• Title/Summary/Keyword: High Reliability Transmission

Search Result 354, Processing Time 0.029 seconds

QoS guaranteed IP multicast admission control mechanism (품질 보장형 IP 멀티캐스트 수락 제어 메커니즘)

  • Song, kang-ho;Rhee, wooo-Seop
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.51-55
    • /
    • 2008
  • Request High-Images, High-quality, duplex transmission, BcN Voice telephone, Broadcast, Data internet service came to be all possible and demolished original communication service area. Also, The quality is guaranteed stablely to new business and ISP the requirement comes to become a multicasting quality guarantee mechanism which there is the reliability for a information communication and High-quality multimedia service. Like this, a multicast mechanism to be guaranteed must become air control End-to-End QoS for a service supply, a transmission delay a packet loss or requirement which the user requests guarantee and multicast Path-NET which there is the reliability must be provided. Therefor, we proposed IP base multicast new join the present the multicast mechanism of Probing packet foundation which there is the efficiently a linking acceptance, we used ns-2 simulator for the performance evaluation of the proposed.

  • PDF

Optimization of Tree-like Core Overlay in Hybrid-structured Application-layer Multicast

  • Weng, Jianguang;Zou, Xuelan;Wang, Minhong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.12
    • /
    • pp.3117-3132
    • /
    • 2012
  • The tree topology in multicast systems has high transmission efficiency, low latency, but poor resilience to node failures. In our work, some nodes are selected as backbone nodes to construct a tree-like core overlay. Backbone nodes are reliable enough and have strong upload capacity as well, which is helpful to overcome the shortcomings of tree topology. The core overlay is organized into a spanning tree while the whole overlay is of mesh-like topology. This paper focuses on improving the performance of the application-layer multicast overlay by optimizing the core overlay which is periodically adjusted with the proposed optimization algorithm. Our approach is to construct the overlay tree based on the out-degree weighted reliability where the reliability of a node is weighted by its upload bandwidth (out-degree). There is no illegal solution during the evolution which ensures the evolution efficiency. Simulation results show that the proposed approach greatly enhances the reliability of the tree-like core overlay systems and achieves shorter delay simultaneously. Its reliability performance is better than the reliability-first algorithm and its delay is very close to that of the degree-first algorithm. The complexity of the proposed algorithm is acceptable for application. Therefore the proposed approach is efficient for the topology optimization of a real multicast overlay.

CSK/SS-DS Signal Transmission Characteristics in a Poor Channel Environment (열악한 채널 환경하에서의 CSK/SS-DS 신호의 전송 특성)

  • 오경석;이우재;신위재;강석규;주창복
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.243-247
    • /
    • 1999
  • For the purpose of LAN or data transmission line design with high speed and reliability using power lines, in this paper, we present CSK/SS-DS signal transmission characteristics simulations with changing channel characteristics due to impedance fluctuation. And we also simulated the signal transmissions with a strong impulsive burst noise and with a gaussian random noise. We introduce a simple channel equalization filtering method that solves the synchronization problem of CSK/SS-DS with fluctuating channel characteristics or low S/N ratio.

  • PDF

Application of Supervisory System in Extra High Voltage Cable (초고압 케이블의 송전 감시 시스템 소개 및 기술동향)

  • Kwon, Byung-Il;Nam, Jeong-Se;Kang, Deok-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1791-1793
    • /
    • 1997
  • Since Korea was initiated a industrialization, many transmission lines have been installed to meet the increasing demand for the electric power. In large city, underground transmission lines were widely installed because of the environmental issue. But there have been appeared many failures on the lines, such as the external scar of cable, a fire in the culvert, overheating of cable, and so on. There have been many studies to monitor them and improve the reliability of the power supply. As a method monitoring the lines, a DTS(Distributed Temperature Sensor) system is developed and applied. This system monitors the lines and predicts the failures, using a optical fiber sensor. This paper describes this DTS system and its application for the underground transmission lines.

  • PDF

In-Vehicle Network Technologies (차량 내 네트워크 기술)

  • Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.518-521
    • /
    • 2018
  • IVN (in-vehicle network) connects various electronic modules in the vehicles. It requires real-time, low noise, high reliability, and high flexibility. It includes CAN (controller area network), CAN-FD (CAN flexible data rate), FlexRay, LIN (local interconnect network), SENT (single edge nibble transmission), and PSI5 (peripheral sensor interface 5). In this paper, their operation priciples, target applications, and pros and cons are explained.

The development of fire protection trough (밀폐형 방재트러후 개발)

  • Hwang, S.C.;Kim, T.K.;Go, C.S.;Han, K.J.;Kim, D.B.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1168-1170
    • /
    • 1993
  • EHV underground transmission cable characterized by low loss and bulk capacity should have high reliability to be protected fully from external damages, not to speak of its quality. In 345kV underground transmission lines of our country, the usage of frie protection trough is standardized. Fire protection trough consists of combination of trough body, spacer, shutting board, fastener, and etc. and it is required to have a high level of fire-retardant characteristics and mechanical strength. Since 1992, we, GoldStar Cable, with collaboration of Lucky, have participated in the development of fire protect ion trough and completed the type test of manufacturing site and will be supposed to go into mass product within 1993.

