• Title/Summary/Keyword: High Flow Rate

Search Result 3,258, Processing Time 0.041 seconds

Chemistry of mist deposition of organic polymer PEDOT:PSS on crystalline Si

  • Shirai, Hajime;Ohki, Tatsuya;Liu, Qiming;Ichikawa, Koki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.388-388
    • /
    • 2016
  • Chemical mist deposition (CMD) of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) was investigated with cavitation frequency f, solvent, flow rate of nitrogen, substrate temperature $T_s$, and substrate dc bias $V_s$ as variables for efficient PEDOT:PSS/crystalline (c-)Si heterojunction solar cells (Fig. 1). The high-speed camera and differential mobility analysis characterizations revealed that average size and flux of PEDOT:PSS mist depend on f, solvent, and $V_s$. The size distribution of mist particles including EG/DI water cosolvent is also shown at three different $V_s$ of 0, 1.5, and 5 kV for a f of 3 MHz (Fig. 2). The size distribution of EG/DI water mist without PEDOT:PSS is also shown at the bottom. A peak maximum shifted from 300-350 to 20-30 nm with a narrow band width of ~150 nm for PEDOT:PSS solution, whose maximum number density increased significantly up to 8000/cc with increasing $V_s$. On the other hand, for EG/water cosolvent mist alone, the peak maximum was observed at a 72.3 nm with a number density of ~700/cc and a band width of ~160 nm and it decreased markedly with increasing $V_s$. These findings were not observed for PEDOT:PSS/EG/DI water mist. In addition, the Mie scattering image of PEDOT:PSS mist under white bias light was not observed at $V_s$ above 5 kV, because the average size of mist became smaller. These results imply that most of solvent is solvated in PEDOT:PSS molecule and/or solvent is vaporized. Thus, higher f and $V_s$ generate preferentially fine mist particle with a narrower band width. Film deposition occurred when $V_s$ was impressed on positive to a c-Si substrate at a Ts of $30-40^{\circ}C$, whereas no deposition of films occurred on negative, implying that negatively charged mist mainly provide the film deposition. The uniform deposition of PEDOT:PSS films occurred on textured c-Si(100) substrate by adjusting $T_s$ and $V_s$. The adhesion of CMD PEDOT:PSS to c-Si enhanced by $V_s$ conspicuously compared to that of spin-coated film. The CMD PEDOT:PSS/c-Si solar cell devices on textured c-Si(100) exhibited a ${\eta}$ of 11.0% with the better uniformity of the solar cell parameters. Furthermore, ${\eta}$ increased to 12.5% with a $J_{sc}$ of $35.6mA/cm^2$, a $V_{oc}$ of 0.53 V, and a FF of 0.67 with an antireflection (AR) coating layer of 20-nm-thick CMD molybdenum oxide $MoO_x$ (n= 2.1) using negatively charged mist of 0.1 wt% 12 Molybdo (VI) phosphoric acid n-Hydrate) $H_3(PMo_{12}O_40){\cdot}nH_2O$ in methanol. CMD. These findings suggest that the CMD with negatively charged mist has a great potential for the uniform deposition of organic and inorganic on textured c-Si substrate by adjusting $T_s$ and $V_s$.

  • PDF

Efficacy and Cost Benefits of Rapid Antigen Detection Test for Group A Streptococci Obtained from Acute Pharyngitis in Children (소아 세균성 인두 편도염의 진단에 있어 신속 항원 검출 검사의 유용성과 비용 효과의 평가)

