• Title/Summary/Keyword: Heating Device

Search Result 478, Processing Time 0.029 seconds

Simulation of Horizontal Thin-film Thermoelectric Cooler for the Mobile Electronics Thermal Management (모바일 전자기기의 열점 제어를 위한 수평형 박막 열전 냉각 소자의 모사 해석)

  • Park, Sangkug;Park, Hong-Bum;Joo, Young-Chang;Joo, Youngcheol
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.2
    • /
    • pp.17-21
    • /
    • 2017
  • Horizontal thin-film thermoelectric cooler has been simulated using a commercial software (ANSYS Workbench Thermal-electric). The thermoelectric cooler consists of thin-film n-type $Bi_2Te_3$, p-type $Sb_2Te_3$ thermoelectric elements, and Au electrode, respectively. The hot spot was placed under the center of device which represents Joule heating. Numerical analysis was conducted by geometric variable, and a maximum temperature difference of $13^{\circ}C$ was obtained. As from the simulation parameters, we presented an optimized design for high efficiency cooling.

Electrical/Mechanical Diagnosis of Local Deterioration in 600V Shielded Twist Pair Cable in a Nuclear Power Plant (원전용 600V 차폐 꼬임쌍선 케이블의 국부열화에 대한 전기적/기계적 진단)

  • Park, Myeongkoo;Kim, Kwangho;Lim, Chanwoo;Kim, TaeYoon;Kim, Hyunsu;Chai, Jangbom;Kim, Byungsung;Nah, Wansoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.203-210
    • /
    • 2017
  • In this paper, we propose a electrical/mechanical method to effectively diagnose the local deterioration of a 10m long power shielded twist pair cable defined by the American Wire Gauge (AWG) 14 specification using electrical/mechanical methods. The rapid deterioration of the cable proceeded by using the heating furnace, which is based on the Arrhenius equations proceeds from 0 to 35 years with the deteriorated equivalent model. In this paper, we introduce a method to diagnose the characteristics of locally deteriorated cable by using $S_{21}$ phase and frequency change rate measured by vector network analyzer which is the electrical diagnostic method. The measured $S_{21}$ phase and rate of change of frequency show a constant correlation with the number of years of locally deteriorated cable, thus it can be useful for diagnosing deteriorated cables. The change of modulus due to deterioration was measured by a modulus measuring device, which is defined by the ratio of deformation from the force externally applied to the cable, and the rate of modulus change also shows a constant correlation with the number of years of locally deteriorated cable. Finally, By combining the advantages of electrical/mechanical diagnostic methods, we can efficiently diagnose the local deterioration in the power shielded cable.

Examination on the Mounting Status of Cigar Lighter Receptacle for Vehicles and Analysis of its Tracking Characteristics (차량용 시가 잭의 장착 실태조사 및 트레킹 특성 분석)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.28-33
    • /
    • 2009
  • This study examined the mounting status of cigar lighter receptacles for vehicles and analyzed the tracking phenomenon that occurs when foreign material entered a cigar lighter receptacle to obtain data for the analysis of accident investigation. Regardless of the vehicle's output, cigar lighter receptacles are mounted in a vehicle horizontally, vertically, or at tilting or inclined angle. The tilting type cigar lighter receptacle is much easier to use but current leakage resulting from foreign materials (coffee, beverages, water, etc.) falling into the cigar lighter receptacle may cause a fire to start. This study used a vehicle battery (DC 12V) as a power supply for the tracking test and configured its circuit in the same way as that of an electrical device in a vehicle. The tracking phenomenon that occurred in the standby mode of the vehicle exhibited a fine flame and an irregular occurrence of smoke. While this tracking phenomenon was occurring, the leakage current and the reaching distance of the flame were measured to be approximately 930mA and $20{\sim}50cm$, respectively. It is thought that the resultant flame may ignite toluene, dust, cigarettes, etc. It was observed that as the tracking progressed, the internal metal socket melted and a hole was created, the surface of which was also severely carbonized. In addition, the electrical resistance of the carbonized conductive path was measured to be approximately $30{\Omega}$. It is thought that this much resistance may cause local heating when leakage current flows and could ignite any nearby flammable material.