  • PDF

Comparative Study for the Unloaded Quality Factors of High-Tc Superconductor-Dielectric Resonators Measured by Using S-parameter Circle-fit Method and Lorentzian-fit Method (S-parameter circle fit 방법과 Lorentzian fit 방법으로 측정된 고온초전도 유전체 공진기의 Unloaded Quality Factor 비교)

  • Kim, M.J.;Lee, J.H.;Park, E.K.;Yang, W.I.;Jung, H.S.;Choi, Y.O.;Lee, S.Y.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.143-151
    • /
    • 2007
  • Accurate measurements of the microwave surface resistance (Rs) of high temperature superconductor (HTS) films are important with regard to applications of HTS materials for wireless communications. As the surface resistance values of HTS films are usually extracted from the measured unloaded quality factor ($Q_0$) of resonators made of HTS films, it is essential to measure the resonator $Q_0$ with accuracy. The $TE_{011}\;mode\;Q_0$ of sapphire resonators with the endplates made of $YBa_2Cu_3O_{7-{\delta}}$(YBCO) film on $LaAlO_3$ is measured by using the S-parameter circle-fit method at a frequency of about 19.6 GHz and temperatures of 30 K to 90 K, which is compared with the measured values by using the Lorentzian-fit method. Good agreements are found between the two sets of $Q_0$ values measured by using the two different methods whether the resonator is used in a weak-coupling scheme or a strong-coupling scheme, showing reliability of both methods fur measuring the resonator $Q_0$ accurately. The $Q_0$ of sapphire resonators with a gap between the top plate and the rest of the resonator is also discussed.

  • PDF

A Study on the Digital Relaying Techniques by Real-Time Symmetrical Components of Power System (전력계통의 실시간 대칭성분을 이용한 거리계전 기법에 관한 연구)

  • 신명철;김철환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.10
    • /
    • pp.695-702
    • /
    • 1987
  • Nowadays as the power systems have been more complicated and have grown to ultra high voltage, it requires a accurate and high speed relaying scheme to improve the reliability and stability of power systems for a harmonious power supplying. For this purpose voltage and current have to be measured at the location of the protective device and the short circuit impedance must be determined. This paper presents the application methods and some results of digital distance relaying scheme which is based upon the theouy of real-time symmetrical components. Usually the symmetrical component have been used to solve the transient systems as well as the steady state systems under unbalanced systems. But, real-time symmetrical component frequently have not been applied to on-line control region of the large power system. We have tried to apply this method to deal with the various type of faults on artificial transmission line. And experimental results demonstrate the validity of the proposed techniques. Therefore, this study is expected that it is contributed to improve the reliability of power supplying, searching for the fault location rapidly and exactly in power system.

  • PDF

Real-time 3D Graphic Simulation of the Spent Fuel Rod Extracting Machine for Remote Monitoring (사용후핵연료봉 인출장치의 원격감시를 위한 실시간 3차원 그래픽 시뮬레이션)

  • 송태길;이종열;김성현;윤지섭
    • Korean Journal of Computational Design and Engineering
    • /
    • v.5 no.4
    • /
    • pp.327-335
    • /
    • 2000
  • The spent fuel rod extracting machine is automatically operated in high radioactive environment, so high reliability of operation is required. In this paper, to enhance the reliability of this machine by providing a close monitoring capability. a real time graphic simulation method is suggested. This method utilizes conventional IGRIP (Interactive Graphics Robot Instruction Program) 3D graphic simulation tool to visualize and simulate the 3D graphic model of this machine. Also, the dedicated protocol is defined for transmission of the operational data of the machine. The real time graphic simulation is realized by developing the socket module between a graphic workstation and a machine control computer through the TCP/IP network and by dividing the 3D graphic simulation GSL(Graphic Simulation Language) program as a small sized sub routine. The suggested method is implemented while automatically operating the rod extracting machine. The result of implementation shows that the real time 3D graphic simulation is well synchronized with the actual machine according to the operational data.

  • PDF

Fault detection using heartbeat signal in the real-time distributed systems (실시간 분산 시스템에서 heartbeat 시그널을 이용한 장애 검출)

  • Moon, Wonsik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.3
    • /
    • pp.39-44
    • /
    • 2018
  • Communication in real-time distributed system should have high reliability. To develop group communication Protocol with high reliability, potential fault should be known and when fault occurs, it should be detected and a necessary action should be taken. Existing detection method by Ack and Time-out is not proper for real time system due to load to Ack which is not received. Therefore, group communication messages from real-time distributed processing systems should be communicated to all receiving processors or ignored by the message itself. This paper can make be sure of transmission of reliable message and deadline by suggesting and experimenting fault detection technique applicable in the real time distributed system based on ring, and analyzing its results. The experiment showed that the shorter the cycle of the heartbeat signal, the shorter the time to propagate the fault detection, which is the time for other nodes to detect the failure of the node.