  • Youn, Suk;Chung, Hye-Jeon;Kim, Yun-Ho;Choi, Jin-Dong;Lee, Sang-Hoon;Min, Jung-Sik;Jung, Sang-Young;Jung, Sung-Ki;Ahn, Byung-Moon;Lee, Hee-Joo;Cha, Sung-Ho
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.124-134
    • /
    • 2005
  • Purpose : It has been known that the diagnostic confirmation of group A streptococcal pharyngitis is accompanied with the results of throat culture and/or rapid antigen detection test(RADT). This study was designed to evaluate the usefulness and cost benefits of the RADT in patients with a sore throat compared the empirical antibiotic treated group without using RADT or throat culture with the antibiotic treated group according to the results of RADT test and/or throat culture. Methods : From April 2003 to August 2003, total 369 patients were enrolled this study. They were redistributed into two groups. In one group, the RADT test and throat culture were used and the patients received antibiotic treatment according to the results of test and in the other group, no diagnostic examinations were used and the patients were treated with antibiotics which were chosen empirically. The flow sheet with questionnaire was drawing up and obtained the clinical symptoms, signs and the name of antibiotics that were administered. Results : A total of 244 patients were treated after the throat culture and/or RADT, and 125 patients were treated empirically. The prevalence of bacteriologically confirmed group A streptococcal pharyngitis was 20.1%. The sensitivity and specificity of RADT were 89.8% and 86.1%, respectively. Positive predictive value and negative predictive value were 62.0% and 97.1%, respectively. The rate of antibiotic use was high in both groups. Because the physician used the antibiotics even if the result of RADT was negative. So about 37% of reduction of antibiotics use might be possible if we used antibiotics according to the results of RADT. There were no cost differences between the RADT applied group and the empirically treated antibiotic group if we could reduce the price of RADT to 63% of the current price. Conclusion : The RADT could be applied for the easy and rapid diagnosis and prompt treatment for group A streptococcal pharyngitis, and RADT could reduced the number of antibiotics used if the price of RADT was reduced to 63% of current price. For accurate evaluation of efficacy and cost effect, further controlled study is needed.

  • PDF

Determinants of the Location and Relocation of Domestic Logistics Firms in Korea (focused on complementary commodity flow survey for 2006) (우리나라 국내 화주기업의 입지 및 재입지 선택 특성 분석 (2006년 물류현황보완조사를 중심으로))

  • Do, Hwa-Yong;Jang, Hoon;Kim, Chan-Sung;Won, Jai-Mu
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.1
    • /
    • pp.37-49
    • /
    • 2008
  • In general, most of the firms do not settle down in one place for their pursuit of profit. There are many reasons for the relocation of the firms; procurement of raw material, market area, transportation cost and housing cost. The aspect of national policy, firm relocation has been systemically promoted for the purpose of logistics system efficiency. Nowadays balanced regional development has been issue. Another aspect, many countries have struggled for the preoccupancy of new place because of its production cost saving and curtailment of expenditure. The aim of this article is qualitative and quantitative analysis of relocation influence factors of domestic goods firms in Korea. This article dynamically analyzed the relocation influence factors for domestic goods firms in Korea. For the analysis this article made use of complementary survey (2006) out of the 3rd national logistics survey (2005). The complementary survey conducted pre-business district, business period, relocation reason, etc. This article dynamically analyzed from the three aspects; observation of average residence time in one business district, relocation factors, influence of market area. Analysis shows that relocation of firm is very high rate and the reasons of relocation play compositeness role. The results of determinants of location, firms approach the established market area closely and the firm's relocation is influenced by market area.

Impacts of Contaminated Water Outflow from the Lake Sihwa on the Meiobenthic Animals Living in the Coastal Zones of the Kyonggi Bay (시화호 오염수 방류에 따른 중형저서동물의 군집변동)

