• Title/Summary/Keyword: Height variation

Search Result 1,130, Processing Time 0.03 seconds

Intraannual and Vertical Variations in Rays of Pinus koraiensis and Larix kaempferi Woods Grown in Korea (잣나무와 낙엽송재 방사조직의 연륜 내 및 축방향 변이성)

  • Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.65-72
    • /
    • 2009
  • Variation of wood rays within a growth ring and along axial direction in Pinus koraiensis and Larix kaempferi, which are important Korean commercial softwoods, was examined to get some useful information for their effective utilization. Ray height in cell number and ray number per $0.25mm^2$ in tangential section were investigated by optical microscopy. The average heights of uniseriate rays in Pinus koraiensis and Larix kaempferi were 6.3 and 9.1 cells, respectively. The average numbers of uniseriate rays per $0.25mm^2$ in Pinus koraiensis and Larix kaempferi were 6.5 and 7.5, respectively. The average heights of fusiform rays were about 20 cells but were not significantly different in both species. From earlywood to latewood within a growth ring, the heights of uniseriate and fusiform rays decreased but their numbers remained almost constant. Along axial direction, the heights of uniseriate rays in both species increased with the increase of stem height, and the numbers of uniseriate rays per $0.25mm^2$ in Pinus koraiensis were nearly constant from 0.2 m to 5.2 m but increased up to 19.2 m beyond 5.2 m. However, a constant pattern in the numbers of uniseriate rays was not observed in Larix kaempferi. The heights of fusiform rays in both species were the highest in middle part of stems but were the lowest in base and top of trees. In conclusion, the ray variation pattern was comparatively clear within a growth ring but not clear along axial direction.

Program Development for Design of Counter-flow Cooling Tower (향류형 냉각탑의 기본설계 프로그램 개발)

  • Ko, Kwang-Ho;In, Jong-Soo;Oh, Tae-Il
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.4
    • /
    • pp.383-389
    • /
    • 2004
  • This paper is to develop the program for sizing of a counter-flow cooling tower. Air flow, air exit tmperature, fan power are calculated from design coditions of cooling tower by using this program. The basic equations and solutions of the heat transfer and pressure drop of cooling tower are descrived and the algorithm development for design of cooling tower is performed. The variation of fan power of cooling tower in acoording to variation of cell area and fill height is performed by using this program. This result shows that the optimal design for install and running cost of cooling tower can be performed by using this program.

  • PDF

Experimental Study on The Propagation Characteristics of Lightning Surge According to Variation of Wire Length (배선 길이 변화에 따른 뇌서지 전파 특성에 대한 실험 연구)

  • Seo Ho-Joon;Rhie Dong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.12
    • /
    • pp.616-619
    • /
    • 2004
  • Electrical circuits with semiconductor are very weak against lightning surge. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. To achieve effective method of surge protection, there are needs for correlation between lightning surge and indoor wire length or installation height of indoor wire. The aim of this present work is to investigate the propagation characteristics of lightning surge according to variation of wire length. As a consequence, the maximum voltage at the end of the open wire in proportion to length of indoor wire. Therefore this result may be raw data for establishment of surge protection system.

Magnetic Circuit and Characteristics of A flux Concentrated Spoke Type. Permanent Magnet BLDC Motor (자속 집중형 Spoke Type 영구자석 BLDC 전동기의 자기회로 및 특성 해석)

  • Kang, Gyu-Hong;Lee, Byoung-Kuk;Hur, Jin
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.3
    • /
    • pp.135-142
    • /
    • 2004
  • In this paper, the magnetic circuit characteristics and the current/torque analysis of a Spoke Type permanent magnet motor have been researched, compared with the SPM Type motor. In the magnetic circuit analysis, the characteristic of air-gap flux density has been analyzed according to the variation of the number of pole and the ratio of magnet height to arc length using finite element method and circuit equations. Moreover, the electromagnetic and the reluctance torque have been analyzed by the current profile, which is obtained from the variation of turn-on angle, and these informative data has been utilized for the overall characteristics of the Spoke Type BLDC motor.

Numercal Simulation of Unsteady Performance for 20D Surface Effect Airfoils (2차원 해면효과익의 비정상 성능에 대한 수치적 시뮬레이션)

  • Park, Il-Ryong;Jeon, Ho-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.71-74
    • /
    • 1995
  • A numerical model capable of simulating a 2-D airfoil flying over in the vicinity of the waves is discussed. Instead of treating the problem as a heaving oscillation one above the rigid flat wall, sources are distributed on the prescribed wave profile. The wave deformation due to the airfoil is assumed to be negligible and treated as a rigid undulated wall. The source and vortex are distributed on the surface of the foil. It is found that the variation of $C_L$ with wave steepness in severe and that the lift variation due to waves decreases as the wing height above the water surface increases.

