurethane(PU) Foam for Mold Brassiere Cups (몰드 브래지어 컵의 제작을 위한 3D 스페이서 패브릭과 폴리우레탄(PU) 폼 조합에 따른 열·수분 전달 특성 비교)

  • Lee, Hyun Young;Park, Huiju
    • Korean Journal of Human Ecology
    • /
    • v.24 no.2
    • /
    • pp.285-295
    • /
    • 2015
  • To identify optimized thermal properties of mold brassiere cup for improved thermal comfort during summer, we compared the thermal resistance and the water vapor permeability of Polyurethane (PU) foam, 3D spacer fabric and the two combined materials of the PU foam and the 3D spacer fabric. Four experimental mold brassieres were made of the materials for wearing test. Six women in their twenties evaluated the wearing sensation in the hot and humid environment. The changes in microclimate temperature and humidity while wearing test brassiere cups were measured. Results indicate that thermal resistance increased as more PU foam were combined, while the water vapor permeability was higher as the content of the 3D spacer fabric increased at thickness of 18mm and over. However, in the wear test, the PU foam brassiere was the most preferred in all ambient conditions due to its soft, flexible and smooth texture, despite its high thermal resistance and low water vapor permeability. This indicates that the textures of mold foams are more dominant properties than thermal properties for mold foams in determining the wear comfort of mold brassieres.

Thermal Comfort Range of Radiant Floor Heating System by Residential Style (생활특성에 따른 바닥복사난방 공간의 열쾌적 범위에 관한 연구)

  • Kim, Sang-Hun;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.1
    • /
    • pp.7-14
    • /
    • 2015
  • This study has been purposed to provide thermal comfort range in accordance with the residential style of radiant floor heating space, and to compare it with the thermal comfort range at predicted mean vote. The survey for the thermal sensation vote to the subjects and the measurement of environmental factors has been executed, and regression analysis has been performed. It is interpreted that the combination of the physical factor and the psychological factor results lower neutral point of the floor sitting style than that of the chair sitting style. There are some difference between the measured predicted mean vote and the thermal sensation vote via survey, which appears to be caused by distinctive heat transfer characteristic of floor radiant heating space, such as, high radiant temperature and contact thermal sensation of floor surface.

Preperation of Silicon Carbide Oxidation Protection Film on Carbon Thermal Insulator Using Polycarbosilane and Its Characterization (폴리카보실란을 이용하여 탄소단열재에 코팅한 실리콘카바이드 코팅막의 내산화 특성)

  • Ahn, Su-Bin;Lee, Yoonjoo;Bang, Jung-Won;Shin, Dong-Geun;Kwon, Woo-Teck
    • Korean Journal of Materials Research
    • /
    • v.27 no.9
    • /
    • pp.471-476
    • /
    • 2017
  • In order to improve the high temperature oxidation resistance and lifespan of mat type porous carbon insulation, SiC was coated on carbon insulation by solution coating using polycarbosilane solution, curing in an oxidizing atmosphere at $200^{\circ}C$, and pyrolysis at temperatures up to $1200^{\circ}C$. The SiOC phase formed during the pyrolysis process was converted into SiC crystals as the heat treatment temperature increased, and a SiC coating with a thickness of 10-15 nm was formed at $1600^{\circ}C$. The SiC coated specimen showed a weight reduction of 8.6 % when it was kept in an atmospheric environment of $700^{\circ}C$ for 1 hour. On the other hand, the thermal conductivity was 0.17 W/mK, and no difference between states before and after coating was observed at all.

Comparison of OC and EC Measurement Results Determined by Thermal-optical Analysis Protocols (열광학적 분석 프로토콜에 의한 유기탄소와 원소탄소 측정값 비교)

  • Kim, Hyosun;Jung, Jinsang;Lee, Jinhong;Lee, Sangil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.449-460
    • /
    • 2015
  • Carbonaceous aerosol is generally classified into OC (organic carbon) and EC (elemental carbon) by thermal optical analysis. Both NIOSH (National institute of occupational safety and health) with high temperature (HighT) and IMPROVE-A (Interagency monitoring of protected visual environments) with low temperature (LowT) protocols are widely used. In this study, both protocols were applied for ambient $PM_{2.5}$ samples (Daejeon, Korea) in order to underpin differences in OC and EC measurements. An excellent agreement between NIOSH and IMPROVE-A protocol was observed for TC (total carbon). However, significant differences between OC and EC appeared and the differences were larger for EC than OC. The main differences between two protocols are temperature profile and charring correction method. For the same charring correction method, HighT_OC was 10% higher than LowT_ OC, while HighT_EC was 15% and 33% lower than LowT_EC for TOT (thermal-optical transmittance) and TOR (thermal-optical reflectance), respectively. This difference may be caused by the temperature of OC4 in He step and possibly difference in POC (pryorilized OC) formation. For the same temperature profile, OC by TOT was about 26% higher than that by TOR. In contrast, EC by TOT was about 50% lower than that by TOR. POC was also dependent on both temperature profile and the charring correction method, showing much distinctive differences for the charring correction method (i.e., POC by TOT to POC by TOR ratio is about 2). This difference might be caused by different characteristics between transmittance and reflectance for monitoring POC formation within filters. Results from this study showed that OC and EC depends on applied analysis protocol as shown other studies. Because of the nature of the thermal optical analysis, it may not be possible to have an absolute standard analysis protocol that is applicable for any ambient $PM_{2.5}$. Nevertheless, in order to provide consistent measurement results for scientists and policy makers, future studies should focus on developing a harmonized standard analysis protocol that is suitable for a specific air domain and minimizes variations in OC and EC measurement results. In addition, future elaborate studies are required to find and understand the causes of the differences.

A Study on the Application of a Turbidity Reduction System for the Utilization of Thermal Wastewater in High Turbidity Zones (고탁도 해역의 온배수 활용을 위한 탁도저감시스템 적용에 대한 연구)

  • Ha, Shin-Young;Oh, Cheol;Gug, Seung-Gi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.7
    • /
    • pp.916-922
    • /
    • 2018
  • Recently, power plant effluent condensers received a Renewable Energy Certificate as components of hydrothermal energy (weighted 1.5 times) as one target item of the Renewable Portfolio Standard (RPS) policy. Accordingly, more attention is being paid to the value of thermal wastewater as a heat source. However, for utilization of thermal wastewater from power plants in high-turbidity areas like the West Sea of Korea, a turbidity reducing system is required to reduce system contamination. In this study, an experimental test was performed over a month on thermal wastewater from power plants located in the West Sea of Korea. It was found that water turbidity was reduced by more than 80 % and that the concentration of organic materials and nutrient salts was partially reduced due to the reduction of floating/drifting materials. To conduct a comparative analysis of the level of contamination of the heat exchanger when thermal wastewater flows in through a turbidity reducing system versus when the condenser effluent flows in directly without passing through the turbidity system, we disassembled and analyzed heat exchangers operated for 30 days. As a result, it was found that the heat exchanger without a turbidity reducing system had a higher level of contamination. Main contaminants (scale) that flowed in to the heat exchanger included minerals such as $SiO_2$, $Na(Si_3Al)O_8$, $CaCO_3$ and NaCl. It was estimated that marine sediment soil flowed in to the heat exchanger because of the high level of turbidity in the water-intake areas.