  • 김동성;이재학
    • Korean Journal of Environmental Biology
    • /
    • v.18 no.2
    • /
    • pp.279-290
    • /
    • 2000
  • To alleviate the harmful effects from contamination, the Sihwa Lake waters have been regularly fluxed out into the ocean to mix and circulate with the oceanic waters, and then allowed to flow back into the lake. In the present study, eco-environmental impacts by the outflowing contaminated lake waters to the benthic communities of the coastal zones along Kyonggi Bay were examined at three separate areas. A total of 22 groups of meiobenthic animals were commonly found in the subtidal zones of the Bay. All groups of the meiobenthic animals on the 1st and 7th days after the outflow were remarkably reduced in numbers from the selected areas examined, as compared to those observed one day before the outflow. It was also found that the community structure of meiobenthos was changed drastically: At the station near the water gate, for example, where the immediate outflow of the lake water was encountered, the benthic harpacticoids, the group observed to be one of the predominant groups before the outflow, were found to have disappeared completely. For an area that was relatively far away from the water gate, the reduction rate of meiobenthos after the outflow events was slower and more gradual than the nearer sites. An area that is the farthest from the water gate, no reduction in any of the meiobenthos group was observed. The ratio between nematodes/copepods (N/C) was remarkably changed by the outflows at the station near the water gate: One day before the outflow, the ratio was 0.7 while the ratio was 19.0 at the station near the water gate. In contrast, at the stations relatively far from the water gate, the ratio decreased one day after the outflow event, but increasing trends were observed one week later. In the tidal flats, Station 1 exhibited the common observed regional values of the ratio whereas Station 2 showed a very high ratio of 191.3. The results suggested that the contaminated lake water outflows directly effect meiobenthos in a relatively short time period and thus the meiobenthos may be a good indicator animal group for examining the effect of pollution. [Lake Sihwa, contaminat water outflow, meiobenthic animals living]

  • PDF

The Study for Results of Complex Cystic Breast Masses by Biopsy on Ultrasound (초음파상 복합성 낭성 유방 종괴의 조직 검사 결과에 관한 연구)

  • Kang, Hye-Kyoung;Dong, Kyung-Rae
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.129-134
    • /
    • 2008
  • Purpose: We examined the roles of Ultrasonography conductors by analyzing the results of tissue biopsy of complex cystic masse under the guidance of breast US. Objects and methods: This study was performed to a group of 178 who showed breast US indicating complex cystic masses among 342 patients who were definitely diagnosed by tissue biopsies and operations in our hospital from June 30th, 2003 to June 30th, 2007. The evaluation of tissues around, calcification, the distribution state of blood flow were excluded from the analysis subjects and logic 200 made by GE corporation and gun for core biopsy(Kimal corp., K7/MBD23) were used in this study. Results: The biopsy results of 178 subjects showed FCC (fibrocystic change)(n=56 : 31.4%), Fibrosis (n=41 : 23.0%), Fibroadenoma (n=20 : 11.2%), Epithelial hyperplasia (n=17 : 9.6%), Carcinoma (n=15 : 8.4%), Fibroadipose (n=8 : 4.5%), Sclerosing adenosis (n=7 : 3.9%), Duct ectasia (n=5 : 2.8%), Papiloma (n=5 : 2.8%), and Fat necrosis (n=1 : 0.6%), Hemangioma (n=1 : 0.6%), Abscess (n=1 : 0.6%), Dystrophic calcification(n=1 : 0.6%). Conclusion: The US showed that the results of the tissue biopsy of complex cystic masses were mostly carcinoma(8.4%). Most of them were benign and only 9.6% of epithelial hyperplasia which has high progression rate into malignant tumors epidemically showed malignancy. Most of them were included in the spectrum of fibrous cystic nodule. Even though these results are confirmed, further studies are required. As a result, a nodule which is not certified by US should be right to take the tissue biopsy, but if it's difficult due to patients or another reasons, re-check tests in three months are required. And systemic ultrasonography evaluation should be well recognized to conduct more careful and specific tests.

  • PDF

The Surgical Management of Hypoplastic Left Heart Syndrome and the Results of a Fontan Operation (좌심형성부전증후군의 외과적 치료 및 폰탄수술의 결과)