Electrical and Material Characteristics of HfO2 Film in HfO2/Hf/Si MOS Structure (HfO2/Hf/Si MOS 구조에서 나타나는 HfO2 박막의 물성 및 전기적 특성)

  • Bae, Kun-Ho;Do, Seung-Woo;Lee, Jae-Sung;Lee, Yong-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.101-106
    • /
    • 2009
  • In this paper, Thin films of $HfO_2$/Hf were deposited on p-type wafer by Atomic Layer Deposition (ALD). We studied the electrical and material characteristics of $HfO_2$/Hf/Si MOS capacitor depending on thickness of Hf metal layer. $HfO_2$ films were deposited using TEMAH and $O_3$ at $350^{\circ}C$. Samples were then annealed using furnace heating to $500^{\circ}C$. Round-type MOS capacitors have been fabricated on Si substrates with $2000\;{\AA}$-thick Pt top electrodes. The composition rate of the dielectric material was analyzed using TEM (Transmission Electron Microscopy), XRD (X-ray Diffraction) and XPS (X-ray Photoelectron Spectroscopy). Also the capacitance-voltage (C-V), conductance-voltage (G-V), and current-voltage (I-V) characteristics were measured. We calculated the density of oxide trap charges and interface trap charges in our MOS device. At the interface between $HfO_2$ and Si, both Hf-Si and Hf-Si-O bonds were observed, instead of Si-O bond. The sandwiched Hf metal layer suppressed the growing of $SiO_x$ layer so that $HfSi_xO_y$ layer was achieved. And finally, the generation of both oxide trap charge and interface trap charge in $HfO_2$ film was reduced effectively by using Hf metal layer.

Analysis of the Characteristics of Flue Gas in Infrared Mobile Heaters for Gas Room Heating (가스난방용 적외선 히터의 연소배기가스 특성해석)

  • Kim Young-Gyu;Kwon Jeong-Rock;Kim Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.66-73
    • /
    • 1998
  • This paper deals with the combustion characteristics of flue gas in infared mobile heaters. The experimental work has been performed to obtain the concentration levels and combustion characteristics of flue gas with varying chamber size and room temperature. The experimental results showed that oxygen depletion sensor device was operated at the oxygen concentration level of $18.3\%$ for all the chamber size. The combustion characteristics of oxygen and carbon dioxide show a linearity After 10 minutes the combustion property of carbon monoxide occurs at random without a level of oxygen and carbon dioxide in closed space of the heater. In these results, it is very important to prevent incomplete combustion through a sufficient ventilation, and accident prevention with a reduction of the oxygen and diffusion of toxic carbon monoxide.

  • PDF

Fabrication and Evaluation Properties of Titanium Sintered-body for a Sputtering Target by Spark Plasma Sintering Process (방전플라즈마 소결 공정을 이용한 스퍼터링 타겟용 타이타늄 소결체 제조 및 특성 평가)

  • Lee, Seung-Min;Park, Hyun-Kuk;Youn, Hee-Jun;Yang, Jun-Mo;Woo, Kee-Do;Oh, Ik-Hyun
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.11
    • /
    • pp.845-852
    • /
    • 2011
  • The Spark Plasma Sintering(SPS) method offers a means of fabricating a sintered-body having high density without grain growth through short sintering time and a one-step process. A titanium compact having high density and purity was fabricated by the SPS process. It can be used to fabricate a Ti sputtering target with controlled parameters such as sintering temperature, heating rate, and pressure to establish the optimized processing conditions. The compact/target(?) has a diameter of ${\Phi}150{\times}6.35mm$. The density, purity, phase transformation, and microstructure of the Ti compact were analyzed by Archimedes, ICP, XRD and FE-SEM. A Ti thin-film fabricated on a $Si/SiO_2$ substrate by a sputtering device (SRN-100) was analyzed by XRD, TEM, and SIMS. Density and grain size were up to 99% and below $40{\mu}m$, respectively. The specific resistivity of the optimized Ti target was $8.63{\times}10^{-6}{\Omega}{\cdot}cm$.

A Study on the Performance Characteristics of a Heat Pump System using Stack Wast Heat in Fuel Cell Vehicles (스택 폐열을 이용한 연료전지 자동차용 열펌프 시스템의 성능 특성에 관한 연구)

  • Jeon, Byungyong;Ko, Wonbin;Park, Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.325-330
    • /
    • 2016
  • This study was conducted to develop a heating system for a fuel cell-driven electric vehicle. The system consists of a compressor, an expansion device and three heat exchangers. A conventional air source heat exchanger is used as primary heat exchanger of the system, and an additional water source heat exchanger is used as a pre-heater to supply heat to the upstream air of the primary heat exchanger. On the other hand, the third heat exchanger consists of a water-to-refrigerant heat exchanger. The heat source of the pre-heater and the water-refrigerant heat exchanger is the waste heat from the fuel cell's stack. In the experiment, the indoor and the outdoor air temperature were fixed, and the compressor speed, EEV opening and waste heat temperature were varied. The results indicate that the $COP_h$ of the proposed system is 3.01 when the system is operating at a 1,200 rpm compressor speed, 50% EEV opening, and $50^{\circ}C$ waste heat source temperature in air pre-heater operation. However, when the system uses a water-refrigerant heat exchanger, the $COP_h$ increases to up to 9.42 at the same compressor speed and waste heat source temperature with 75% EEV openings.

