Abstract

This study has been purposed to provide thermal comfort range in accordance with the residential style of radiant floor heating space, and to compare it with the thermal comfort range at predicted mean vote. The survey for the thermal sensation vote to the subjects and the measurement of environmental factors has been executed, and regression analysis has been performed. It is interpreted that the combination of the physical factor and the psychological factor results lower neutral point of the floor sitting style than that of the chair sitting style. There are some difference between the measured predicted mean vote and the thermal sensation vote via survey, which appears to be caused by distinctive heat transfer characteristic of floor radiant heating space, such as, high radiant temperature and contact thermal sensation of floor surface.

Keywords

References

  1. Lee, Y. C. and Chung, K. S., 2002, An experimental study on the optimum zone of thermal comfort index in radiant floor heating system, Journal of AIK, Vol. 18, No. 3, pp. 137-143.
  2. Choi, Y. J., Shim, H. S., and Jeong, Y. H., 2007, An experimental study on difference of thermal sensation by radiant floor heating, Journal of KIEAE, Vol. 7, No. 5, pp. 65-71.
  3. Yoon, H. S. and Han, Y. H., 1991, A study on thermal comfort requirements of low temperature floor heating system(I), Journal of AIK, Vol. 7, No. 3, pp. 271-278.
  4. Lee, C. S. and Yoon. J. H., 2010, A study on the estimation of heating energy and $CO_2$ reduction depending on an indoor set temperature and clo value, Journal of the Korean Solar Energy Society, Vol. 30, No. 4, pp. 49-54.
  5. Kim, D. G. and Kim, S. H., 2012, The study of human response for floor surface temperature and resident's posture change, Korean Journal of Air Conditioning and Refrigeration Engineering, Vol. 24, No. 12, pp. 846-851. https://doi.org/10.6110/KJACR.2012.24.12.846
  6. Nam, D. H., Lee, Y. C., Baik, Y. K., and Chung, K. S., 2001, A study on the optimum thermal comfort range in radiant floor heating system, Proceeding of the AIK, Vol. 21, No. 1, pp. 557-560.
  7. Fanger, P. O., 1982, Thermal Comfort Analysis and Application in Environmental Engineering, McGraw-Hill Book Company.
  8. ISO, 1994, ISO 7730:1994 Moderate thermal environmental- Determination of the PMV and PPD Indices and Specification of the conditions for Thermal Comfort, International Organization for Standardization.
  9. ASHRAE, 2013, ANSI/ASHRAE Standard 55-2013 Thermal Environmental Conditions for Human Occupancy, American Society of Heating, Refrigerating, and Air-Conditioning Engineers.