  • Chung, Eui Suk;Kim, Woong-Han;Jeon, Jae-Hyun;Choi, Chang-Hyu;Lee, Chang-Ha;Lee, Young-Tak
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.9-13
    • /
    • 2009
  • Background: Hypoplastic left heart syndrome is uniformly fatal if this condition is not properly treated. We reviewed the surgical results of treating hypoplastic left heart syndrome, and we evaluated the hemodynamics and functional status of these patients after they underwent a Fontan operation. Material and Method: To assess the surgical results, we retrospectively reviewed the medical records of 6 (M/F=4/2) patients who underwent a staged operation, including a Norwood procedure, a bidirectional Glenn procedure and a Fontan procedure between October 1997 to May 2005. The mean age of the patients was $17.3{\pm}10.8$ days (range: 9~36 days) at the $1^{st}$ staged operation, $8.9{\pm}7.1$ months (4.6~23.3 months) at the $2^{nd}$ staged operation (the Bidirectional Glenn procedure) and $32.4{\pm}9.8$ months at the final staged operation (the Fontan procedure). During the $2^{nd}$ staged operation, one of the patients received tricuspid valve repair due to regurgitation. All the patients underwent an extracardiac Fontan procedure using Gore-Tex conduit (20 mm: 2 patients, 18 mm: 4 patients) and one of them required fenestration. Result: 21 patients underwented a Norwood procedure. There were 7 early deaths and 4 interstage deaths. Bidirectional cavopulmonary shunt was performed in 10 patients and the Fontan procedure was done in 6 (mortality: 1 patient, Flow up loss: 1 patient, Awaiting a Fontan procedure: 2 patients). After the Fontan procedure, there was no complication except for one case of post operative bleedings. All the patients had good ventricular function and 2 had grade I tricuspid regurgitation, as noted on their echocardiography. The average follow up period after the Fontan procedure was $19.6{\pm}14.9$ months (range: 1.5~39.1 month). All the patients had normal sinus rhythm and they were put on aspirin and cardiac medication. During follow up period, all the patients had a good functional status (NYHA functional class I). Conclusion: All the patients who suffered with hypoplastic left heart syndrome and who underwent a Fontan procedure achieved a good hemodynamic and functional status, even though there was a relatively high operative mortality rate after stage I Norwood palliation. Therefore, thise staged operation should be strongly recommended as an important surgical strategy for treating hypoplastic left heart syndrome.

Volatilization of Sprayed Pesticides in Greenhouse using a Lysimeter (라이시미터를 이용한 시설하우스 내에 살포한 농약의 휘산 양상)

  • Kim, Danbi;Kim, Taek-Kyum;Kwon, HyeYong;Hong, Su-Myeong;Park, Byung-Jun;Lim, Sung-Jin;Lee, Hyo-Sub;Moon, Byeong-Cheol
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.4
    • /
    • pp.305-311
    • /
    • 2016
  • In cultivation environment, various pesticides are used and some of them could be volatilized into the air. This could affect farmer's health and also cause environmental pollution. This study was carried out to investigate the volatilization of pesticides, and use the reference data for preventing farmer's pesticide intoxication and securing worker safety. The experiment was conducted in a greenhouse using a lysimeter which was of $1m^2$ area and 1.5 m depth filled with upland soil. The pesticides treated in lysimeter soil were ethoprophos (5.0% GR), diazinon (34.0% EC), alachlor (43.7% EC), metolachlor (40.0% EC), chlorpyrifos (2.0% GR), pendimethalin (31.7% EC), carbaryl (50.0% WP), napropamide (50% WP), tebuconazole (25.0% WP) and imidacloprid (2.0% GR). Each pesticide was treated at a concentration of 770.5 mg based on A.I (%). The recovery of pesticide ranged from 77.4 to 99.3%. The volatilized pesticides in air were collected by personal air sampler with PUF tube at 4 l/min flow rate. In addition, temperature and humidity were measured. The collected samples were extracted using acetone in a soxhlet apparatus for 8 hours. The extracted pesticides were resoluted with acetonitrile and diluted 5 times. It was analyzed with LC-MS/MS. For 720 hours experiment, the largest vaporization amount of each pesticide in air was ethoprophos $15.24{\mu}g/m^3$, diazinon $5.14{\mu}g/m^3$, pendimethalin $2.70{\mu}g/m^3$, chlorpyrifos $1.76{\mu}g/m^3$, alachlor $1.40{\mu}g/m^3$, metolachlor $1.12{\mu}g/m^3$, carbaryl $0.27{\mu}g/m^3$, napropamide $0.22{\mu}g/m^3$, tebuconazole $0.11{\mu}g/m^3$ and imidacloprid $0.05{\mu}g/m^3$. The R value (coefficient of correlation) between volatilization and vapor pressure of pesticides is higher than 0.99. Therefore, there is high correlation between volatilization and vapor pressure of pesticides.