  • PDF

The temperature and humidity variation along the width of greenhouse with Pad & Fan system (PAD & FAN 시스템에 대한 온실폭방향의 온. 습도 변화)

  • 이종원;이석건;이현우;김란숙;최상환
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.262-268
    • /
    • 1998
  • This study were performed to find the cooling effect and to provide design data during summer season. for the Pad & Fan system of Venlo type greenhouse. The temperature and humidity variation along the greenhouse width and wind velocity in the greenhouse were surveyed. Also, the influence of shading on the cooling effect were analyzed. While Pad & Fan system were operated, the temperature, humidity and wind velocity in greenhouse were different by the distance from the Pad and the height from the ground. The temperature difference between Pad and Fan was about 8.1$^{\circ}C$~10.4$^{\circ}C$ without shading and about 4.4$^{\circ}C$~5.5$^{\circ}C$ with shading.

  • PDF

Wave Transformation in the Intersecting Wave Trains (2방향 파랑하에서 파의 변형)

  • 김경호;조재희;윤영호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.4
    • /
    • pp.313-320
    • /
    • 1995
  • A numerical analysis on the wave deformation in the shallow water region is performed for the case of two intersecting wave trains of the same frequency on uniformly sloping beaches. This model is based on the consideration of wave energy balance and wave action conservation, and iteratively solved the set of conservation equations of both mass and horizontal momentum. Using the computed results, the wave deformations in accordance with the variation of the parameters luck as incident wave angie and wave height in deep water which influences the variation of wave hight and mean water level under the intersecting wave trains in the shallow water region. are considered.

  • PDF

Variation of Camera Constant and Image Rotation in HU-125C Electron Microscope (HU-125C 전자현미경에 있어서 카메라 상수의 변화 및 상의 회전에 대한 조사)

  • Choi, Ju;Ye, Gil-Chon
    • Applied Microscopy
    • /
    • v.4 no.1
    • /
    • pp.1-4
    • /
    • 1974
  • Variations of camera constant due to the change of the lens current were examined for Hitachi HU-125C electron microscope. It was shown that the variation in specimen height had a marked effect on the change of camera constant. Also the rotation of the image from the diffraction pattern was determined by using a test crystal. Suggestions were given for improving practical operation of electron microscope in the work of thin foils.

  • PDF

Distribution Characteristics of a Mini -Sprinkler without a Bridge (Non-bridge 형 미니스프링쿨러의 살수 특성)

  • 이남호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.1
    • /
    • pp.66-72
    • /
    • 2000
  • A study was conducted to find distribution patterns of minisprinkler without a bridge for the desing of microirrigation systems. The experiments were executed in a plastic house to minimize the effect of the wind. Data were collected at four different operation pressures and at 3 different riser heights. Sprayed water were collected by aluminium cans with 65mm diameter and 100mm height placed at 0.3m grid spacing . A schematic distribution pattern with distance from a minisprinkler was suggested for the layout design of the minisprinkler. Distribution pattern of the minisprinkler was found irregular in space. Distributin performance characteristics of the minisprinkler such as effective radius. , effective area, mean application depth, absolute maximum application depth, effective maximum application depth and coefficient of variation were determined. It was indicated that there is a trend of decrease in variation coefficient adn better water distribution by the increase in operation pressures and riser heights.

  • PDF

The study of combustion characteristics and emissions with the variation of design factor on slit gas burner (슬릿버너에서 형상변화가 연소특성 및 배기배출물에 미치는 영향)

  • Kim, Tae-Woo;Cho, Seung-Wan;Chang, Young-June;Jeon, Chung-Hwan
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.314-319
    • /
    • 2005
  • In this study, the combustion characteristics were investigated with the variation of design factors on multiple slit gas burner. The design factors consist of slit height, width, spacing, and inner length. The combustion characteristics were made analysis of the CO emission and NOx emission by using CO analyzer and NOx analyzer. The lower perimeter to area and the narrow spacing extends the lift-flame limit. The CO emission increases with the increasing perimeter to area ratio at the same condition. The NOx emission is found to be less significant with the port perimeter to area ratio. The flame interference might highly depend on the spacing and port perimeter to area ratio, and it also affects the burner performance.

  • PDF