Precessional Motion of Ferromagnetic Pt/Co/Pt Thin Film with Perpendicular Magnetic Anisotropy (수직 자기 이방성을 갖는 Pt/Co/Pt 자성 박막의 세차 운동 측정 및 분석)

  • Yun, Sang-Jun;Lee, Jae-Chul;Choe, Sug-Bong;Shin, Kyoung-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.6
    • /
    • pp.204-207
    • /
    • 2011
  • We developed a time-resolved magneto-optical Kerr effect microscope system to investigate ultrafast magnetization dynamics. Based on the pump-probe method, 0.1-ps time resolution was achieved by use of a fs Ti:Sapphire laser. The magnetization dynamics was then measured on Pt/Co/Pt thin films with various Co thicknesses. All the samples exhibited ultrafast demagnetization within a few ps by direct heating of pump laser. Some thicker samples showed precessional motion of magnetization, from which the Gilbert damping constant was determined based on the Landau-Lifshitz-Gilbert equation.

Thermotherapy and Dynamic Warm-up on the Kinetic Parameters during Drop-landing (드롭랜딩 시 국소부위 온열처치와 동적 준비운동이 하지의 운동역학적 변인에 미치는 영향)

  • Kim, Sungmin;Song, Jooho;Han, Sanghyuk;Moon, Jeheon
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.297-307
    • /
    • 2021
  • Objective: The aim of this study was to analyze kinetic variables between thermotherapy and dynamic warm-up during drop-landing. Method: Twenty male healthy subjects (Age: 21.85 ± 1.90 years, Height: 1.81 ± 0.06 cm, Weight: 68.5 ± 7.06 kg) underwent three treatments applied on the thermotherapy of femoral muscles and a dynamic warm-up. The thermotherapy was performed for 15 minutes while sitting in a chair using an electric heating pad equipped with a temperature control device. Dynamic warm-up performed 14 exercise, a non-treatment was sitting in a chair for 15 minutes. Core temperature measurements of all subjects were performed before landing at a height of 50 cm. During drop-landing, core temperature, joint angle, moment, work of the sagittal plane was collected and analyzed. All analyses were performed with SPSS 21.0 and for repeated measured ANOVA and Post-hoc was Bonferroni. Results: Results indicated that Thermotherapy was increased temperature than other treatments (p = .000). During drop-landing, hip joint of dynamic warm-up was slower for angular velocity (p < .005), and left ankle joint was fastest than other treatments (p = .004). Maximum joint moment of dynamic warm-up was smaller for three joints (hip extension: p = .000; knee flexion/extension: p = .001/.000; ankle plantarflexion: p = .000). Negative work of dynamic warm-up was smaller than other treatments (p = .000). Conclusion: In conclusion, the thermotherapy in the local area doesn't affect the eccentric contraction of the thigh. The dynamic warm-up treatment minimized the joint moment and negative work of the lower joint during an eccentric contraction, it was confirmed that more active movement was performed than other treatment methods.

Emission of Airbone Pollutants from Traditional Korean Fireplace (아궁이 사용에 의한 대기오염물질의 배출 특성)

  • Park, Sung Kyu;Lyu, Kun Jung;Choi, Sang Jin;Kim, Dae keun;Kim, Dong Young;Jang, Young Kee
    • Journal of Climate Change Research
    • /
    • v.6 no.2
    • /
    • pp.113-119
    • /
    • 2015
  • Emission from the traditional Korean fireplace, or the under-floor heating and cooking device, can contribute significantly to airborne pollutants inventories. This study has systematically measured emissions of airborne pollutants from the fireplace when used different fuels such as firewood, agricultural crop residuals, household wastes. The results show that emission factors of airborne pollutants through the primary combustion of firewood were 3.22 g/kg for TSP, 2.93 g/kg for $PM_{10}$, 2.65 g/kg for $PM_{2.5}$, 174.19 g/kg for CO, 7.77 g/kg for NO, 0.15 g/kg for $SO_2$, 40.53 g/kg for TVOC and 0.03 g/kg for $NH_3$; from burning of agricultural crop residues, 2.85 g/kg for TSP, 1.38 g/kg for $PM_{10}$, 1.14 g/kg for $PM_{2.5}$, 126.47 g/kg for CO, 12.60 g/kg for NO, 0.20 g/kg for $SO_2$, 33.73 g/kg for TVOC and 0.02 g/kg for $NH_3$; and for household wastes, 10.52 g/kg for TSP, 8.52 g/kg for $PM_{10}$, 6.23 g/kg for $PM_{2.5}$, 72.86 g/kg for CO, 11.73 g/kg for NO, 0.20 g/kg for $SO_2$, 47.10 g/kg for TVOC and 0.20 g/kg for $NH_3$.