Varietal Analysis and Quantification of Resveratrol in Mulberry Fruits (뽕나무 계통별 오디의 레스베라트롤 함량 분석)

  • Kim Hyun-Bok;Kim Jung-Bong;Kim Sun-Lim
    • Journal of Sericultural and Entomological Science
    • /
    • v.47 no.2
    • /
    • pp.51-55
    • /
    • 2005
  • Resveratrol is naturally occurring phytoalexin compounds produced by grape berries, peanuts, and their products in response to stress such as fungal infection, heavy metal ions or UV irradiation. The objective of this study was to develope a reliable high performance liquid chromatographic (HPLC) method for the quantitative determination of trans-resveratrol in mulberry fruit. Samples were extracted in 80% MeOH and filtered with $0.45{\mu}m$ syringe filter. The transresveratrol was separated Waters $C_{18}$ column, using a mobile phase containing 0.025% trifluroacetic acid in 5% acetonitril and 0.035% trifluroacetic acid in 50% acetonitril, detected by photodiode array detector (PDA) at 254 nm and the flow rate was 1ml/min. Under this analytical condition, the mean content of mulberry fruits (fifty varieties) was $777.3{\pm}585.9ppm$. Among the tested samples, 'Mansaengbaekpinosang (II)' was the highest level in 3450.6 ppm. However four accessions including 'Gukbu', 'Sabangso (I)', 'Simseol' and yield mulberry fruit were not able to detected. Eight suitable varieties selected for the production of fruit were 'Jeolgokchosaeng (Chungbuk)' 777.8 ppm, 'Dangsang 7' 771.1 ppm, 'Jangsosang' 133.9 ppm, 'Susungppong' 31.1 ppm, 'Suwonnosang' 639.7 ppm, 'Palcheongsipyung' 1475.9 ppm, 'Kangsun' 864.0 ppm, and 'Jukcheonchosaeng' 1458.5 ppm. 'Daesungppong' which was the first authorized variety for the production of mulberry fruit was 1236.7 ppm. In conclusion, these results suggest that mulberry including fruit and leaf may a good new resource for resveratrol production.

Comparison of Respiratory Mechanics and Gas Exchange Between Pressure-controlled and Volume-controlled Ventilation (압력조절환기법과 용적조절환기법의 호흡역학 몇 가스교환의 비교)

  • Jeong, Seong-Han;Choi, Won-Jun;Lee, Jung-A;Kim, Jin-A;Lee, Mun-Woo;Shin, Hyoung-Shik;Kim, Mi-Kyeong;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.662-673
    • /
    • 1999
  • Background : Pressure-controlled ventilation (PCV) is frequently used recently as the initial mode of mechanical ventilation in the patients with respiratory failure. Theoretically, because of its high initial inspiratory flow, pressure-controlled ventilation has lower peak inspiratory pressure and improved gas exchange than volume-controlled ventilation (VCV). But the data from previous studies showed controversial results about the gas exchange. Moreover, the comparison study between PCV and VCV with various inspiration : expiration time ratios (I : E ratios) is rare. So this study was performed to compare the respiratory mechanics and gas exchange between PCV and VCV with various I : E raitos. Methods : Nine patients receiving mechanical ventilation for respiratory failure were enrolled. They were ventilated by both PCV and VCV with various I : E ratios (1 : 2, 1 : 1.3 and 1.7 : 1). $FiO_2$, tidal volume, respiratory rate and external positive end-expiratory pressure (PEEP) were kept constant throughout the study. After 20 minutes of each ventilation mode, arterial blood gas, airway pressures, expired $CO_2$ were measured. Results : In both PCV and VCV, as the I : E ratio increased, the mean airway pressure was increased, and $PaCO_2$ and physiologic dead space fraction were decreased. But P(A-a)$O_2$ was not changed. In all three different I : E ratios, peak inspiratory pressure was lower during PCV, and mean airway pressure was higher during PCV. But $PaCO_2$ level, physiologic dead space fraction and P(A-a)$O_2$ were not different between PCV and VCV with three different I : E ratios. Conclusion : There was no difference in gas exchange between PCV and VCV under the same tidal volume, frequency and I : E ratio.

  • PDF

Investigation into Air Pollution in Car Shipping Workshop in Pyeongtaek Port (자동차 선적작업장의 공기오염 실태조사)

  • Kim, Ji-Ho;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.44-53
    • /
    • 2006
  • This study purposed to investigate air pollution in car shipping yards and, for this purpose, we selected an outdoor open-air yard and an indoor ramp into the ship and measured the concentrations of sulfur dioxide, nitrogen dioxide, carbon monoxide, PM10, PM2.5 and heavy metals in the air. The results of this study are as follows. No significant difference was observed in temperature and humidity between the outdoor and indoor workshop, and the average air flow was 0.52 m/s in the indoor workshop, which is higher than 0.19 m/s in the outdoor workshop(p<0.01). The average concentrations of sulfur dioxide, nitrogen dioxide, carbon monoxide, PM10 and PM2.5 according to workplace were 0.03 ppm(${\pm}0.01$), 0.03 ppm(${\pm}0.01$), 0.46 ppm(${\pm}0.22$), $39.44{\mu}g/m^3$(${\pm}2.45$) and $5.45{\mu}g/m^3$(${\pm}1.15$) respectively in the outdoor workshop, and 0.15 ppm(${\pm}0.05$), 0.22 ppm(${\pm}0.06$), 8.85 ppm(${\pm}3.35$), $236.39{\mu}g/m^3$(${\pm}58.21$) and $152.43{\mu}g/m^3$(${\pm}35.42$) respectively in the indoor workshop. Thus, the concentrations of gaseous substances in the indoor workshop were 4.9-19.2 times higher than those in the outdoor workshop, and the concentrations of fine dusts were 5.9-27.9 times higher(p<0.01). In addition, according to the result of investigating pollutant concentrations according to displacement and the number of car loaded when shipping gasoline cars into the ship, no significant relation between the number of cars loaded and pollutants was observed in shipping passenger cars, but the concentrations of nitrogen dioxide and carbon monoxide got somewhat higher with the increase of the number of cars loaded(p<0.05). In addition, the concentrations of nitrogen dioxide, carbon monoxide, PM10 and PM2.5 in the air were significantly higher when shipping recreational vehicles, the displacement of which is larger than passenger cars, than when shipping passenger cars(p<0.01). On the other hand, the average heavy metal concentrations of the air in indoor workshop were: lead $-0.05{\mu}g/m^3$(${\pm}0.10$); chromium $-0.90{\mu}g/m^3$(${\pm}0.18$); zinc $-0.38{\mu}g/m^3$(${\pm}0.24$); copper $-0.18{\mu}g/m^3$(${\pm}0.22$); and manganese and cadmium not detected. In addition, the complaining rates of 'asthma,' a major symptom of chronic respiratory diseases, were 18.5% and 22.5% respectively in indoor workers and outdoor workers. Thus the rate was somewhat higher in indoor workers but the difference was not statistically significant. The complaining rates of 'chronic cough' and 'chronic phlegm' were very low and little different between indoor and outdoor workers. The results of this study show that the reason for the higher air pollution in indoor than in outdoor workshop is incomplete combustion of fuel due to sudden start and over-speed when cars are driven inside the ship. In order to prevent high air pollution, efficient management measures should be taken including the observance of the optimal speed, the improvement of old ships and the installation of efficient ventilation system.